Study of Photoacoustic Imaging based on all-optical Detection

被引:0
作者
Lin, Zhenheng [1 ]
Lin, Chun [1 ]
Lu, Xizhao [1 ]
Ye, Ruifang [1 ]
Huang, Yuanqing [1 ]
机构
[1] Xiamen Univ, Sch Phys & Mech & Elect Engn, Xiamen 361005, Peoples R China
来源
2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS | 2009年 / 7160卷
关键词
all-optical detection; photoacoustic imaging; ESPI; imaging reconstruction; BIOLOGICAL TISSUES; TOMOGRAPHY; INTERFEROMETRY; RECONSTRUCTION; DISPLACEMENT; ALGORITHM;
D O I
10.1117/12.807018
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photoacoustic imaging is attracting increasing interests in biomedical imaging. The comparing between the traditional piezoelectric detections and optical detections is described. Three kinds of all-optical detection photoacoustic imaging systems, including system based on optical reflectance at a glass-liquid interface, system based on FP polymer film and the system based on POISe, are introduced and compared in this paper. Because these methods are difficult to realize measuring the photoacoustic signal on a 2D plane with the backward detection mode, a new kind of photoacoustic imaging system based on Electronic Speckle Pattern Interferometry (ESPI) is proposed. An ESPI outside displacement measurement system is adopted to detect the surface displacement of sample. Since the exposure time of a standard CCD which is of the order of tens of milliseconds, the temporal resolution to sample an acoustic field at MHz frequencies is achieved by interrogating the sensor with a short laser pulse whose bandwidth is about 20ns. After measuring and disposing the displacement data of the sample at a series detecting time, the photoacoustic image will be reconstructed by a delay and sum beam-forming algorithm or by a reconstruction algorithm based on the decomposition. In principle, the system will realize noncontact and backward-mode inspection and smaller element sizes of the receiver in the photoacoustic imaging application.
引用
收藏
页数:8
相关论文
共 22 条
[1]   Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer [J].
Beard, PC ;
Mills, TN .
APPLIED OPTICS, 1996, 35 (04) :663-675
[2]   2D line-scan photoacoustic imaging of absorbers in a scattering tissue phantom [J].
Beard, PC ;
Mills, TN .
BIOMEDICAL OPTOACOUSTICS II, 2001, 4256 :34-42
[3]   Photoacoustic imaging of blood vessel equivalent phantoms [J].
Beard, PC .
BIOMEDICAL OPTOACOUSTICS III, 2002, 4618 :54-62
[4]  
BEARD PC, 1999, PROC SPIE APPL PHYS, V38, P3120
[5]   Optoacoustic imaging using interferometric measurement of surface displacement [J].
Carp, SA ;
Guerra, A ;
Duque, SQ ;
Venugopalan, V .
APPLIED PHYSICS LETTERS, 2004, 85 (23) :5772-5774
[6]   PHASE-SHIFTING SPECKLE INTERFEROMETRY [J].
CREATH, K .
APPLIED OPTICS, 1985, 24 (18) :3053-3058
[7]  
FANG Q, 1991, SPIE, P1553
[8]   High frequency ultrasound imaging with optical arrays [J].
Hamilton, JD ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :216-235
[9]  
HOELEN CGA, 2000, APPL OPTICS
[10]   Optoacoustic imaging using a three-dimensional reconstruction algorithm [J].
Köstli, KP ;
Frauchiger, D ;
Niederhauser, JJ ;
Paltauf, G ;
Weber, HP ;
Frenz, M .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2001, 7 (06) :918-923