Observer agreement of spine stenosis on magnetic resonance imaging analysis of patients with cervical spine myelopathy

被引:16
作者
Cook, Chad [1 ,2 ]
Braga-Baiak, Andresa [3 ]
Pietrobon, Ricardo [4 ]
Shah, Anand
Neto, Arnolfo Carvalho [5 ]
de Barros, Nestor [3 ]
机构
[1] Duke Univ, Med Ctr, Ctr Excellence Surg Outcomes, Durham, NC 27710 USA
[2] Duke Univ, Div Phys Therapy, Durham, NC 27710 USA
[3] Univ Sao Paulo, Dept Radiol, Postgrad Program, Sao Paulo, Brazil
[4] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[5] Univ Fed Parana, Dept Radiol, BR-80060000 Curitiba, Parana, Brazil
关键词
reproducibility of results; magnetic resonance imaging; myelopathy; cervical vertebrae;
D O I
10.1016/j.jmpt.2008.03.006
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 36 条
[1]  
BATZDORF U, 1991, SPINE, V16, P123, DOI 10.1097/00007632-199116020-00004
[2]  
Boutin R D, 2000, Magn Reson Imaging Clin N Am, V8, P471
[3]  
Boyce Robert H, 2003, Instr Course Lect, V52, P489
[4]   Cervical degenerative disease at flexion-extension MR imaging: Prediction criteria [J].
Chen, CJ ;
Hsu, HL ;
Niu, CC ;
Chen, TY ;
Chen, MC ;
Tseng, YC ;
Wong, YC ;
Wang, LJ .
RADIOLOGY, 2003, 227 (01) :136-142
[5]   HIGH AGREEMENT BUT LOW KAPPA .2. RESOLVING THE PARADOXES [J].
CICCHETTI, DV ;
FEINSTEIN, AR .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1990, 43 (06) :551-558
[6]   The clinical presentation and impact of diagnostic delays on emergency department patients with spinal epidural abscess [J].
Davis, DP ;
Wold, RM ;
Patel, RJ ;
Tran, AJ ;
Tokhi, RN ;
Chan, TC ;
Vilke, GM .
JOURNAL OF EMERGENCY MEDICINE, 2004, 26 (03) :285-291
[7]   THE DEVELOPMENTAL SEGMENTAL SAGITTAL DIAMETER OF THE CERVICAL SPINAL-CANAL IN PATIENTS WITH CERVICAL SPONDYLOSIS [J].
EDWARDS, WC ;
LAROCCA, H .
SPINE, 1983, 8 (01) :20-27
[8]  
Emery S E, 2001, J Am Acad Orthop Surg, V9, P376
[9]   Interobserver and intraobserver reliability of maximum canal compromise and spinal cord compression for evaluation of acute traumatic cervical spinal cord injury [J].
Fehlings, Michael G. ;
Furlan, Julio C. ;
Massicotte, Eric M. ;
Arnold, Paul ;
Aarabi, Bizhan ;
Harrop, James ;
Anderson, D. Greg ;
Bono, Christopher M. ;
Dvorak, Marcel ;
Fisher, Charles ;
France, John ;
Hedlund, Rune ;
Madrazo, Ignacio ;
Nockels, Russ ;
Rampersaud, Raja ;
Rechtine, Glenn ;
Vaccaro, Alexander R. .
SPINE, 2006, 31 (15) :1719-1725
[10]   THE PROGNOSIS OF SURGERY FOR CERVICAL COMPRESSION MYELOPATHY - AN ANALYSIS OF THE FACTORS INVOLVED [J].
FUJIWARA, K ;
YONENOBU, K ;
EBARA, S ;
YAMASHITA, K ;
ONO, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (03) :393-398