Dynamic computed tomography of the neonatal lung -: Volume calculations and validation in an animal model

被引:10
作者
Elgeti, T
Proquitté, H
Rogalla, NE
Mews, J
Wauer, R
Hamm, B
Schmalisch, G
Rogalla, P
机构
[1] Univ Med Berlin, Dept Radiol, Berlin, Germany
[2] Univ Med Berlin, Neurol Clin, Berlin, Germany
[3] Toshiba Med Syst, Otawara, Japan
关键词
chest CT; neonatal animal; volumetry; segmentation; piglet;
D O I
10.1097/01.rli.0000185879.60005.b9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this Study was to evaluate and validate dynamic volume calculation by respiratory-gated multislice computed tomography (CT) in small neonatal animals. Materials and Methods: Six mechanically ventilated newborn piglets were imaged in a multislice CT with 0.5-mm slice thickness (4:16 pitch, 0.5-second rotation time, 120 kV). The respirator was connected to the CT unit for recording the respiratory signal. Simultaneously, tidal volume was measured by the respirator and functional residual capacity (FRC) using a multiple-breath washin-washout technique (MBW) with heptafluoropropane (HFP) as tracer gas. Complete volume datasets were reconstructed throughout the respiratory cycle in increments of 10% using retrospective half-scan gating. All animals were scanned in 3 different ventilator settings. Dynamic lung volumes (tidal Volumes) were calculated by means of segmentation of the lung parenchyma during the respiratory cycle using work-in-progress software. Results: The mean (+/- standard deviation) FRC determined by CT was 24.7 +/- 8.6 mL versus 24.8 +/- 7.3 mL for the MBW technique. There was no statistically significant difference (P = 0.555). Pearson's correlation coefficient showed a strong correlation between the data obtained with CT and that obtained with the MBW technique (r = 0.886). After exclusion of one outlier, tidal volumes showed a similar correlation (r = 0.837) without significant differences in the mean values (CT: 8.9 +/- 2.4 mL and respirator: 8.7 +/- 2.4 ml, P = 0.566). Conclusion: Dynamic multislice CT with respiratory gating allows for calculation of lung volumes and may be useful for future CT applications in human neonatal lung imaging.
引用
收藏
页码:761 / 765
页数:5
相关论文
共 32 条
  • [1] Computer aided diagnosis in chest radiology - Current topics and techniques
    Achenbach, T
    Vomweg, T
    Heussel, CP
    Thelen, M
    Kauczor, HU
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (11): : 1471 - 1481
  • [2] Quantification of atelectases in artificial respiration: Spiral-CT versus dynamic single-slice CT
    Bletz, C
    Markstaller, K
    Karmrodt, J
    Herweling, A
    Melvan, M
    Goetz, R
    Stepniak, A
    Eberle, B
    Kauczor, HU
    Heussel, CP
    Thelen, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (03): : 409 - 416
  • [3] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [4] Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study
    Brix, G
    Lechel, U
    Veit, R
    Truckenbrodt, R
    Stamm, G
    Coppenrath, EM
    Griebel, J
    Nagel, HD
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (07) : 1275 - 1284
  • [5] Coulier B, 1999, JBR-BTR, V82, P6
  • [6] Feasibility of pulmonary ventilation visualization with aerosolized magnetic resonance contrast media
    Haage, P
    Karaagac, S
    Spüntrup, E
    Truong, HT
    Schmidt, T
    Günther, RW
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (02) : 85 - 88
  • [7] Electrocardiographically gated 16-section CT of the thorax: Cardiac motion suppression
    Hofmann, LK
    Zou, KH
    Costello, P
    Schoepf, UJ
    [J]. RADIOLOGY, 2004, 233 (03) : 927 - 933
  • [8] Multislice spiral CT (MSCT) in pediatric radiology:: Dose reduction for chest and abdomen examinations
    Honnef, D
    Wildberger, JE
    Stargardt, A
    Hohl, C
    Barker, M
    Günther, RW
    Staatz, G
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (07): : 1021 - 1030
  • [9] Air trapping in children: Evaluation with dynamic lung densitometry with spiral CT
    Johnson, JL
    Kramer, SS
    Mahboubi, S
    [J]. RADIOLOGY, 1998, 206 (01) : 95 - 101
  • [10] CT attenuation of paired HRCT scans obtained at full inspiratory/expiratory position: comparison with pulmonary function tests
    Kauczor, HU
    Hast, J
    Heussel, CP
    Schlegel, J
    Mildenberger, P
    Thelen, M
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2757 - 2763