A realistic, accurate and fast source modeling approach for the EEG forward problem

被引:32
|
作者
Miinalainen, Tuuli [1 ,3 ,4 ,5 ]
Rezaei, Atena [1 ]
Us, Defne [1 ,2 ]
Nuessing, Andreas [3 ,4 ]
Engwer, Christian [4 ]
Wolters, Carsten H. [3 ]
Pursiainen, Sampsa [1 ]
机构
[1] Tampere Univ Technol, Lab Math, POB 692, FIN-33101 Tampere, Finland
[2] Tampere Univ Technol, Lab Signal Proc, POB 553, FIN-33101 Tampere, Finland
[3] Univ Munster, Inst Biomagnetism & Biosignalanal, Malmedyweg 15, D-48149 Munster, Germany
[4] Univ Munster, Inst Computat & Appl Math, Einsteinstr 62, D-48149 Munster, Germany
[5] Univ Eastern Finland, Dept Appl Phys, POB 1627, FI-70211 Kuopio, Finland
基金
芬兰科学院;
关键词
Electroencephalography (EEG); Finite element method (FEM); Divergence conforming vector fields; Focal sources; DUNE toolbox; FINITE-ELEMENT-METHOD; INVERSE PROBLEM; HEAD MODELS; BRAIN; SKULL; ELECTROENCEPHALOGRAPHY; LOCALIZATION; ANISOTROPY; FIELD; VISUALIZATION;
D O I
10.1016/j.neuroimage.2018.08.054
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this paper is to advance electroencephalography (EEG) source analysis using finite element method (FEM) head volume conductor models that go beyond the standard three compartment (skin, skull, brain) approach and take brain tissue inhomogeneity (gray and white matter and cerebrospinal fluid) into account. The new approach should enable accurate EEG forward modeling in the thin human cortical structures and, more specifically, in the especially thin cortices in children brain research or in pathological applications. The source model should thus be focal enough to be usable in the thin cortices, but should on the other side be more realistic than the current standard mathematical point dipole. Furthermore, it should be numerically accurate and computationally fast. We propose to achieve the best balance between these demands with a current preserving (divergence conforming) dipolar source model. We develop and investigate a varying number of current preserving source basis elements n (n = 1, ..., n=5). For validation, we conducted numerical experiments within a multi-layered spherical domain, where an analytical solution exists. We show that the accuracy increases along with the number of basis elements, while focality decreases. The results suggest that the best balance between accuracy and focality in thin cortices is achieved with n = 4 (or in extreme cases even n = 3) basis functions, while in thicker cortices n = 5 is recommended to obtain the highest accuracy. We also compare the current preserving approach to two further FEM source modeling techniques, namely partial integration and St. Venant, and show that the best current preserving source model outperforms the competing methods with regard to overall balance. For all tested approaches, FEM transfer matrices enable high computational speed. We implemented the new EEG forward modeling approaches into the open source duneuro library for forward modeling in bioelectromagnetism to enable its broader use by the brain research community. This library is build upon the DUNE framework for parallel finite elements simulations and integrates with high-level toolboxes like FieldTrip. Additionally, an inversion test has been implemented using the realistic head model to demonstrate and compare the differences between the aforementioned source models.
引用
收藏
页码:56 / 67
页数:12
相关论文
共 50 条
  • [41] HIERARCHICAL BAYESIAN MODEL FOR SIMULTANEOUS EEG SOURCE AND FORWARD MODEL RECONSTRUCTION (SOFOMORE)
    Stahlhut, Carsten
    Morup, Morten
    Winther, Ole
    Hansen, Lars Kai
    2009 IEEE INTERNATIONAL WORKSHOP ON MACHINE LEARNING FOR SIGNAL PROCESSING, 2009, : 452 - 457
  • [42] SOFOMORE: COMBINED EEG SOURCE AND FORWARD MODEL RECONSTRUCTION
    Stahlhut, Carsten
    Morup, Morten
    Winther, Ole
    Hansen, Lars Kai
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 450 - 453
  • [43] Flexible-Center Hat Complete Electrode Model for EEG Forward Problem
    Zhang, Ting
    Liu, Yan
    Ma, Erfang
    Peng, Bo
    Aarabi, Ardalan
    Zhang, Siqi
    Hu, Ying
    Xiang, Jing
    Dai, Yakang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (08) : 2287 - 2299
  • [44] Using reciprocity for relating the simulation of transcranial current stimulation to the EEG forward problem
    Wagner, S.
    Lucka, F.
    Vorwerk, J.
    Herrmann, C. S.
    Nolte, G.
    Burger, M.
    Wolters, C. H.
    NEUROIMAGE, 2016, 140 : 163 - 173
  • [45] Computational aspects of finite element modeling in EEG source localization
    Awada, KA
    Jackson, DR
    Williams, JT
    Wilton, DR
    Baumann, SB
    Papanicolaou, AC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (08) : 736 - 752
  • [46] The effect of stimulation type, head modeling, and combined EEG and MEG on the source reconstruction of the somatosensory P20/N20 component
    Antonakakis, Marios
    Schrader, Sophie
    Wollbrink, Ndreas
    Oostenveld, Robert
    Rampp, Stefan
    Haueisen, Jens
    Wolters, Carsten H.
    HUMAN BRAIN MAPPING, 2019, 40 (17) : 5011 - 5028
  • [47] Diagnosis of Early Alzheimer's Disease Based on EEG Source Localization and a Standardized Realistic Head Model
    Aghajani, Haleh
    Zahedi, Edmond
    Jalili, Mahdi
    Keikhosravi, Adib
    Vahdat, Bijan Vosoughi
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2013, 17 (06) : 1039 - 1045
  • [48] Dipole estimation errors due to not incorporating anisotropic conductivities in realistic head models for EEG source analysis
    Hallez, Hans
    Staelens, Steven
    Lemahieu, Ignace
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20): : 6079 - 6093
  • [49] A Mixed Finite Element Method to Solve the EEG Forward Problem
    Vorwerk, J.
    Engwer, C.
    Pursiainen, S.
    Wolters, C. H.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (04) : 930 - 941
  • [50] A finite difference method to solve the forward problem in electroencephalography (EEG)
    Hédou-Rouillier, V
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2004, 167 (01) : 35 - 58