Slit-scanning differential x-ray phase-contrast mammography: Proof-of-concept experimental studies

被引:64
作者
Koehler, Thomas [1 ]
Daerr, Heiner [1 ]
Martens, Gerhard [1 ]
Kuhn, Norbert [1 ]
Loescher, Stefan [1 ]
van Stevendaal, Udo [1 ]
Roessl, Ewald [1 ]
机构
[1] Philips Res Labs, D-22335 Hamburg, Germany
关键词
differential phase-contrast imaging; grating interferometry; full-field digital mammography; INTERFEROMETRY; TOMOGRAPHY;
D O I
10.1118/1.4914420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to investigate the feasibility of grating-based, differential phase-contrast, full-field digital mammography (FFDM) in terms of the requirements for field-of-view (FOV), mechanical stability, and scan time. Methods: A rigid, actuator-free Talbot interferometric unit was designed and integrated into a state-of-the-art x-ray slit-scanning mammography system, namely, the Philips MicroDose L30 FFDM system. A dedicated phase-acquisition and phase retrieval method was developed and implemented that exploits the redundancy of the data acquisition inherent to the slit-scanning approach to image generation of the system. No modifications to the scan arm motion control were implemented. Results: The authors achieve a FOV of 160x196 mm consisting of two disjoint areas measuring 77x196 mm with a gap of 6 mm between them. Typical scanning times vary between 10 and 15 s and dose levels are lower than typical FFDM doses for conventional scans with identical acquisition parameters due to the presence of the source-grating G(0). Only minor to moderate artifacts are observed in the three reconstructed images, indicating that mechanical vibrations induced by other system components do not prevent the use of the platform for phase contrast imaging. Conclusions: To the best of our knowledge, this is the first attempt to integrate x-ray gratings hardware into a clinical mammography unit. The results demonstrate that a scanning differential phase contrast FFDM system that meets the requirements of FOV, stability, scan time, and dose can be build. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1959 / 1965
页数:7
相关论文
共 30 条
  • [11] Photon-Counting Spectral Phase-Contrast Mammography
    Fredenberg, E.
    Roessl, E.
    Koehler, T.
    van Stevendaal, U.
    Schulze-Wenck, I.
    Wieberneit, N.
    Stampanoni, M.
    Wang, Z.
    Kubik-Huch, R. A.
    Hauser, N.
    Lundqvist, M.
    Danielsson, M.
    Aslund, M.
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [12] Fredenberg E., 2009, P SOC PHOTO-OPT INS, V7258
  • [13] A Study on Mastectomy Samples to Evaluate Breast Imaging Quality and Potential Clinical Relevance of Differential Phase Contrast Mammography
    Hauser, Nik
    Wang, Zhentian
    Kubik-Huch, Rahel A.
    Trippel, Mafalda
    Singer, Gad
    Hohl, Michael K.
    Roessl, Ewald
    Koehler, Thomas
    van Stevendaal, Udo
    Wieberneit, Nataly
    Stampanoni, Marco
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (03) : 131 - 137
  • [14] Phase contrast X-ray imaging of large samples using an incoherent laboratory source
    Kottler, C.
    Pfeiffer, F.
    Bunk, O.
    Gruenzweig, C.
    Bruder, J.
    Kaufmann, R.
    Tlustos, L.
    Walt, H.
    Briod, I.
    Weitkamp, T.
    David, C.
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (08): : 2728 - 2733
  • [15] Grating interferometer based scanning setup for hard x-ray phase contrast imaging
    Kottler, C.
    Pfeiffer, F.
    Bunk, O.
    Gruenzweig, C.
    David, C.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04)
  • [16] Motionless phase stepping in X-ray phase contrast imaging with a compact source
    Miao, Houxun
    Chen, Lei
    Bennett, Eric E.
    Adamo, Nick M.
    Gomella, Andrew A.
    DeLuca, Alexa M.
    Patel, Ajay
    Morgan, Nicole Y.
    Wen, Han
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (48) : 19268 - 19272
  • [17] On a dark-field signal generated by micrometer-sized calcifications in phase-contrast mammography
    Michel, Thilo
    Rieger, Jens
    Anton, Gisela
    Bayer, Florian
    Beckmann, Matthias W.
    Durst, Juergen
    Fasching, Peter A.
    Haas, Wilhelm
    Hartmann, Arndt
    Pelzer, Georg
    Radicke, Marcus
    Rauh, Claudia
    Ritter, Andre
    Sievers, Peter
    Schulz-Wendtland, Ruediger
    Uder, Michael
    Wachter, David L.
    Weber, Thomas
    Wenkel, Evelyn
    Zang, Andrea
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (08) : 2713 - 2732
  • [18] Demonstration of X-Ray Talbot interferometry
    Momose, A
    Kawamoto, S
    Koyama, I
    Hamaishi, Y
    Takai, K
    Suzuki, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (7B): : L866 - L868
  • [19] X-ray phase imaging: from synchrotron to hospital
    Momose, Atsushi
    Yashiro, Wataru
    Kido, Kazuhiro
    Kiyohara, Junko
    Makifuchi, Chiho
    Ito, Tsukasa
    Nagatsuka, Sumiya
    Honda, Chika
    Noda, Daiji
    Hattori, Tadashi
    Endo, Tokiko
    Nagashima, Masabumi
    Tanaka, Junji
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [20] Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm
    Momose, Atsushi
    Yashiro, Wataru
    Harasse, Sebastien
    Kuwabara, Hiroaki
    [J]. OPTICS EXPRESS, 2011, 19 (09): : 8423 - 8432