Combined quantitative analysis of attenuation corrected and non-corrected myocadial perfusion SPECT: Method development and clinical validation

被引:41
|
作者
Xu, Yuan [1 ,2 ]
Fish, Mathews [4 ]
Gerlach, James [1 ,2 ]
Lemley, Mark [4 ]
Berman, Daniel S. [1 ,2 ,3 ]
Germano, Guido [1 ,2 ,3 ]
Slomka, Piotr J. [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[4] Sacred Heart Med Ctr, Oregon Heart & Vasc Inst, Springfield, OR USA
基金
美国国家卫生研究院;
关键词
Single photon emission computed tomography; myocardial perfusion imaging; attenuation correction; total perfusion deficit; CORONARY-ARTERY-DISEASE; SIMPLIFIED NORMAL LIMITS; DIAGNOSTIC-ACCURACY; COMPUTED-TOMOGRAPHY; MULTICENTER TRIAL; QUANTIFICATION; IMPACT; EXTENT;
D O I
10.1007/s12350-010-9220-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Attenuation corrected myocardial perfusion SPECT (AC-MPS) has been demonstrated to improve the specificity of detecting coronary artery disease (CAD) by visual analysis which utilizes both non-corrected (NC) and AC data. However, the combined automated quantification of NC and AC-MPS has not been previously described. We aimed to develop a combined quantitative analysis from AC and NC data to improve the accuracy of automated detection of CAD from AC-MPS. Methods. Stress total perfusion deficit (TPD) values were generated by standard analysis for NC (NC-TPD), AC (AC-TPD) and by combined NC-AC analysis (NA-TPD), in which the hypoperfusion severity in each polar map location was defined as the average of AC and NC severity computed by comparison with separate AC and NC normal limits. Ischemic TPD was also calculated as the difference between stress TPD and rest TPD for each measure. Stress/rest Tc-99m sestamibi MPS studies in 650 patients with correlating coronary angiography and in 345 patients with a low-likelihood (LLk) of CAD were used to assess diagnostic performance of combined NC-AC analysis. Results. NA-TPD had a higher receiver-operator-characteristic area under the curve (ROC-AUC) (0.87) than NC-TPD (0.85; P<.01) or AC-TPD (0.85; P<.01) for detection of stenosis >= 70% in angiographic group. It also had higher specificity (75%) vs NC-TPD (65%; P<.0001), or AC-TPD (70%; P = .016). In LLk group, the normalcy rate of NA-TPD (95%) was higher than for NC-TPD (90%; P<.01) and similar to AC-TPD (94%; P = NS). NA-TPD had higher ROC-AUC than that for 17-segment expert visual scoring of stress scans in angiographic group (0.84; P = .01), comparable accuracy (81%) and similar normalcy rates (95% vs 97%; P = NS). Ischemic TPD by combined NC-AC analysis had higher ROC-AUC than that for any ischemic measure. Similar to stress NA-TPD, it also obtained the similar performance results as compared with ischemic TPD based on NC or AC and higher sensitivity (89% vs 85%; P = .0295) as compared with ischemic visual score in angiographic group. Conclusion. Combined NC-AC MPS quantification using either stress or ischemic TPD shows significant improvements for ROC-AUC and specificity of MPS in the detection of CAD compared with standard NC-MPS or AC-MPS and comparable performance to expert visual scoring. This technique may lead to an enhancement in a fully automated quantification for the perfusion analysis by AC-MPS. (J Nucl Cardiol 2010;17:591-9.)
引用
收藏
页码:591 / 599
页数:9
相关论文
共 12 条
  • [1] Combined quantitative analysis of attenuation corrected and non-corrected myocadial perfusion SPECT: Method development and clinical validation
    Yuan Xu
    Mathews Fish
    James Gerlach
    Mark Lemley
    Daniel S. Berman
    Guido Germano
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2010, 17 : 591 - 599
  • [2] Comparison of non-attenuation corrected and attenuation corrected myocardial perfusion SPECT
    Raza, Hasan
    Jadoon, Lubna Khan
    Mushtaq, Sumaira
    Jabeen, Aneeqa
    Maqbool, Minhaj
    Ul Ain, Musarrat
    Ahmed, Bashir
    Memon, Muhammad Ali
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2016, 47 (03): : 783 - 792
  • [3] Prospective clinical comparison of non-corrected and attenuation- and scatter-corrected myocardial perfusion SPECT in patients with suspicion of coronary artery disease
    Banzo, I
    Pena, FJ
    Allende, RH
    Quirce, R
    Carril, JM
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (09) : 995 - 1002
  • [4] Comparative Accuracy of CT Attenuation-Corrected and Non-Attenuation-Corrected SPECT Myocardial Perfusion Imaging
    Sharma, Punit
    Patel, Chetan D.
    Karunanithi, Sellam
    Maharjan, Sagar
    Malhotra, Arun
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (04) : 332 - 338
  • [5] Simplified normal limits and automated quantitative assessment for attenuation-corrected myocardial perfusion SPECT
    Piotr J. Slomka
    Hidetaka Nishina
    James Gerlach
    Daniel S. Berman
    Guido Germano
    Mathews B. Fish
    Santiago Lorenzo
    Journal of Nuclear Cardiology, 2006, 13 : 642 - 651
  • [6] Simplified normal limits and automated quantitative assessment for attenuation-corrected myocardial perfusion SPECT
    Slomka, Piotr J.
    Fish, Mathews B.
    Lorenzo, Santiago
    Nishina, Hidetaka
    Gerlach, James
    Berman, Daniel S.
    Germano, Guido
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (05) : 642 - 651
  • [7] CT-based attenuation correction in Tl-201 myocardial perfusion scintigraphy is less effective than non-corrected SPECT for risk stratification
    Savvopoulos, Christos A.
    Spyridonidis, Trifon
    Papandrianos, Nikolaos
    Vassilakos, Pavlos J.
    Alexopoulos, Dimitrios
    Apostolopoulos, Dimitris J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) : 519 - 531
  • [8] CT-based attenuation correction in Tl-201 myocardial perfusion scintigraphy is less effective than non-corrected SPECT for risk stratification
    Christos A. Savvopoulos
    Trifon Spyridonidis
    Nikolaos Papandrianos
    Pavlos J. Vassilakos
    Dimitrios Alexopoulos
    Dimitris J. Apostolopoulos
    Journal of Nuclear Cardiology, 2014, 21 : 519 - 531
  • [9] A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT introduced by misalignment between emission scan and CT-derived attenuation maps
    Fricke, H
    Fricke, E
    Weise, R
    Kammeier, A
    Lindner, O
    Burchert, W
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (10) : 1619 - 1625
  • [10] Combined supine and prone quantitative myocardial perfusion SPECT method development and clinical validation in patients with no known coronary artery disease
    Nishina, H
    Slomka, PJ
    Abidov, A
    Yoda, S
    Akincioglu, C
    Kang, XP
    Cohen, I
    Hayes, SW
    Friedman, JD
    Germano, G
    Berman, DS
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (01) : 51 - 58