Accuracy of CT angiography in the assessment of the circle of Willis: comparison of volume-rendered images and digital subtraction angiography

被引:37
作者
Han, Ari [1 ]
Yoon, Dae Young [1 ]
Chang, Suk Ki [1 ]
Lim, Kyoung Ja [1 ,2 ]
Cho, Byung-Moon [3 ]
Shin, Yoon Cheol [4 ]
Kim, Sam Soo [2 ]
Kim, Keon Ha [5 ]
机构
[1] Hallym Univ, Kangdong Seong Sim Hosp, Dept Radiol, Coll Med, Seoul, South Korea
[2] Kangwon Natl Univ, Dept Radiol, Coll Med, Chunchon, Kangwon Do, South Korea
[3] Hallym Univ, Coll Med, Kangdong Seong Sim Hosp, Dept Neurosurg, Seoul, South Korea
[4] Hallym Univ, Coll Med, Kangdong Seong Sim Hosp, Dept Thorac Surg, Seoul, South Korea
[5] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Coll Med, Seoul, South Korea
关键词
Vascular; brain; CT angiography; digital subtraction angiography; circle of Willis; anatomic variation; INDUCED SIGNAL LOSS; MR-ANGIOGRAPHY; CEREBRAL-ANGIOGRAPHY; CONVENTIONAL ANGIOGRAPHY; SUBARACHNOID HEMORRHAGE; STENOOCCLUSIVE-DISEASE; ARTERY; FLOW; RISK;
D O I
10.1258/ar.2011.110223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed tomography angiography (CTA) is increasingly used for non-invasive imaging of the cerebrovascular diseases. Purpose: To evaluate the accuracy of CTA in the assessment of the variation of the segment calibers of the circle of Willis. Material and Methods: One hundred and 17 patients with acute SAH (51 men and 66 women, mean age 50.9 years) who underwent CTA using a 16 detector-row CT scanner and DSA were evaluated retrospectively. The CTA and DSA studies were performed within 24 h after the onset of symptoms and within 24 h of each other. A total of 819 arterial segments (A-comA, right and left A1 segment, right and left P-corn A, and right and left P1 segment) of the circle of Willis were determined to be aplastic (grade 1), hypoplastic (grade 2), or normal-sized (grade 3) by blinded observers evaluating CIA volume-rendered images. The CIA results were then compared with findings on the corresponding DSA images (reference standard). Results: The overall agreement between CTA and DSA was 92.4%. We had 62 (7.6%) cases of disagreement (58 cases of under-estimation and four cases of over-estimation by CTA) between tow modalities. The sensitivity and specificity of CIA in the detection of aplastic and normal-sized segments were more than 90%. In contrast, subgroup analysis of the hypoplastic segments showed a sensitivity of 52.6% and a specificity of 98.2%. Conclusion: CIA is highly accurate in the assessment of anatomical variations of the circle of Willis; however, its sensitivity is limited in depicting hypoplastic segments.
引用
收藏
页码:889 / 893
页数:5
相关论文
共 50 条
[21]   CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms.: An experimental study [J].
Piotin, M ;
Gailloud, P ;
Bidaut, L ;
Mandai, S ;
Muster, M ;
Moret, J ;
Rüfenacht, DA .
NEURORADIOLOGY, 2003, 45 (06) :404-409
[22]   CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study [J].
M. Piotin ;
P. Gailloud ;
L. Bidaut ;
S. Mandai ;
M. Muster ;
J. Moret ;
D. A. Rüfenacht .
Neuroradiology, 2003, 45 :404-409
[23]   Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography [J].
Qi Li ;
Fajin Lv ;
Yongmei Li ;
Kewei Li ;
Tianyou Luo ;
Peng Xie .
European Radiology, 2009, 19 :2261-2267
[24]   Detection of carotid artery stenosis using histological specimens: a comparison of CT angiography, magnetic resonance angiography, digital subtraction angiography and Doppler ultrasonography [J].
David Netuka ;
Tomáš Belšán ;
Karolina Broulíková ;
Václav Mandys ;
František Charvát ;
Josef Malík ;
Lucie Coufalová ;
Ondřej Bradáč ;
Svatopluk Ostrý ;
Vladimír Beneš .
Acta Neurochirurgica, 2016, 158 :1505-1514
[25]   Detection of carotid artery stenosis using histological specimens: a comparison of CT angiography, magnetic resonance angiography, digital subtraction angiography and Doppler ultrasonography [J].
Netuka, David ;
Belsan, Tomas ;
Broulikova, Karolina ;
Mandys, Vaclav ;
Charvat, Frantisek ;
Malik, Josef ;
Coufalova, Lucie ;
Bradac, Ondrej ;
Ostry, Svatopluk ;
Benes, Vladimir .
ACTA NEUROCHIRURGICA, 2016, 158 (08) :1505-1514
[26]   320-Detector row CT angiography for detection and evaluation of intracranial aneurysms: Comparison with conventional digital subtraction angiography [J].
Wang, H. ;
Li, W. ;
He, H. ;
Luo, L. ;
Chen, C. ;
Guo, Y. .
CLINICAL RADIOLOGY, 2013, 68 (01) :E15-E20
[27]   Agreement between CT-Angiography and Digital Subtraction Angiography in Predicting Angiographic Vasospasm in Patients with Subarachnoid Hemorrhage [J].
Moser, Miriam M. ;
Gramss, Leon ;
Marik, Wolfgang ;
Weber, Michael ;
Hirschmann, Dorian ;
Wang, Wei-Te ;
Dodier, Philippe ;
Kasprian, Gregor ;
Bavinzski, Gerhard ;
Roessler, Karl ;
Hosmann, Arthur .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
[28]   A comparison of digital subtraction angiography and computed tomography angiography for the diagnosis of penetrating cerebrovascular injury [J].
Ares, William J. ;
Jankowitz, Brian T. ;
Tonetti, Daniel A. ;
Gross, Bradley A. ;
Grandhi, Ramesh .
NEUROSURGICAL FOCUS, 2019, 47 (05)
[29]   Comparison Between CTA and Digital Subtraction Angiography in the Diagnosis of Ruptured Aneurysms [J].
Philipp, Lucas R. ;
McCracken, D. Jay ;
McCracken, Courtney E. ;
Halani, Sameer H. ;
Lovasik, Brendan P. ;
Salehani, Arsalaan A. ;
Boulter, Jason H. ;
Cawley, C. Michael ;
Grossberg, Jonathan A. ;
Barrow, Daniel L. ;
Pradilla, Gustavo .
NEUROSURGERY, 2017, 80 (05) :769-777
[30]   Use of digital subtraction angiography for assessment of digital replantation [J].
Liuhong WANG Guangqiang ZHANG Department of Radiology the Second Affiliated Hospital School of Medicine Zhejiang University Hangzhou China .
Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2012, (03) :209-212