Improvement of the imaging resolution for a Compton Camera by determination of the interaction depth in a 25-segmented germanium detector

被引:0
作者
Jung, Hyo Soon [1 ]
Lee, Ju Hahn [1 ]
Kwon, Young Kwan [1 ]
Seo, Hee [2 ]
Kim, Chan Hyeong [2 ]
Lee, Chun Sik [1 ]
机构
[1] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
[2] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
The imaging resolution in a Compton camera depends mainly on the position uncertainty, which is affected by the size of electrodes in a detector. Therefore, if any other method is not used for the reduction of the position uncertainty, the imaging resolution is limited by the size of electrodes. Recently, we have developed a Compton camera consisting of a double-sided silicon strip detector (DSSD) and a 25-segmented germanium detector (25-SEGD). The 25-SEGD has an active volume of 5 x 5 x 2 cm(3). We have performed measurement for determination of the interaction depth in the 25-SEGD using the pulse shape analysis. After getting a rise-time correlation between the anode and the segment, we obtained a relation formula between the rise-time of the detector signal and the depth derived from the decay equation of gamma-ray in the detector. This decay formula has been used for the determination of interaction depth. As a result of applying the relation function to image reconstruction, we could improve the imaging resolution.
引用
收藏
页码:4364 / +
页数:2
相关论文
共 6 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
Cho HY, 2004, J KOREAN PHYS SOC, V45, P1485
[3]  
DOGAN N, 2004, NUCL INSTRUM METH A, V345, P296
[4]  
ROGERS WL, 2001, COMPTON CAMERA NUCL
[5]   Lessons learnt from COMPTEL for future telescopes [J].
Schönfelder, V .
NEW ASTRONOMY REVIEWS, 2004, 48 (1-4) :193-198
[6]   PROPOSED GAMMA CAMERA [J].
TODD, RW ;
NIGHTINGALE, JM ;
EVERETT, DB .
NATURE, 1974, 251 (5471) :132-134