An exergy-based minimum carbon footprint model for optimum equipment oversizing and temperature peaking in low-temperature district heating systems

被引:24
作者
Kilkis, Birol [1 ,2 ]
机构
[1] OSTIM Tech Univ, Ankara, Turkey
[2] Polar Design & Technol, Ankara, Turkey
关键词
Low-exergy; Low-temperature district heating; Equipment oversizing; Heat pump cascading; Temperature peaking; PVT system; Hydrogen house; Wind-to-heat; Hydrogen economy; ENERGY; CITIES; POWER;
D O I
10.1016/j.energy.2021.121339
中图分类号
O414.1 [热力学];
学科分类号
摘要
Total decarbonization strategies are facing technical and environmental challenges according to the 2nd Law of Thermodynamics, such as equipment oversizing versus temperature peaking by heat pumps to accommodate low-temperature renewable and waste energy sources. As a method of this paper, the Rational Exergy Management Model (REMM) derived fourteen metrics, aiming to minimize the CO2 emissions responsibility. Two case studies are presented. One of them is a fifth-generation district energy system concept with a 250 MW design heating load of 20,000 residence-equivalent apartments at a supply temperature of 35 degrees C. Results showed that two heat pumps in a cascade achieved a 23% higher exergy utilization rate with an optimum temperature peaking to 45 degrees C and 25% radiator oversizing. The second case study is concerned with the strategy of the Chinese government to substitute the domestic use of coal and wood with local wind turbines for electric heating to combat global warming. Five alternatives were considered; 1-Wind electricity to resistance heating, 2-Wind electricity to heat pumps, 3-Wind electricity to mini hydrogen fuel cells, 4-Wind electricity to hydrogen and micro-cogeneration, and 5-Hydrogen district systems with biogas, geothermal, and solar energy. Results showed that Case 1 has the maximum carbon footprint, whereas a custom-designed hydrogen house has the least footprint leading to about 90% CO2 emissions responsibility emanating from exergy destructions. The paper concludes that low-temperature heating either in district energy systems, in private buildings, or prosumers is both environmentally, economically, and technically feasible. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:20
相关论文
共 56 条
[1]  
Al-Mosavi AI., 2016, FLAMMABILITY COMPOSI, P361, DOI [10.1016/B978-1-78242-325-6.00014-1, DOI 10.1016/B978-1-78242-325-6.00014-1]
[2]   Exergoeconomic analysis of a district heating system for geothermal energy using specific exergy cost method [J].
Alkan, Mehmet Ali ;
Kecebas, Ali ;
Yamankaradeniz, Nurettin .
ENERGY, 2013, 60 :426-434
[3]  
Anke Esser A, 2016, FINAL REPORT EVALUAT
[4]  
[Anonymous], 2016, Global Waste Management Outlook, DOI DOI 10.18356/765BAEC0-EN
[5]  
[Anonymous], 2018, Capitalism and EnvironmentalCollapse, P1, DOI [10.1109/IEEESTD.2018.8457469, DOI 10.1109/IEEESTD.2018.8457469]
[6]  
[Anonymous], 2017, 55 ANSIASHRAE
[7]  
BEIS, 2018, 21 BEIS
[8]   Bidirectional low temperature district energy systems with agent-based control: Performance comparison and operation optimization [J].
Buenning, Felix ;
Wetter, Michael ;
Fuchs, Marcus ;
Mueller, Dirk .
APPLIED ENERGY, 2018, 209 :502-515
[9]  
Chang R, 2019, ASHRAE J, V61, P12
[10]  
Chiasson AD, 2016, GEOTHERMAL HEAT PUMP