GaAs x-ray detectors with sub-nanosecond temporal response

被引:12
|
作者
Looker, Quinn [1 ]
Wood, Michael G. [1 ]
Lake, Patrick W. [1 ]
Kim, Jin K. [1 ]
Serkland, Darwin K. [1 ]
机构
[1] Sandia Natl Labs, Albuquerque, NM 87123 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 11期
关键词
GALLIUM-ARSENIDE; ENERGY;
D O I
10.1063/1.5127294
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fast semiconductor radiation detectors operated in current mode provide a valuable diagnostic in pulsed power applications. Si detectors are common due to the availability of high-quality materials and mature fabrication processes, but they offer low absorption for hard x-rays above similar to 10 keV. GaAs can provide increased hard x-ray absorption for the same detector volume due to a higher atomic number. GaAs photodiodes have been produced from epitaxial material grown at Sandia National Laboratories and fabricated at Sandia's microfabrication facility. These detectors have significantly higher hard x-ray absorption (>10x at 15 keV) and nearly identical temporal impulse response to similarly sized Si detectors of 0.5 ns full-width half maximum. Published under license by AIP Publishing.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Developments in GaAs pixel detectors for X-ray imaging
    Bates, R
    Campbell, M
    Da Via, C
    Heijne, E
    Heuken, M
    Jurgensen, H
    Ludwig, J
    Manolopoulos, S
    Marder, D
    Mathieson, K
    O'Shea, V
    Raine, C
    Rogalla, M
    Smith, KM
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 534 - 540
  • [32] GaAs resistor structures for X-ray imaging detectors
    Ayzenshtat, GI
    Budnitsky, DL
    Koretskaya, OB
    Novikov, VA
    Okaevich, LS
    Potapov, AI
    Tolbanov, OP
    Tyazhev, AV
    Vorobiev, AP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 96 - 101
  • [33] Developments in GaAs pixel detectors for X-ray imaging
    Manolopoulos, S
    Bates, R
    Campbell, M
    Da Via, C
    Heijne, E
    Heuken, M
    Jurgensen, H
    Ludwig, J
    Marder, D
    Mathieson, K
    O'Shea, V
    Raine, C
    Rogalla, M
    Smith, KM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 394 - 400
  • [34] Deconvolving the temporal response of photoelectric x-ray detectors for the diagnosis of pulsed radiations
    Zou, Shiyang
    Song, Peng
    Guo, Liang
    Pei, Wenbing
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (09):
  • [35] X-ray response of epitaxial GaAs
    Owens, A
    Bavdaz, M
    Kraft, S
    Peacock, A
    Nenonen, S
    Andersson, H
    Gagliardi, MA
    Gagliardi, T
    Scholze, F
    Ulm, G
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (11) : 7522 - 7527
  • [36] Investigation of high-power sub-nanosecond GaAs photoconductive switches
    Shi, W
    Zhao, W
    Zhang, XB
    Li, EL
    ACTA PHYSICA SINICA, 2002, 51 (04) : 867 - 872
  • [37] Pulse response of GaAs and InP photoconductive detectors for the X-ray diagnostics of laser plasmas
    Riesz, F
    Ryc, L
    Badziak, J
    Pfeifer, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 474 (02): : 151 - 158
  • [38] Formation of Short Microwave Pulses by Laser-Driven GaAs Switch with Sub-Nanosecond Transient Response
    Denisov, Gregory G.
    Palitsin, Alexey, V
    Sobolev, Dmitriy, I
    Belousov, Vladimir, I
    Gorbunov, Ivan A.
    Kulagin, Oleg, V
    Morozov, Sergey, V
    Murzanev, Aleksey A.
    Stepanov, Andrey N.
    Glyavin, Mikhail Yu
    2021 46TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2021,
  • [39] Effect of the laser focus position on characteristics of X-ray and ion emission from gold plasmas generated by a sub-nanosecond laser
    Chaurasia, S.
    Munda, D. S.
    Tripathi, S.
    Gupta, N. K.
    Dhareshwar, L. J.
    Tallents, G. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (23-24): : 3611 - 3616
  • [40] Temporal artefacts in flat dynamic X-ray detectors
    Overdick, M
    Solf, T
    Wischmann, HA
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 47 - 58