Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods

被引:0
|
作者
Nienkemper, Manuel [1 ]
Santel, Natascha [1 ]
Hoenscheid, Ralf [1 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
来源
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE | 2016年 / 77卷 / 04期
关键词
Orthodontics; Skeletal anchorage; Insertion depth; Mini-implants; Models animal; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; DIAMETER; IMPACT;
D O I
10.1007/s00056-016-0036-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 x 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest(A (R)). Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1-100], which increased from 6.95 +/- 2.85 ISQ at 4 mm to 34.63 +/- 5.51 ISQ at 8 mm, and with those of Periotest(A (R)) [periotest values (PTV) range from -8 to 50], which decreased from 13.24 +/- 4.03 PTV to -2.89 +/- 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 +/- 69.32 Nmm to 261 +/- 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest(A (R)) values were highly correlated (r = -0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest(A (R)) yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [31] Effect of mini-implant length and diameter on primary stability under loading with two force levels
    Chatzigianni, Athina
    Keilig, Ludger
    Reimann, Susanne
    Eliades, Theodore
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 381 - 387
  • [32] Two-dimensional radiographic and clinical references of the tooth crown for orthodontic mini-implant insertion: A guide-free technique
    Barros, Sergio Estelita
    Janson, Guilherme
    Chiqueto, Kelly
    Garib, Daniela Gamba
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (05): : E8 - E16
  • [33] Impact of Insertion Depth and Predrilling Diameter on Primary Stability of Orthodontic Mini-implants
    Wilmes, Benedict
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2009, 79 (04) : 609 - 614
  • [34] Optimal selections of orthodontic mini-implant diameter and length by biomechanical consideration: A three-dimensional finite element analysis
    Jiang, Lin
    Kong, Liang
    Li, Tao
    Gu, Zexu
    Hou, Rui
    Duan, Yinzhong
    ADVANCES IN ENGINEERING SOFTWARE, 2009, 40 (11) : 1124 - 1130
  • [35] Impact of Implant Design and Bone Properties on the Primary Stability of Orthodontic Mini-Implants
    Redzepagic-Vrazalica, Lejla
    Mesic, Elmedin
    Pervan, Nedim
    Hadziabdic, Vahidin
    Delic, Muamer
    Glusac, Mirza
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 10
  • [36] Influence of Chemically-Modified Implant Surfaces on the Stability of Orthodontic Mini-Implants
    Bratu, Dana Cristina
    Popa, George
    Petrescu, Horatiu
    Karancsi, Olimpiu Ladislau
    Bratu, Emanuel Adrian
    REVISTA DE CHIMIE, 2014, 65 (10): : 1222 - 1225
  • [37] Effects of Drilling Technology on Mini-Implant Primary Stability: A Comparison of the Mechanical Drilling and Femtosecond Laser Ablation
    Zhang, Wenbin
    Alghannam, Fahad
    Zhu, Yingchao
    Zhang, Jianfei
    Wohl, Gregory R.
    Haugen, Harold K.
    Qin, Zhipeng
    Xie, Guoqiang
    Fang, Qiyin
    Shen, Steve Guofang
    FRONTIERS IN PHYSICS, 2021, 9
  • [38] Machine-Driven Versus Manual Insertion Mode: Influence on Primary Stability of Orthodontic Mini-Implants
    Novsak, Domen
    Zrinski, Magda Trinajstic
    Spalj, Stjepan
    IMPLANT DENTISTRY, 2015, 24 (01) : 31 - 36
  • [39] Effect of insertion angle on the stability of orthodontic mini-implants in a rabbit tibia model: A finite element analysis
    Araujo-Monsalvo, Victor M.
    Gonzalez-Areas, Mercy G.
    Martinez-Coria, Elisa
    Flores-Cuamatzi, Enrique
    Araujo-Monsalvo, Benjamin
    Dominguez-Hernandez, Victor M.
    CIRUGIA Y CIRUJANOS, 2019, 87 (02): : 190 - 195
  • [40] Three-dimensional evaluation of tooth movement in Class II malocclusions treated without extraction by orthodontic mini-implant anchorage
    Ali, Dler
    Mohammed, Hnd
    Koo, Seung-Hwan
    Kang, Kyung-Hwa
    Kim, Sang-Cheol
    KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (05) : 280 - 289