Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation With the Medtronic CoreValve System in Patients With Aortic Stenosis

被引:54
作者
Tzikas, Apostolos [1 ]
Piazza, Nicolo [1 ]
Geleijnse, Marcel L. [1 ]
Van Mieghem, Nicolas [1 ]
Nuis, Rutger-Jan [1 ]
Schultz, Carl [1 ]
van Geuns, Robert-Jan [1 ]
Galema, Tjebbe W. [1 ]
Kappetein, Arie-Pieter [1 ]
Serruys, Patrick W. [1 ]
de Jaegere, Peter P. [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, Rotterdam, Netherlands
关键词
LONG-TERM SURVIVAL; IMPACT; REPLACEMENT;
D O I
10.1016/j.amjcard.2010.02.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A prosthesis patient mismatch (PPM) is present when the prosthetic valve is too small in relation to the patient's body size. The purpose of the present study was to investigate the frequency of PPM after the implantation of the Medtronic Core Valve System, and its relation to the clinical outcome. The indexed effective orifice area (EOA) was measured in 74 patients with symptomatic severe aortic stenosis, who had undergone successful transcatheter aortic valve implantation with the Medtronic Core Valve System, at baseline and discharge. PPM was defined as severe (indexed EOA <0.65 cm(2)/m(2)) or moderate (indexed EOA 0.65 to 0.85 cm(2)/m(2)). The indexed EOA increased from 0.35 +/- 0.13 to 0.97 +/- 0.34 cm(2)/m(2) after transcatheter aortic valve implantation (p <0.001) and was accompanied by significant clinical improvement. Severe and moderate PPMs were found in 16% and 23% of patients, respectively. Patients with severe PPM were more symptomatic and had a smaller indexed EOA at baseline than those with moderate or no PPM (0.28 +/- 0.09 vs 0.36 +/- 0.12 cm(2)/m(2), p <0.05). Functional status and mortality at 30 days and 6 months was not significantly different between the patients with severe PPM and those with moderate or no PPM. In conclusion, the indexed EOA increased significantly after transcatheter aortic valve implantation. Severe PPM was observed in 16% of the patients and was not associated with the clinical outcome. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:255-260)
引用
收藏
页码:255 / 260
页数:6
相关论文
共 15 条
[1]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[2]   Impact of valve prosthesis-patient mismatch estimated by echocardiographic-determined effective orifice area on long-term outcome after aortic valve replacement [J].
Florath, Ines ;
Albert, Alexander ;
Rosendahl, Utrich ;
Ennker, Ina Carolin ;
Ennker, Juergen .
AMERICAN HEART JOURNAL, 2008, 155 (06) :1135-1142
[3]   Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study [J].
Grube, Eberhard ;
Laborde, Jean C. ;
Gerckens, Ulrich ;
Felderhoff, Thomas ;
Sauren, Barthel ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Menichelli, Maurizio ;
Schmidt, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Stone, Gregg W. .
CIRCULATION, 2006, 114 (15) :1616-1624
[4]  
JILAIHAWI H, EUR HEART J
[5]   Impact of Prosthesis-Patient Mismatch on Long-Term Survival After Aortic Valve Replacement Influence of Age, Obesity, and Left Ventricular Dysfunction [J].
Mohty, Dania ;
Dumesnil, Jean G. ;
Echahidi, Najmeddine ;
Mathieu, Patrick ;
Dagenais, Francois ;
Voisine, Pierre ;
Pibarot, Philippe .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (01) :39-47
[6]   Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude medical mechanical prostheses in the aortic position [J].
Mohty-Echahidi, D ;
Malouf, JF ;
Girard, SE ;
Schaff, HV ;
Grill, DE ;
Enriquez-Sarano, ME ;
Miller, FA .
CIRCULATION, 2006, 113 (03) :420-426
[7]   Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival [J].
Monin, Jean-Luc ;
Monchi, Mehran ;
Kirsch, Matthias E. W. ;
Petit-Eisenmann, Helene ;
Baleynaud, Serge ;
Chauvel, Christophe ;
Metz, Damien ;
Adams, Catherine ;
Quere, Jean-Paul ;
Gueret, Pascal ;
Tribouilloy, Christophe .
EUROPEAN HEART JOURNAL, 2007, 28 (21) :2620-2626
[8]   Prosthesis-patient mismatch: myth or reality? [J].
Monin, Jean-Luc .
HEART, 2009, 95 (11) :948-952
[9]   POINT: Prosthesis - patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthetic aortic valve replacement [J].
Moon, Marc R. ;
Lawton, Jennifer S. ;
Moazami, Nader ;
Munfakh, Nabil A. ;
Pasque, Michael K. ;
Damiano, Ralph J., Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (02) :278-283
[10]  
Piazza Nicolo, 2008, EuroIntervention, V4, P242, DOI 10.4244/EIJV4I2A43