摘要
The capabilities of three solid chelating reagents were compared for the preconcentration of lead and mercury in high salinity aqueous samples (sea waters). The tested materials were 7-(4-ethyl-1-methyloctyl)-8-hydroxiquinoline (Kelex 100) adsorbed on Bondapack C18 (Kelex-100/C18), 8-hydroxiquinoline immobilized on vinyl co-polymer Toyopearl gel (TSK) and the commercial polystyrene/DVB ion exchange resin with paired iminodiacetate groups (Chelex-100). The two metals preconcentration and final determination were carried out in a flow injection system, coupled on-line to an atomic absorption spectrometric detector. Analytes were preconcentrated in the minicolumn, packed with the materials under investigation, while elution was achieved by injection of 500 mul of an adequate mineral acid solution. The different packing materials and minicolumn designs have been evaluated in terms of sensitivity for simultaneous preconcentration of both metals in sea water. Regarding the solid support, the best results were obtained for the TSK solid phase. Concerning the minicolumn design, the behavior was different for lead and mercury. Lead was quantitatively eluted with 0.5 M HCl and best performance was achieved when packing the solid material in a minicolumn with relatively small volume (1 cm length and 2.5 mm i.d.). In the case of mercury, bigger minicolumn volumes (5.5 cm length and 5.0 mm i.d.) and mixtures, 2 M HCl + 1 M HNO3, were required for its quantitative recovery and elution. The system has been evaluated for quantitative determination of the two metals under study in different Asturian coastal aqueous samples. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1071 / 1078
页数:8
相关论文
共 50 条
  • [1] On-line preconcentration system for determination of lead in water and sediment samples by flow injection-flame atomic absorption spectrometry
    Soylak, M
    Elci, L
    Akkaya, Y
    Dogan, M
    ANALYTICAL LETTERS, 2002, 35 (03) : 487 - 499
  • [2] Automated flow injection system for the preconcentration of bismuth and lead from acid solutions of alloys and determination by electrothermal atomic absorption spectrometry
    Giacomelli, MBO
    Ganzarolli, EM
    Curtius, AJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (05) : 525 - 533
  • [3] Fully automatic on-line separation preconcentration system for electrothermal atomic absorption spectrometry: Determination of cadmium and lead in sea-water.
    Fernandez, FM
    Stripeikis, JD
    Tudino, MB
    Troccoli, OE
    ANALYST, 1997, 122 (07) : 679 - 684
  • [4] Flow injection atomic absorption spectrometry manifold for lead determination in seawater.
    Tilves, MDH
    Nápoles, CD
    Nodarse, IC
    AFINIDAD, 2003, 60 (508) : 525 - 528
  • [5] Determination of mercury with a flow injection quartz tube atomic absorption spectrometry
    Xie, WB
    Wang, C
    Guo, PR
    Yao, JY
    Ying, ZL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (12) : 1466 - 1468
  • [6] A Flow Injection On-Line Unequal Flow Complexation Preconcentration Procedure Coupled with Flame Atomic Absorption Spectrometry for Determination of Lead in Tap Water
    Wang Zhong-yuan
    Su Yao-dong
    Li Shuang
    Gan Li-hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (11) : 2695 - 2698
  • [7] Simultaneous flow injection preconcentration of lead and cadmium using cloud point extraction and determination by atomic absorption spectrometry
    Silva, Edson Luiz
    Roldan, Paulo dos Santos
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (01) : 142 - 147
  • [8] Design of a field flow preconcentration system for cadmium determination in seawater by flow-injection-atomic absorption spectrometry
    Yebra, MC
    García, A
    Carro, N
    Moreno-Cid, A
    Puig, L
    TALANTA, 2002, 56 (04) : 777 - 785
  • [9] Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry
    Leal, L. O.
    Elsholz, O.
    Forteza, R.
    Cerda, V.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 399 - 405
  • [10] Flow-injection preconcentration and electrothermal atomic absorption spectrometry determination of manganese in seawater
    Sarzanini, C
    Abollino, O
    Mentasti, E
    ANALYTICA CHIMICA ACTA, 2001, 435 (02) : 343 - 350