Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions

被引:36
作者
Bonaccorso, Antonio [1 ]
Tripi, Teresa Roberta [2 ]
Rondelli, Gianni [4 ]
Condorelli, Guglielmo Guido [3 ]
Cantatore, Giuseppe [5 ]
Schaefer, Edgar [6 ]
机构
[1] Private Practice, Catania, Italy
[2] Univ Catania, Fac Dent, Catania, Italy
[3] Univ Catania, Dept Chem Sci, Catania, Italy
[4] Univ Milan, INR Dept, Milan, Italy
[5] Univ Verona, Fac Dent, I-37100 Verona, Italy
[6] Univ Munster, Dept Operat Dent, Munster, Germany
关键词
endodontic files; irrigating solutions; localized corrosion; Ni-Ti alloy; surface treatments;
D O I
10.1016/j.joen.2007.11.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the pitting corrosion resistance of nickel-titanium (NiTi) rotary instruments with different surface treatments in 17% ethylenediaminetetraacetic acid (EDTA) and NaCl solutions. Electropolished RaCe instruments were allocated to group A, non-electropolished RaCe instruments to group B, and physical vapor deposition (PVD)-coated Alpha files to group C (10 instruments per group). Electrochemical measurements were carried out by using a potentiostat for galvanic current measurements. On the basis of electrochemical tests, no localized corrosion problems are to be expected in EDTA. In NaCl, pitting potential occurred at higher values for the electropolished and PVD instruments, indicating an increased corrosion resistance. There appears to be a risk of corrosion for NiTi instruments without surface treatments in contact with NaCl. NiTi files with PVD and electropolishing surface treatments showed an increase corrosion resistance.
引用
收藏
页码:208 / 211
页数:4
相关论文
共 34 条
  • [1] *ASTM, 1999, 03 02 WEAR ER MET CO, P237
  • [2] *ASTM, 1999, 03 02 WEAR ER MET CO, P54
  • [3] CALLISTER WD, 2000, MAT SCI ENG INTRO, P223
  • [4] Time-dependent effects of EDTA on dentin structures
    Çalt, S
    Serper, A
    [J]. JOURNAL OF ENDODONTICS, 2002, 28 (01) : 17 - 19
  • [5] Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions
    Darabara, M
    Bourithis, L
    Zinelis, S
    Papadimitriou, GD
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (10) : 705 - 710
  • [6] Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopy
    Eggert, C
    Peters, O
    Barbakow, F
    [J]. JOURNAL OF ENDODONTICS, 1999, 25 (07) : 494 - 497
  • [7] Cyclic fatigue of Profile rotary instruments after prolonged clinical use
    Gambarini, G
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) : 386 - 389
  • [8] KOVACS P, 1992, P CORR NACE ANN C
  • [9] Tribological and electrochemical performance of PVD TiN coatings on the femoral head of Ti-6Al-4V artificial hip joints
    Liu, C
    Bi, Q
    Matthews, A
    [J]. SURFACE & COATINGS TECHNOLOGY, 2003, 163 : 597 - 604
  • [10] EFFECT OF STERILIZATION AND IRRIGANTS ON THE CUTTING ABILITY OF STAINLESS-STEEL FILES
    NEAL, RG
    CRAIG, RG
    POWERS, JM
    [J]. JOURNAL OF ENDODONTICS, 1983, 9 (03) : 93 - 96