Slit-scanning differential x-ray phase-contrast mammography: Proof-of-concept experimental studies

被引:64
作者
Koehler, Thomas [1 ]
Daerr, Heiner [1 ]
Martens, Gerhard [1 ]
Kuhn, Norbert [1 ]
Loescher, Stefan [1 ]
van Stevendaal, Udo [1 ]
Roessl, Ewald [1 ]
机构
[1] Philips Res Labs, D-22335 Hamburg, Germany
关键词
differential phase-contrast imaging; grating interferometry; full-field digital mammography; INTERFEROMETRY; TOMOGRAPHY;
D O I
10.1118/1.4914420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to investigate the feasibility of grating-based, differential phase-contrast, full-field digital mammography (FFDM) in terms of the requirements for field-of-view (FOV), mechanical stability, and scan time. Methods: A rigid, actuator-free Talbot interferometric unit was designed and integrated into a state-of-the-art x-ray slit-scanning mammography system, namely, the Philips MicroDose L30 FFDM system. A dedicated phase-acquisition and phase retrieval method was developed and implemented that exploits the redundancy of the data acquisition inherent to the slit-scanning approach to image generation of the system. No modifications to the scan arm motion control were implemented. Results: The authors achieve a FOV of 160x196 mm consisting of two disjoint areas measuring 77x196 mm with a gap of 6 mm between them. Typical scanning times vary between 10 and 15 s and dose levels are lower than typical FFDM doses for conventional scans with identical acquisition parameters due to the presence of the source-grating G(0). Only minor to moderate artifacts are observed in the three reconstructed images, indicating that mechanical vibrations induced by other system components do not prevent the use of the platform for phase contrast imaging. Conclusions: To the best of our knowledge, this is the first attempt to integrate x-ray gratings hardware into a clinical mammography unit. The results demonstrate that a scanning differential phase contrast FFDM system that meets the requirements of FOV, stability, scan time, and dose can be build. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1959 / 1965
页数:7
相关论文
共 30 条
  • [1] [Anonymous], 2008, 08022 CEP
  • [2] Scatter rejection in multislit digital mammography
    Åslund, M
    Cederström, B
    Lundqvist, M
    Danielsson, M
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 933 - 940
  • [3] Detectors for the future of X-ray imaging
    Aslund, M.
    Fredenberg, E.
    Telman, M.
    Danielsson, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 327 - 333
  • [4] Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors
    Aslund, Magnus
    Cederstrom, Bjorn
    Lundqvist, Mats
    Danielsson, Mats
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 1918 - 1925
  • [5] Egocentric Fairness Perception: Emotional Reactions and Individual Differences in Overt Responses
    Bediou, Benoit
    Scherer, Klaus R.
    [J]. PLOS ONE, 2014, 9 (02):
  • [6] Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Qi, Zhihua
    Chen, Guang-Hong
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 424 - 428
  • [7] X-ray phase-contrast imaging: from pre-clinical applications towards clinics
    Bravin, Alberto
    Coan, Paola
    Suortti, Pekka
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) : R1 - R35
  • [8] Bushberg J.T., 2012, ESSENTIAL PHYS MED I, V3
  • [9] Endo Tokiko, 2014, Breast Imaging. 12th International Workshop, IWDM 2014. Proceedings: LNCS 8539, P488, DOI 10.1007/978-3-319-07887-8_68
  • [10] Phase Unwrapping in Spectral X-Ray Differential Phase-Contrast Imaging With an Energy-Resolving Photon-Counting Pixel Detector
    Epple, Franz M.
    Ehn, Sebastian
    Thibault, Pierre
    Koehler, Thomas
    Potdevin, Guillaume
    Herzen, Julia
    Pennicard, David
    Graafsma, Heinz
    Noel, Peter B.
    Pfeiffer, Franz
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 816 - 823