Application of modified multiwall carbon nanotubes paste electrode for simultaneous voltammetric determination of morphine and diclofenac in biological and pharmaceutical samples

被引:220
作者
Mokhtari, Ali [2 ]
Karimi-Maleh, Hassan [1 ]
Ensafi, Ali A. [3 ]
Beitollahi, Hadi [4 ]
机构
[1] Islamic Azad Univ, Dept Chem, Sci & Res Branch, Mazandaran, Iran
[2] Golestan Univ, Dept Engn & Technol, Aliabad Katool, Iran
[3] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[4] Int Ctr Sci High Technol & Environm Sci, Dept Environm, Res Inst Environm Sci, Kerman, Iran
关键词
Morphine and diclofenac; Multiwall carbon nanotubes; Vinylferrocene; Voltammetric measurement; LIQUID-CHROMATOGRAPHIC DETERMINATION; CONTROLLED-RELEASE INDOMETHACIN; SEQUENTIAL INJECTION-ANALYSIS; PYROLYTIC-GRAPHITE ELECTRODE; CONTROLLED CLINICAL-TRIAL; SOLID-PHASE EXTRACTION; CHEMILUMINESCENCE DETECTION; FLUORESCENCE-DETECTION; SPECTROPHOTOMETRIC DETERMINATION; AMPEROMETRIC DETERMINATION;
D O I
10.1016/j.snb.2012.03.059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel modified carbon paste electrode with vinylferrocene/multiwall carbon nanotubes was fabricated. The electrochemical response of the modified electrode toward morphine was studied by means of cyclic voltammetry (CV), chronoamperometry (CA) and electrochemical impedance spectroscopy (EIS). The structural morphology of the modified electrode was characterized by SEM technique. The prepared electrode showed an excellent electrocatalytic activity in the oxidation of morphine, leading to remarkable enhancements in the corresponding peak currents and lowering the peak potential. Using square wave voltammetry (SWV), we could measure morphine and diclofenac in one mixture independently from each other by a potential difference of about 300 mV for the first time. Square wave voltammetric peaks current of morphine and diclofenac increased linearly with their concentrations in the ranges 01 0.2-250.0 mu mol L-1, and 5.0-600.0 mu mol L-1, respectively. The detection limits of 0.09 and 2.0 mu mol L-1 were achieved for morphine and diclofenac, respectively. The proposed voltammetric sensor was successfully applied to the determination of morphine and diclofenac in real samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 56 条
[1]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[2]   High-performance liquid chromatographic determination of diclofenac in human plasma after solid-phase extraction [J].
Arcelloni, C ;
Lanzi, R ;
Pedercini, S ;
Molteni, G ;
Fermo, I ;
Pontiroli, A ;
Paroni, R .
JOURNAL OF CHROMATOGRAPHY B, 2001, 763 (1-2) :195-200
[3]  
Barnett NW, 1996, FRESEN J ANAL CHEM, V355, P591
[4]   Determination of morphine in water immiscible process streams using sequential injection analysis coupled with acidic permanganate chemiluminescence detection [J].
Barnett, NW ;
Lenehan, CE ;
Lewis, SW ;
Tucker, DJ ;
Essery, KM .
ANALYST, 1998, 123 (04) :601-605
[5]   Carbon nanotubes - the route toward applications [J].
Baughman, RH ;
Zakhidov, AA ;
de Heer, WA .
SCIENCE, 2002, 297 (5582) :787-792
[6]   Fabrication of a nanostructure-based electrochemical sensor for simultaneous determination of N-acetylcysteine and acetaminophen [J].
Beitollahi, Hadi ;
Raoof, Jahan-Bakhsh ;
Hosseinzadeh, Rahman .
TALANTA, 2011, 85 (04) :2128-2134
[7]   Nanomolar and Selective Determination of Epinephrine in the Presence of Norepinephrine Using Carbon Paste Electrode Modified with Carbon Nanotubes and Novel 2-(4-Oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl-hydrazinecarbothioamide [J].
Beitollahi, Hadi ;
Karimi-Maleh, Hassan ;
Khabazzadeh, Hojatollah .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9848-9851
[8]   MORPHINE DETERMINATION BY GAS-CHROMATOGRAPHY MASS-SPECTROSCOPY IN HUMAN VITREOUS-HUMOR AND COMPARISON WITH RADIOIMMUNOASSAY [J].
BERMEJO, AM ;
RAMOS, I ;
FERNANDEZ, P ;
LOPEZRIVADULLA, M ;
CRUZ, A ;
CHIAROTTI, M ;
FUCCI, N ;
MARSILLI, R .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (06) :372-374
[9]   Voltammetric response of diclofenac-molecularly imprinted film modified carbon electrodes [J].
Blanco-López, MC ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (02) :257-261
[10]   Sensitive capillary gas chromatographic mass spectrometric selected ion monitoring method for the determination of diclofenac concentrations in human plasma [J].
Borenstein, MR ;
Xue, YZ ;
Cooper, S ;
Tzeng, TB .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 685 (01) :59-66