Accuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature

被引:219
作者
D'haese, Jan [1 ,2 ]
Van De Velde, Tommie [2 ]
Komiyama, Ai [3 ]
Hultin, Margaretha [3 ]
De Bruyn, Hugo [2 ]
机构
[1] Tandklin Sint Lievens Houtem, B-9520 Sint Lievens Houtem, Belgium
[2] Univ Ghent, Sch Dent, Fac Med & Hlth Sci, Dept Periodontol & Oral Implantol, B-9000 Ghent, Belgium
[3] Karolinska Inst, Div Periodontol, Dept Dent Med, Huddinge, Sweden
关键词
accuracy; complications; dental implants; guided surgery; stereolithography; surgical template; PREDICTABLE PROSTHETIC OUTCOMES; ENSURE PRECISE PLACEMENT; DRILLING GUIDES; PLANNING SYSTEM; CT; TEMPLATE; SURGERY; MAXILLA; TOMOGRAPHY; ABUTMENTS;
D O I
10.1111/j.1708-8208.2010.00275.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting. Purpose: To review data on accuracy and surgical and prosthodontical complications using stereolithographical surgical guides for implant rehabilitation. Material and Methods: PubMed database was searched using the following keywords: three dimensional imaging,image based surgery,flapless guided surgery,customized drill guides,computer assisted surgery,surgical template, and stereolithography. Only papers in English were selected. Additional references found through reading of selected papers completed the list. Results: In total 31 papers were selected. Ten reported deviations between the preoperative implant planning and the postoperative implant locations. One in vitro study reported a mean apical deviation of 1.0 mm, three ex vivo studies a mean apical deviation ranging between 0.6 and 1.2 mm. In six in vivo studies an apical deviation between 0.95 and 4.5 mm was found. Six papers reported on complications mounting to 42% of the cases when stereolithographic guided surgery was combined with immediate loading. Conclusion: Substantial deviations in three-dimensional directions are found between virtual planning and actually obtained implant position. This finding and additionally reported postsurgical complications leads to the conclusion that care should be taken whenever applying this technique on a routine basis.
引用
收藏
页码:321 / 335
页数:15
相关论文
共 53 条
[1]   Implant Placement Accuracy When Using Stereolithographic Template as a Surgical Guide: Preliminary Results [J].
Al-Harbi, Saad A. ;
Sun, Albert Y. T. .
IMPLANT DENTISTRY, 2009, 18 (01) :46-51
[2]   OSSEOINTEGRATED ORAL IMPLANTS - A SWEDISH MULTICENTER STUDY OF 8139 CONSECUTIVELY INSERTED NOBELPHARMA IMPLANTS [J].
ALBREKTSSON, T ;
DAHL, E ;
ENBOM, L ;
ENGEVALL, S ;
ENGQUIST, B ;
ERIKSSON, AR ;
FELDMANN, G ;
FREIBERG, N ;
GLANTZ, PO ;
KJELLMAN, O ;
KRISTERSSON, L ;
KVINT, S ;
KONDELL, PA ;
PALMQUIST, J ;
WERNDAHL, L ;
ASTRAND, P .
JOURNAL OF PERIODONTOLOGY, 1988, 59 (05) :287-296
[3]  
Almog Dov M, 2006, J Oral Implantol, V32, P77, DOI 10.1563/789.1
[4]   Using computer-guided implantology in flapless implant surgery of a maxilla: a clinical report [J].
Azari, A. ;
Nikzad, S. ;
Kabiri, A. .
JOURNAL OF ORAL REHABILITATION, 2008, 35 (09) :690-694
[5]   Guided implant placement and immediate prosthesis delivery using traditional Branemark System abutments: A pilot study of 23 patients [J].
Balshi, Stephen F. ;
Wolfinger, Glenn J. ;
Balshi, Thomas J. .
IMPLANT DENTISTRY, 2008, 17 (02) :128-131
[6]  
Basten C H, 1995, Quintessence Int, V26, P609
[7]   A model study on flapless implant placement by clinicians with a different experience level in implant surgery [J].
de Velde, Tommie Van ;
Glor, Fadi ;
De Bruyn, Hugo .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) :66-72
[8]  
Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
[9]  
Fortin T, 2006, INT J ORAL MAX IMPL, V21, P298
[10]  
Fortin T, 2000, J Oral Implantol, V26, P300, DOI 10.1563/1548-1336(2000)026<0300:PDIPIB>2.3.CO