Optimal parameters and location for diffusion tensor imaging in the diagnosis of carpal tunnel syndrome: a meta-analysis

被引:8
作者
Liu, C.
Li, H. W.
Wang, L.
Zhu, L.
Jiang, X. F.
Yang, M. J.
Li, B.
Zhang, C.
Yang, H. F.
Xu, X. X. [1 ]
机构
[1] North Sichuan Med Coll, Affiliated Hosp, Dept Radiol, 63 Wenhua Rd, Nanchong City 637000, Sichuan, Peoples R China
关键词
MEDIAN NERVE; CLINICAL-SIGNIFICANCE; PERIPHERAL-NERVE; TRACTOGRAPHY; ANISOTROPY; HEALTHY; MRI; NEUROGRAPHY; AGE;
D O I
10.1016/j.crad.2018.08.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess the diagnostic value of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of diffusion tensor imaging (DTI) at several anatomical locations in patients with carpal tunnel syndrome (CTS) to explore the optimal parameters and measurement location. MATERIALS AND METHODS: A search was conducted using the PubMed, EBSCO, Ovid, Web of Science, and Cochrane databases to identify articles relevant to this study published before September 2017. Studies were selected and included according to strict eligibility criteria. Mean differences (MD) and 95% confidence intervals (CIs) were used to compare FA and ADC values between CTS patients and healthy subjects. Potential publication bias was investigated. RESULTS: Eleven studies involving 349 CTS wrists and 278 controls were selected for the meta-analysis. A notable MD: was found for lowered FA at the level of the pisiform bone for CTS versus controls (MD: -0.11, 95% confidence interval [CI]: -1.14 to -0.07, z=5.83, p<0.001). A higher ADC was found at the pisiform bone and hamate bone levels for CTS versus controls (P: MD: 0.15, 95% CI: 0.10 to 0.20, z=5.98, p<0.001, H: MD: 0.15; 95% CI: 0.09 to 0.21, z=4.67, p<0.001). CONCLUSIONS: The meta-analysis demonstrated a significant FA reduction and ADC increase in CTS patients. This result supports the use of DTI parameters in differentiating CTS patients from health subjects. The anatomical site for FA at the pisiform and ADC at the pisiform and hamate levels were more accessible than other sites for the diagnosis of CTS patients. (C) 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1058.e11 / 1058.e19
页数:9
相关论文
共 38 条
[11]   Assessment of Median Nerve with MR Neurography by Using Diffusion-Tensor Imaging: Normative and Pathologic Diffusion Values [J].
Guggenberger, Roman ;
Markovic, Daniel ;
Eppenberger, Patrick ;
Chhabra, Avneesh ;
Schiller, Andreas ;
Nanz, Daniel ;
Pruessmann, Klaas ;
Andreisek, Gustav .
RADIOLOGY, 2012, 265 (01) :194-203
[12]   Evidence-Based Medicine: Current Evidence in the Diagnosis and Management of Carpal Tunnel Syndrome [J].
Hermiz, Steven J. ;
Kalliainen, Loree K. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 140 (01) :120E-129E
[13]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560
[14]   Pre- and post-operative diffusion tensor imaging of the median nerve in carpal tunnel syndrome [J].
Hiltunen, Jaana ;
Kirveskari, Erika ;
Numminen, Jussi ;
Lindfors, Nina ;
Goransson, Harry ;
Hari, Riitta .
EUROPEAN RADIOLOGY, 2012, 22 (06) :1310-1319
[15]   Diagnosis of carpal tunnel syndrome - Electrodiagnostic and magnetic resonance imaging evaluation [J].
Jarvik, JG ;
Yuen, E .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2001, 12 (02) :241-+
[16]   Diffusion tensor imaging and tractography of median nerve:: A normative diffusion values [J].
Kabakci, Neslihan ;
Guerses, Bengi ;
Firat, Zeynep ;
Bayram, Ali ;
Ulug, Aziz Muefit ;
Kovanlikaya, Arzu ;
Kovanlikaya, Ilami .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) :923-927
[17]   Diffusion tensor imaging and tractography of the median nerve in carpal tunnel syndrome: preliminary results [J].
Khalil, C. ;
Hancart, C. ;
Le Thuc, V. ;
Chantelot, C. ;
Chechin, D. ;
Cotten, A. .
EUROPEAN RADIOLOGY, 2008, 18 (10) :2283-2291
[18]   A comparison of the performance of anatomical MRI and DTI in diagnosing carpal tunnel syndrome [J].
Koh, Sung Hye ;
Kwon, Bong Cheol ;
Park, Chanyeong ;
Hwang, Su Yeon ;
Lee, Joon Woo ;
Kim, Sam Soo .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (11) :2065-2073
[19]   Optimal Parameters and Location for Diffusion-Tensor Imaging in the Diagnosis of Carpal Tunnel Syndrome: A Prospective Matched Case-Control Study [J].
Kwon, Bong Cheol ;
Koh, Sung Hye ;
Hwang, Su Yeon .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) :1248-1254
[20]  
Liberati A, 2009, BMJ-BRIT MED J, V339, DOI [10.1371/journal.pmed.1000097, 10.1136/bmj.b2700, 10.1186/2046-4053-4-1, 10.1136/bmj.i4086, 10.1136/bmj.b2535, 10.1016/j.ijsu.2010.02.007, 10.1016/j.ijsu.2010.07.299]