Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods

被引:0
|
作者
Nienkemper, Manuel [1 ]
Santel, Natascha [1 ]
Hoenscheid, Ralf [1 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
来源
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE | 2016年 / 77卷 / 04期
关键词
Orthodontics; Skeletal anchorage; Insertion depth; Mini-implants; Models animal; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; DIAMETER; IMPACT;
D O I
10.1007/s00056-016-0036-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 x 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest(A (R)). Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1-100], which increased from 6.95 +/- 2.85 ISQ at 4 mm to 34.63 +/- 5.51 ISQ at 8 mm, and with those of Periotest(A (R)) [periotest values (PTV) range from -8 to 50], which decreased from 13.24 +/- 4.03 PTV to -2.89 +/- 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 +/- 69.32 Nmm to 261 +/- 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest(A (R)) values were highly correlated (r = -0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest(A (R)) yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [21] Pre-drilling force and insertion torques during orthodontic mini-implant insertion in relation to root contact
    Wilmes, Benedict
    Su, Yu-Yu
    Sadigh, Lilian
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 51 - 58
  • [22] Finite element analysis of mono- and bicortical mini-implant stability
    Holberg, Christof
    Winterhalder, Philipp
    Rudzki-Janson, Ingrid
    Wichelhaus, Andrea
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (05) : 550 - 556
  • [23] Primary stability and viscoelastic displacement of mini-implant system under loading
    Lee, Jim
    Jeong, Yong-Hoon
    Pittman, Joseph
    Deguchi, Toru
    Johnston, William M.
    Fields, Henry W.
    Kim, Do-Gyoon
    CLINICAL BIOMECHANICS, 2017, 41 : 28 - 33
  • [24] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Zhang, Bo
    Huang, Xinqi
    Huo, Sibei
    Zhang, Chenghao
    Cen, Xiao
    Zhao, Zhihe
    LASERS IN MEDICAL SCIENCE, 2021, 36 (08) : 1557 - 1566
  • [25] The Effect of Insertion Angles and Depths of Dental Implant on the Initial Stability
    Wu, Hsiang-Chun
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    APPLIED SCIENCES-BASEL, 2020, 10 (09):
  • [26] Measurement of Dental Implant Stability by Two Different Techniques
    Kocak-Buyukdere, A.
    Kayabay, G.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (07) : 973 - 977
  • [27] Three-dimensional digital imaging analysis of the palatal bone thickness for orthodontic mini-implant insertion - determination of the safe zone and angulation
    Schubert, Hanna
    Matta, Ragai
    Seidel, Anna
    Adler, Werner
    Wichmann, Manfred
    Kesting, Marco
    Lutz, Rainer
    BMC ORAL HEALTH, 2024, 24 (01):
  • [28] Assessment of Potential Orthodontic Mini-implant Insertion Sites Based on Anatomical Hard Tissue Parameters: A Systematic Review
    AlSamak, Saeed
    Gkantidis, Nikolaos
    Bitsanis, Elias
    Christou, Panagiotis
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 875 - 887
  • [29] Impact of implant design on primary stability of orthodontic mini-implants
    Wilmes, Benedict
    Ottenstreuer, Stephanie
    Su, Yu-Yu
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 42 - 50
  • [30] Automatic Segmentation of the Jaws Used in Guided Insertion of Orthodontic Mini Implants to Improve Their Stability and Precision
    David, Andra Patricia
    Brad, Silviu
    Rusu, Laura-Cristina
    David, Ovidiu Tiberiu
    Samoila, Christian
    Leretter, Marius Traian
    MEDICINA-LITHUANIA, 2024, 60 (10):