Percutaneous arteriovenous fistula creation with the 4F WavelinQ EndoAVF System

被引:21
作者
Berland, Todd [1 ]
Clement, Jason [2 ]
Inston, Nicholas [3 ]
Kreienberg, Paul [4 ,5 ]
Ouriel, Kenneth [6 ]
机构
[1] NYU, Div Vasc Surg, Med Ctr, New York, NY 10016 USA
[2] St Pauls Hosp, Dept Radiol, Vancouver, BC, Canada
[3] Queen Elizabeth Hosp Birmingham, Dept Nephrol & Kidney Transplantat, Birmingham, W Midlands, England
[4] Albany Med Coll, Albany Med Ctr Hosp, Dept Surg, Inst Vasc Hlth & Dis,Vasc Grp, Albany, NY 12208 USA
[5] Albany Med Coll, Albany Med Ctr Hosp, Div Vasc Surg, Albany, NY 12208 USA
[6] Syntactx, New York, NY USA
关键词
Hemodialysis; Chronic kidney disease; Arteriovenous fistula; Percutaneous; EndoAVF; HEMODIALYSIS; ACCESS; OUTCOMES; PATENCY; COMPLICATIONS; MULTICENTER; MATURATION; ELLIPSYS;
D O I
10.1016/j.jvs.2021.09.025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Percutaneous devices for creation of native arteriovenous fistulae offer an alternative to traditional open surgical techniques. The 4F WavelinQ EndoAVF System was developed as a lower profile alternative to facilitate access through smaller vessels and minimize access site complications; The current report is the original first experience of this device, assessing outcome in 120 patients followed for 6 months. Methods: The use of the 4F WavelinQ system in three studies, EASE (32 patients), EASE-2 (24 patients), and the EU postmarket clinical follow-up study (64 patients) was aggregated and analyzed. Patients were followed with duplex ultrasound at discharge and follow-up visits at 1, 3, and 6 months. Primary, assisted primary, and secondary patency rates were evaluated as Kaplan-Meier estimates and standard errors. Time to maturity and time to successful cannulation were defined as the mean 6 standard deviation days from the procedure in patients enrolled on dialysis. Results: Procedural success was achieved in 116 patients (96.7%). Primary, assisted-primary, and secondary 6-month patency rates were 71.9% +/- 4.5%, 80.7% +/- 4.1%, and 87.8% +/- 3.3%, respectively. Time to maturity averaged 41 +/- 17 days. Time to successful cannulation averaged 68 +/- 51 days. Device-related serious adverse events were reported in 3 of 120 patients (2.5%) and procedure-related serious adverse events occurred in 7 of 120 patients (5.8%). Arterial or venous access complications were not reported in any of the patients. Access circuit reinterventions were performed in 23 patients (19.2%), split between those performed for EndoAVF maturation (13/120 [10.8%]) and maintenance (11/120 [9.2%]). Conclusions: Percutaneous creation of native dialysis fistulae with the 4F WavelinQ EndoAVF System is safe and effective, with favorable durability and a low rate of serious complications and reinterventions through 6-month follow-up. Use of the 4F device allows for percutaneous fistula creation between the radial artery and radial vein or the ulnar artery and ulnar vein. These findings suggest that the 4F device is a useful percutaneous alternative to open surgical AVF or endovascular AVF with larger bore devices.
引用
收藏
页码:1038 / +
页数:12
相关论文
共 31 条
[21]   Promises for the future: minimally invasive fistula creation [J].
Rajan, Dheeraj K. ;
Lok, Charmaine E. .
JOURNAL OF VASCULAR ACCESS, 2015, 16 :S40-S41
[22]   Percutaneous Creation of an Arteriovenous Fistula for Hemodialysis Access [J].
Rajan, Dheeraj K. ;
Ebner, Adrian ;
Desai, Sudhen B. ;
Rios, Jesus M. ;
Cohn, William E. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (04) :484-490
[23]   Associations between Hemodialysis Access Type and Clinical Outcomes: A Systematic Review [J].
Ravani, Pietro ;
Palmer, Suetonia C. ;
Oliver, Matthew J. ;
Quinn, Robert R. ;
MacRae, Jennifer M. ;
Tai, Davina J. ;
Pannu, Neesh I. ;
Thomas, Chandra ;
Hemmelgarn, Brenda R. ;
Craig, Jonathan C. ;
Manns, Braden ;
Tonelli, Marcello ;
Strippoli, Giovanni F. M. ;
James, Matthew T. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 24 (03) :465-473
[24]   Hemodialysis arteriovenous fistula maturity: US evaluation [J].
Robbin, ML ;
Chamberlain, NE ;
Lockhart, ME ;
Gallichio, MH ;
Young, CJ ;
Deierhoi, MH ;
Allon, M .
RADIOLOGY, 2002, 225 (01) :59-64
[25]   Comparison of Outcomes of Percutaneous Arteriovenous Fistulae Creation by Ellipsys and WavelinQ Devices [J].
Shahverdyan, Robert ;
Beathard, Gerald ;
Mushtaq, Nasir ;
Litchfield, Terry F. ;
Nelson, Peter R. ;
Jennings, William C. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (09) :1365-1372
[26]   Recommended standards for reports dealing with arteriovenous hemodialysis accesses [J].
Sidawy, AN ;
Gray, R ;
Besarab, A ;
Henry, M ;
Ascher, E ;
Silva, M ;
Miller, A ;
Scher, L ;
Trerotola, S ;
Gregory, RT ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (03) :603-610
[27]   Initial 6-month quality review of a percutaneous endovascular arteriovenous fistula program [J].
Sultan, Sulaiman ;
Langsfeld, Mark ;
Chavez, LeAnn ;
Fabre, Anna ;
Osofsky, Robin ;
Argyropoulos, Christos ;
Owen, Jonathan G. .
JOURNAL OF VASCULAR ACCESS, 2021, 22 (04) :540-546
[28]   Hemodialysis vascular access: everything you always wanted to know about it (but were afraid to ask) [J].
Torreggiani, Massimo ;
Scaramuzzi, Maria Lucia ;
Manini, Alessandra ;
Castoldi, Francesca ;
Serpieri, Nicoletta ;
Maggi, Noemi ;
Sileno, Giuseppe ;
Migotto, Clara ;
Esposito, Vittoria ;
Montagna, Francesca ;
Esposito, Ciro .
JOURNAL OF NEPHROLOGY, 2013, 26 (05) :836-847
[29]   A systematic review, meta-analysis, and meta-regression of the efficacy and safety of endovascular arteriovenous fistula creation [J].
Wee, Ian Jun Yan ;
Yap, Hao Yun ;
Tang, Tjun Yip ;
Chong, Tze Tec .
JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) :309-+
[30]   Factors affecting patency of arteriovenous fistula following first percutaneous transluminal angioplasty [J].
Yap, Yit-Sheung ;
Chi, Wen-Che ;
Lin, Cheng-Hao ;
Liu, Yi-Chun ;
Wu, Yi-Wen ;
Yang, Hui-Yueh .
CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2021, 25 (01) :80-86