An improved PCR method for detection of HIV-1 proviral DNA of a wide range of subtypes and recombinant forms circulating globally

被引:3
|
作者
Weidner, Juergen [1 ]
Cassens, Uwe [2 ]
Goehde, Wolfgang [3 ]
Sibrowski, Walter [4 ]
Odaibo, Georgina [5 ]
Olaleye, David [5 ]
Reichelt, Doris [6 ]
Greve, Burkhard [7 ]
机构
[1] Partec GmbH, D-02828 Gorlitz, Germany
[2] Klinikum Dortmund gGmbH, Lab Med & Med Microbiol, Inst Transfus Med, D-44137 Dortmund, Germany
[3] Univ Hosp Munster, Fac Med, D-48149 Munster, Germany
[4] Univ Hosp Munster, Dept Transfus Med, D-48149 Munster, Germany
[5] Univ Ibadan, Coll Med, Dept Virol, Ibadan, Nigeria
[6] Univ Hosp Munster, Dept Internal Med, D-48149 Munster, Germany
[7] Univ Hosp Munster, Dept Radiotherapy Radiooncol, D-48149 Munster, Germany
关键词
HIV-1; PCR; Subtypes; DNA; Provirus; IMMUNODEFICIENCY-VIRUS TYPE-1; POLYMERASE-CHAIN-REACTION; ANTIRETROVIRAL THERAPY; TOUCHDOWN PCR; BLOOD-SAMPLES; VIRAL LOAD; T-CELLS; NO-LYSE; QUANTIFICATION; AMPLIFICATION;
D O I
10.1016/j.jviromet.2010.12.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Proviral DNAs are being measured increasingly as a marker of the efficacy of highly active anti-retroviral therapy (HAART) and is accepted for the early diagnosis of perinatal HIV-1 infections. This requires a standardized test which enables the detection of a wide range of subtypes worldwide including O, N and circulating recombinant forms (CRFs). Based on a previous publication, a PCR - Test for HIV-1 provirus detection in peripheral blood mononuclear cells (PBMCs) was developed. Blood samples from 80 individuals infected with HIV-1 and 20 persons negative for HIV-1&2 from Africa and Germany were tested for the presence of HIV-1 provirus DNA. The primer system used enables the detection of proviral DNA despite the high concentrations of human DNA. The limit of detection was determined to be 5 copies per 10(5) cells. All 20 samples from persons negative for HIV were negative for HIV-1 proviral DNA while provirus DNA was amplified from 76 of the 80(95%) samples from persons infected with HIV. The amplified products were detected by gel-electrophoresis, flow cytometry and real-time PCR All three detection systems provided the same results. (C) 2010 Elsevier RV. All rights reserved.
引用
收藏
页码:22 / 26
页数:5
相关论文
共 50 条
  • [31] Rapid Detection of HIV-1 Proviral DNA for Early Infant Diagnosis Using Recombinase Polymerase Amplification
    Boyle, David S.
    Lehman, Dara A.
    Lillis, Lorraine
    Peterson, Dylan
    Singhal, Mitra
    Armes, Niall
    Parker, Mathew
    Piepenburg, Olaf
    Overbaugh, Julie
    MBIO, 2013, 4 (02):
  • [32] Flow cytometry in situ polymerase chain reaction as an innovative approach to HIV-1 proviral DNA detection
    Gibellini, D
    Zauli, G
    Re, MC
    Furlini, G
    La Placa, M
    EUROPEAN JOURNAL OF HISTOCHEMISTRY, 1998, 42 (02): : 137 - 141
  • [33] COLORIMETRIC DETECTION FOR PCR AMPLIFIED HIV-1 DNA USING MAGNETIC BEADS
    SUZUKI, K
    OKAMOTO, N
    KANO, T
    JOURNAL OF VIROLOGICAL METHODS, 1993, 41 (03) : 341 - 350
  • [34] HIV-1 transmission between MSM and heterosexuals, and increasing proportions of circulating recombinant forms in the Nordic Countries
    Esbjornsson, Joakim
    Mild, Mattias
    Audelin, Anne
    Fonager, Jannik
    Skar, Helena
    Jorgensen, Louise Bruun
    Liitsola, Kirsi
    Bjorkman, Per
    Bratt, Goran
    Gisslen, Magnus
    Sonnerborg, Anders
    Nielsen, Claus
    Medstrand, Patrik
    Albert, Jan
    VIRUS EVOLUTION, 2016, 2 (01)
  • [35] IMPROVED DETECTION OF HIV-1 ENVELOPE SEQUENCES USING OPTIMIZED PCR AND INOSINE-SUBSTITUTED PRIMERS
    CASSOL, S
    SALAS, T
    LAPOINTE, N
    ARELLA, M
    RUDNIK, J
    OSHAUGHNESSY, M
    MOLECULAR AND CELLULAR PROBES, 1991, 5 (02) : 157 - 160
  • [36] Clinical, epidemiological and molecular features of the HIV-1 subtype C and recombinant forms that are circulating in the city of São Paulo, Brazil
    Rosana Alcalde
    Monick L Guimarães
    Alberto JS Duarte
    Jorge Casseb
    Virology Journal, 9
  • [37] DETECTION OF HIV-1 DNA BY PCR - EVALUATION OF PRIMER PAIR CONCORDANCE AND SENSITIVITY OF A SINGLE PRIMER PAIR
    LYNCH, CE
    MADEJ, R
    LOUIE, PH
    RODGERS, G
    JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1992, 5 (05): : 433 - 440
  • [38] Time-scale of minor HIV-1 complex circulating recombinant forms from Central and West Africa
    Edson Delatorre
    Gonzalo Bello
    BMC Evolutionary Biology, 16
  • [39] Time-scale of minor HIV-1 complex circulating recombinant forms from Central and West Africa
    Delatorre, Edson
    Bello, Gonzalo
    BMC EVOLUTIONARY BIOLOGY, 2016, 16
  • [40] Evaluation of a prototype Amplicor PCR assay for detection of human immunodeficiency virus type 1 DNA in blood samples from Tanzanian adults infected with HIV-1 subtypes A, C and D
    Lyamuya, E
    Olausson-Hansson, E
    Albert, J
    Mhalu, F
    Biberfeld, G
    JOURNAL OF CLINICAL VIROLOGY, 2000, 17 (01) : 57 - 63