Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods

被引:0
|
作者
Nienkemper, Manuel [1 ]
Santel, Natascha [1 ]
Hoenscheid, Ralf [1 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
来源
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE | 2016年 / 77卷 / 04期
关键词
Orthodontics; Skeletal anchorage; Insertion depth; Mini-implants; Models animal; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; DIAMETER; IMPACT;
D O I
10.1007/s00056-016-0036-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 x 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest(A (R)). Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1-100], which increased from 6.95 +/- 2.85 ISQ at 4 mm to 34.63 +/- 5.51 ISQ at 8 mm, and with those of Periotest(A (R)) [periotest values (PTV) range from -8 to 50], which decreased from 13.24 +/- 4.03 PTV to -2.89 +/- 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 +/- 69.32 Nmm to 261 +/- 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest(A (R)) values were highly correlated (r = -0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest(A (R)) yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [41] Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure
    Heo, Yoon-Young
    Cho, Keun-Chul
    Baek, Seung-Hak
    ANGLE ORTHODONTIST, 2012, 82 (05) : 881 - 888
  • [42] Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study
    Romanec, Cristian Liviu
    Panaite, Tinela
    Zetu, Irina Nicoleta
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [43] Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants
    Motoyoshi, Mitsuru
    Yoshida, Tohru
    Ono, Akiko
    Shimizu, Noriyoshi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) : 779 - 784
  • [44] Modal analysis for implant stability assessment: Sensitivity of this methodology for different implant designs
    Zanetti, Elisabetta Maria
    Ciaramella, Stefano
    Cali, Michele
    Pascoletti, Giulia
    Martorelli, Massimo
    Asero, Riccardo
    Watts, David C.
    DENTAL MATERIALS, 2018, 34 (08) : 1235 - 1245
  • [45] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822
  • [46] FEM Analysis of Individualized Polymeric 3D Printed Guide for Orthodontic Mini-Implant Insertion as Temporary Crown Support in the Anterior Maxillary Area
    Nagib, Riham
    Farkas, Andrei Zoltan
    Szuhanek, Camelia
    POLYMERS, 2023, 15 (04)
  • [47] Effects of wobbling angle on the stability measures of orthodontic mini-implants during insertion and removal procedures
    Cho, Il-Sik
    Baek, Sang-Ho
    Kim, Young Ho
    ANGLE ORTHODONTIST, 2013, 83 (06) : 1009 - 1014
  • [48] Comparative Evaluation of Primary Stability of Two Different Types of Orthodontic Mini-Implants
    Jyotirmay, Singh
    Singh, Sanjay Kumar
    Gupta, Abhinav Raj
    Nayak, Subhash Chandra
    Vatsa, Ritesh
    Priyadarshni, Priyanka
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 128 - 131
  • [49] Effects on primary stability of three different techniques for implant site preparation in synthetic bone models of different densities
    Moehlhenrich, S. C.
    Kniha, K.
    Heussen, N.
    Hoelzle, F.
    Modabber, A.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (09) : 980 - 986
  • [50] Pre-drilling force and insertion torques during orthodontic mini-implant insertion in relation to root contact; [Vorbohr-Widerstand und Eindrehmomente bei der Insertion kieferorthopädischer Mini-Implantate in Abhängigkeit zu einem Zahnwurzel-Kontakt]
    Wilmes B.
    Su Y.-Y.
    Sadigh L.
    Drescher D.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2008, 69 (1): : 51 - 58