Accuracy of CT angiography in the assessment of the circle of Willis: comparison of volume-rendered images and digital subtraction angiography

被引:37
|
作者
Han, Ari [1 ]
Yoon, Dae Young [1 ]
Chang, Suk Ki [1 ]
Lim, Kyoung Ja [1 ,2 ]
Cho, Byung-Moon [3 ]
Shin, Yoon Cheol [4 ]
Kim, Sam Soo [2 ]
Kim, Keon Ha [5 ]
机构
[1] Hallym Univ, Kangdong Seong Sim Hosp, Dept Radiol, Coll Med, Seoul, South Korea
[2] Kangwon Natl Univ, Dept Radiol, Coll Med, Chunchon, Kangwon Do, South Korea
[3] Hallym Univ, Coll Med, Kangdong Seong Sim Hosp, Dept Neurosurg, Seoul, South Korea
[4] Hallym Univ, Coll Med, Kangdong Seong Sim Hosp, Dept Thorac Surg, Seoul, South Korea
[5] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Coll Med, Seoul, South Korea
关键词
Vascular; brain; CT angiography; digital subtraction angiography; circle of Willis; anatomic variation; INDUCED SIGNAL LOSS; MR-ANGIOGRAPHY; CEREBRAL-ANGIOGRAPHY; CONVENTIONAL ANGIOGRAPHY; SUBARACHNOID HEMORRHAGE; STENOOCCLUSIVE-DISEASE; ARTERY; FLOW; RISK;
D O I
10.1258/ar.2011.110223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed tomography angiography (CTA) is increasingly used for non-invasive imaging of the cerebrovascular diseases. Purpose: To evaluate the accuracy of CTA in the assessment of the variation of the segment calibers of the circle of Willis. Material and Methods: One hundred and 17 patients with acute SAH (51 men and 66 women, mean age 50.9 years) who underwent CTA using a 16 detector-row CT scanner and DSA were evaluated retrospectively. The CTA and DSA studies were performed within 24 h after the onset of symptoms and within 24 h of each other. A total of 819 arterial segments (A-comA, right and left A1 segment, right and left P-corn A, and right and left P1 segment) of the circle of Willis were determined to be aplastic (grade 1), hypoplastic (grade 2), or normal-sized (grade 3) by blinded observers evaluating CIA volume-rendered images. The CIA results were then compared with findings on the corresponding DSA images (reference standard). Results: The overall agreement between CTA and DSA was 92.4%. We had 62 (7.6%) cases of disagreement (58 cases of under-estimation and four cases of over-estimation by CTA) between tow modalities. The sensitivity and specificity of CIA in the detection of aplastic and normal-sized segments were more than 90%. In contrast, subgroup analysis of the hypoplastic segments showed a sensitivity of 52.6% and a specificity of 98.2%. Conclusion: CIA is highly accurate in the assessment of anatomical variations of the circle of Willis; however, its sensitivity is limited in depicting hypoplastic segments.
引用
收藏
页码:889 / 893
页数:5
相关论文
共 50 条
  • [1] Multidetector row CT angiography of the lower limb arteries: a prospective comparison of volume-rendered techniques and intra-arterial digital subtraction angiography
    Edwards, AJ
    Wells, IP
    Roobottom, CA
    CLINICAL RADIOLOGY, 2005, 60 (01) : 85 - 95
  • [2] Assessment of the Circle of Willis with Cranial Tomography Angiography
    Karatas, Ayse
    Coban, Gokmen
    Cinar, Celal
    Oran, Ismail
    Uz, Aysun
    MEDICAL SCIENCE MONITOR, 2015, 21 : 2647 - 2652
  • [3] Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs
    An, Soyon
    Hwang, Gunha
    Kim, Rakhoon
    Hwang, Tae Sung
    Lee, Hee Chun
    JOURNAL OF VETERINARY SCIENCE, 2023, 24 (05)
  • [4] Demographic age-related variation in Circle of Willis completeness assessed by digital subtraction angiography
    Eaton, Ryan G.
    Shah, Varun S.
    Dornbos, David, III
    Zaninovich, Orel A.
    Wenger, Nicole
    Dumont, Travis M.
    Powers, Ciaran J.
    BRAIN CIRCULATION, 2020, 6 (01) : 31 - 37
  • [5] Comparing the Accuracy of Digital Subtraction Angiography, CT Angiography and MR Angiography at Estimating the Volume of Cerebral Aneurysms
    Hanley, M.
    Zenzen, W. J.
    Brown, M. D.
    Gaughen, J. R.
    Evans, A. J.
    INTERVENTIONAL NEURORADIOLOGY, 2008, 14 (02): : 173 - 177
  • [6] A multidetector CT angiography study of variations in the circle of Willis in a Chinese population
    Li, Qi
    Li, Jialun
    Lv, Fajin
    Li, Kewei
    Luo, Tianyou
    Xie, Peng
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (03) : 379 - 383
  • [7] Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography
    Lu, Li
    Zhang, Long Jiang
    Poon, Colin S.
    Wu, Sheng Yong
    Zhou, Chang Sheng
    Luo, Song
    Wang, Mei
    Lu, Guang Ming
    RADIOLOGY, 2012, 262 (02) : 605 - 612
  • [8] Comparison of CT Perfusion and Digital Subtraction Angiography in the Evaluation of Delayed Cerebral Ischemia
    Killeen, Ronan P.
    Mushlin, Alvin I.
    Johnson, Carl E.
    Comunale, Joseph P.
    Tsiouris, Apostolos John
    Delaney, Holly
    Dunning, Allison
    Sanelli, Pina C.
    ACADEMIC RADIOLOGY, 2011, 18 (09) : 1094 - 1100
  • [9] Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms
    Luo, Zhuren
    Wang, Dan
    Sun, Xilin
    Zhang, Tong
    Liu, Fang
    Dong, Dandan
    Chan, Nicholas K.
    Shen, Baozhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 118 - 122
  • [10] Usefulness of CT angiography for characterizing cerebral arteriovenous malformations presenting as hemorrhage: comparison with digital subtraction angiography
    Zwanzger, C.
    Lopez-Rueda, A.
    Campodonico, D.
    Rosati, S.
    Blasco, J.
    San Roman, L.
    Macho, J.
    RADIOLOGIA, 2020, 62 (05): : 392 - 399