A Study on a Control Method with a Ventilation Requirement of a VAV System in Multi-Zone

被引:14
作者
Kim, Hyo-Jun [1 ]
Cho, Young-Hum [2 ]
机构
[1] Yeungnam Univ, Grad Sch, Dept Architectural Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
[2] Yeungnam Univ, Sch Architecture, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
关键词
VAV system; terminal unit; TRNSYS; control method; multi-zone; ventilation requirement; MINIMUM AIR-FLOW; DEMAND-CONTROLLED VENTILATION; CONDITIONING SYSTEMS; TEMPERATURE; DAMPERS;
D O I
10.3390/su9112066
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to propose a control method with a ventilation requirement of variable air volume (VAV) system in multi-zone. In order to control the VAV system inmulti-zone, it is essential to control the terminal unit installed in each zone. A VAV terminal unit with conventional control method using a fixed minimum air flow can cause indoor air quality (IAQ) issues depending on the variation in the number of occupants. This research proposes a control method with a ventilation requirement of the VAV terminal unit and AHU inmulti-zone. The integrated control method with an air flow increase model in the VAV terminal unit, AHU, and outdoor air intake rate increase model in the AHU was based on the indoor CO2 concentration. The conventional and proposed control algorithms were compared through a TRNSYS simulation program. The proposed VAV terminal unit control method satisfies all the conditions of indoor temperature, IAQ, and stratification. An energy comparison with the conventional control method showed that the method satisfies not only the indoor thermal comfort, IAQ, and stratification issue, but also reduces the energy consumption.
引用
收藏
页数:17
相关论文
共 25 条
  • [1] American Society of Heating, 2010, 552010 ASHRAE
  • [2] American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE), 2004, DES APPL CONTR ASH
  • [3] American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE), 2010, 6212010 ASHRAE
  • [4] American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE), 2010, 9012010 ASHRAE
  • [5] [Anonymous], 2010, MULT ZON BUILD WITH, V5
  • [6] Development of a Terminal Control System with Variable Minimum Airflow Rate
    Cho, Young-Hum
    [J]. ENERGIES, 2012, 5 (11) : 4643 - 4664
  • [7] Correlation between minimum airflow and discharge air temperature
    Cho, Young-Hum
    Liu, Mingsheng
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (07) : 1601 - 1611
  • [8] Minimum airflow reset of single duct VAV terminal boxes
    Cho, Young-Hum
    Liu, Mingsheng
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (09) : 1876 - 1885
  • [9] Single-duct constant volume system optimization
    Cho, Young-Hum
    Liu, Mingsheng
    [J]. ENERGY AND BUILDINGS, 2009, 41 (08) : 856 - 862
  • [10] HVAC system optimization with CO2 concentration control using genetic algorithms
    Congradac, Velimir
    Kulic, Filip
    [J]. ENERGY AND BUILDINGS, 2009, 41 (05) : 571 - 577