Non-specific adsorption of protein to microfluidic materials

被引:11
|
作者
Rashid, Sabaa [1 ,4 ]
Ward-Bond, Jesse [1 ,4 ]
Krupin, Oleksiy [2 ,4 ]
Berini, Pierre [2 ,3 ,4 ]
机构
[1] Univ Ottawa, Dept Chem & Biol Engn, Ottawa, ON, Canada
[2] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON, Canada
[3] Univ Ottawa, Dept Phys, Ottawa, ON, Canada
[4] Univ Ottawa, Ctr Res Photon, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Non-specific adsorption; Biofouling; Biosensing; Surface characterization; CYTOP; BOVINE SERUM-ALBUMIN; PLASMON WAVE-GUIDES; SURFACE;
D O I
10.1016/j.colsurfb.2021.112138
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Non-specific adsorption of proteins to the surfaces of microfluidic channels poses a serious problem in lab-on-achip devices involving complex biological fluids. Materials commonly used in the formation of microfluidic channels include CYTOP, silica and SU-8. CYTOP is a transparent fluoropolymer (Poly[perfluoro(4-vinyloxy-1butene)]) with a low refractive index that approximately matches the refractive index of biologically compatible fluids, and is useful in optical biosensors. Using a microfluidic and fluorescence microscopy set-up, the nonspecific adsorption of bovine serum albumin (BSA) labeled with fluorescein isothiocyanate (FITC) to three grades of CYTOP (S, M and A), silica, and SU-8 is investigated. Surface properties such as roughness and wettability are also characterized via an atomic force microscope and a contact angle measurement system. The non-specific adsorption of protein occurs with a highly variable load across these materials. Surprisingly, significantly lower adsorption occurred on SU-8 compared to the other materials, likely due to its hydrophilicity (post-cleaning). Among the 3 grades of CYTOP considered, the lowest adsorption occurred on S-grade. BSA adsorption to silica was higher than on S-grade CYTOP and significantly higher than on SU-8 despite being hydrophilic, due to a fixed positive charge formed within the layer during fabrication, which attracts negativelycharged BSA in buffer.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Methods of reducing non-specific adsorption in microfluidic biosensors
    Choi, Seokheun
    Chae, Junseok
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (07)
  • [2] Non-specific protein-membrane interactions: Adsorption and fouling
    Zydney, AL
    BIOFUNCTIONAL MEMBRANES, 1996, : 279 - 288
  • [3] Assembling Surface Linker Chemistry with Minimization of Non-Specific Adsorption on Biosensor Materials
    Sheng, Jack Chih-Chieh
    De La Franier, Brian
    Thompson, Michael
    MATERIALS, 2021, 14 (02) : 1 - 15
  • [4] Non-specific protein therapy
    不详
    BRITISH MEDICAL JOURNAL, 1932, 1932 (02): : 597 - 598
  • [5] A dissection of specific and non-specific protein - Protein interfaces
    Bahadur, RP
    Chakrabarti, P
    Rodier, F
    Janin, J
    JOURNAL OF MOLECULAR BIOLOGY, 2004, 336 (04) : 943 - 955
  • [6] Inhibition of non-specific protein adsorption on PMMA surface: The role of surface modification
    Xian, Zhaokun
    Dai, Peng
    Su, Wenyun
    Xing, Dong
    Sun, Cuimin
    You, Hui
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2023, 27 (06)
  • [7] Non-specific adhesion on biomaterial surfaces driven by small amounts of protein adsorption
    Kalasin, Surachate
    Santore, Maria M.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 73 (02) : 229 - 236
  • [8] Specific and non-specific contacts in protein crystals
    Dan, F
    Zeng, ZH
    PROTEIN AND PEPTIDE LETTERS, 2004, 11 (04): : 361 - 366
  • [9] Biofunctional polyelectrolyte multilayers and microcapsules:: Control of non-specific and bio-specific protein adsorption
    Heuberger, R
    Sukhorukov, G
    Vörös, J
    Textor, M
    Möhwald, H
    ADVANCED FUNCTIONAL MATERIALS, 2005, 15 (03) : 357 - 366
  • [10] Non-Specific Adsorption Reduction Methods in Biosensing
    Lichtenberg, Jessanne Y.
    Ling, Yue
    Kim, Seunghyun
    SENSORS, 2019, 19 (11)