CFD simulation of airborne pathogen transport due to human activities

被引:85
作者
Hathway, E. A. [1 ]
Noakes, C. J. [1 ]
Sleigh, P. A. [1 ]
Fletcher, L. A. [1 ]
机构
[1] Univ Leeds, Pathogen Control Engn Inst, Dept Civil Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
CFD; Bioaerosols; MRSA; Health-care associated infection; STAPHYLOCOCCUS-AUREUS; PARTICLE DEPOSITION; VENTILATION PATTERN; INDOOR AIR; TRANSMISSION; DISPERSION; PERFORMANCE; REDUCTION; INFECTION; EXPOSURE;
D O I
10.1016/j.buildenv.2011.06.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Computational Fluid Dynamics (CFD) is an increasingly popular tool for studying the impact of design interventions on the transport of infectious microorganisms. While much of the focus is on respiratory infections, there is substantial evidence that certain pathogens, such as those which colonise the skin, can be released into, and transported through the air through routine activities. In these situations the bacteria is released over a volume of space, with different intensities and locations varying in time rather than being released at a single point. This paper considers the application of CFD modelling to the evaluation of risk from this type of bioaerosol generation. An experimental validation study provides a direct comparison between CFD simulations and bioaerosol distribution, showing that passive scalar and particle tracking approaches are both appropriate for small particle bioaerosols. The study introduces a zonal source, which aims to represent the time averaged release of bacteria from an activity within a zone around the entire location the release takes place. This approach is shown to perform well when validated numerically though comparison with the time averaged dispersion patterns from a transient source. However, the ability of a point source to represent such dispersion is dependent on airflow regime. The applicability of the model is demonstrated using a simulation of an isolation room representing the release of bacteria from bedmaking. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2500 / 2511
页数:12
相关论文
共 49 条
  • [1] The ventilation of multiple-bed hospital wards: Review and analysis
    Beggs, Clive B.
    Kerr, Kevin G.
    Noakes, Catherine J.
    Hathway, E. Abigail
    Sleigh, P. Andrew
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2008, 36 (04) : 250 - 259
  • [2] *BGI COLL NEB, 2006, OUTP DISTR COLL NEB
  • [3] Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    Bjorn, E
    Nielsen, PV
    [J]. INDOOR AIR, 2002, 12 (03) : 147 - 164
  • [4] Reduction in MRSA environmental contamination with a portable HEPA-filtration unit
    Boswell, TC
    Fox, PC
    [J]. JOURNAL OF HOSPITAL INFECTION, 2006, 63 (01) : 47 - 54
  • [5] The effect of moving heat sources upon the stratification in rooms ventilated by displacement ventilation
    Brohus, H.
    Balling, K. D.
    Jeppesen, D.
    [J]. INDOOR AIR, 2006, 16 (05) : 356 - 372
  • [6] Centers for Disease Control and Prevention, 2005, MMWR, V54
  • [7] Numerical study of the effect of ventilation pattern on coarse, fine, and very fine particulate matter removal in partitioned indoor environment
    Chang, Tsang-Jung
    Kao, Hong-Ming
    Hsieh, Yi-Fang
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2007, 57 (02) : 179 - 189
  • [8] A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach
    Chao, C. Y. H.
    Wan, M. P.
    [J]. INDOOR AIR, 2006, 16 (04) : 296 - 312
  • [9] CFD analysis of the performance of a local exhaust ventilation system in a hospital ward
    Chau, Oliver K. Y.
    Liu, Chun-Ho
    Leung, Michael K. H.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2006, 15 (03) : 257 - 271
  • [10] Performance of ventilation system in a non-standard operating room
    Chow, TT
    Yang, XY
    [J]. BUILDING AND ENVIRONMENT, 2003, 38 (12) : 1401 - 1411