Chemiluminescence detection of paracetamol by a luminol-permanganate based reaction

被引:188
作者
Easwaramoorthy, D
Yu, YC
Huang, HJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 804, Taiwan
[2] Crescent Engn Coll, Dept Chem, Chennai 600048, India
关键词
paracetamol; luminol-permanganate; chemiluminescence; inhibition effect;
D O I
10.1016/S0003-2670(01)00968-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The flow injection analysis of paracetamol was developed based on its inhibitory effect on a luminol-permanganate chemiluminescence system. With a system containing solutions of 2.5 mM luminol, 5.0 muM KMnO4 and pH 12.0 phosphate buffer (K2HPO4/NaOH), a detection limit of 1.0 x 10(-8) M (1.5 ppb) and a linear dynamic range of 2.5 x 10(-8) to 2.5 x 10(-7) M can be obtained. A repetitive injection of 1.0 x 10-7 M paracetamol solutions gave satisfactory reproducibility with a relative standard deviation of 2.3% (n = 12). Possible interferences from major excipients in pharmaceuticals and other related compounds were also studied. Contents of paracetamol in two locally available pharmaceuticals were analyzed. From the recovery of 98.2-104.4% obtained, the feasibility of the developed method for real sample analysis was confirmed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 25 条
[1]  
Alapont AG, 1999, J PHARMACEUT BIOMED, V21, P311
[2]  
ALWARTHAN AA, 1986, ANAL CHIM ACTA, V185, P635
[3]   SPECTROFLUORIMETRIC DETERMINATION OF PHARMACEUTICAL COMPOUNDS WITH THE CERIUM(IV)-CERIUM(III) SYSTEM [J].
AMANN, G ;
GUBITZ, G ;
FREI, RW ;
SANTI, W .
ANALYTICA CHIMICA ACTA, 1980, 116 (01) :119-125
[4]  
BOUSHSAIN Z, 1996, ANAL CHIM ACTA, V330, P59
[5]  
BOUSHSAIN Z, 1996, ANALYST, V121, P635
[6]   ACUTE LIVER NECROSIS FOLLOWING OVERDOSE OF PARACETAMOL [J].
DAVIDSON, DG ;
EASTHAM, WN .
BRITISH MEDICAL JOURNAL, 1966, 2 (5512) :497-&
[7]   GLC MICROANALYSES OF PHENACETIN AND ACETAMINOPHEN PLASMA-LEVELS [J].
EVANS, MA ;
HARBISON, RD .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (11) :1628-1629
[8]   APPLICATION OF A VOLTAMETRIC FLOW-THROUGH CELL TO FLOW-INJECTION-ANALYSIS (FIA) [J].
IVASKA, A ;
RYAN, TH .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1981, 46 (11) :2865-2970
[9]   DETERMINATION OF PHENYLPROPANOLAMINE HYDROCHLORIDE AND ACETAMINOPHEN IN PHARMACEUTICAL PREPARATIONS BY RAMAN-SPECTROSCOPY [J].
KING, TH ;
MANN, CK ;
VICKERS, TJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1985, 74 (04) :443-447
[10]   CONTINUOUS-FLOW CHEMI-LUMINESCENCE DETERMINATION OF ACETAMINOPHEN BY REDUCTION OF CERIUM(IV) [J].
KOUKLI, II ;
CALOKERINOS, AC ;
HADJIIOANNOU, TP .
ANALYST, 1989, 114 (06) :711-714