Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

被引:31
|
作者
Iffa, Emishaw [1 ]
Hun, Diana [1 ]
Salonvaara, Mikael [1 ]
Shrestha, Som [1 ]
Lapsa, Melissa [2 ]
机构
[1] Oak Ridge Natl Lab, Bldg Envelope Mat Res Grp, Bldg & Transportat Sci, Oak Ridge, TN 37830 USA
[2] Oak Ridge Natl Lab, Energy Sci & Technol Directorate, Bldg Technol Program, Oak Ridge, TN USA
关键词
Active insulation system; Convective water loop; Cooling load; Heat flux; Hydronic system; Peak-load; Thermal energy storage; EMBEDDED BUILDING ENVELOPE; COOLING SYSTEMS; EFFICIENCY; WATER; SIMULATION; COMFORT; CLIMATE; SAVINGS;
D O I
10.1016/j.est.2021.103815
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The per-formances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m(2). The active insulation system's dynamic R-value varied between less than 1ft2 center dot degrees F.h/BTU (0.18 m(2).K/W) to 98% of the equally thick foam insulation's R-value.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Thermal performance evaluation of cellulose fibre as building insulation material
    Pal, Ravinder Kumar
    Goyal, Parveen
    Sehgal, Shankar
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2022, 29 (03) : 345 - 354
  • [42] Thermal performance evaluation of a solar air heater with and without thermal energy storage
    Tyagi, V. V.
    Pandey, A. K.
    Kaushik, S. C.
    Tyagi, S. K.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 107 (03) : 1345 - 1352
  • [43] RECIPROCATING FLOW FOR ENHANCING THERMAL PERFORMANCE OF LATENT THERMAL ENERGY STORAGE SYSTEMS
    Virk, Akashdeep Singh
    Park, Chanwoo
    Mitsingas, Constandinos
    Kweon, Chol-Bum
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 11, 2021,
  • [44] Dynamic Simulation and Analysis for Thermal Insulation and Heat Preservation of Wall
    Wang, Xuejin
    Zhang, Zhihong
    Chen, Zhonghai
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 396 - 401
  • [45] Thermal performance improvement of thermal energy storage systems by employing a contrastive experiment
    Zou, Junlong
    He, Fan
    Qi, Yunyang
    Meng, Xi
    Ma, Wenkai
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 41
  • [46] Characterization of a Wall System with Dynamic Thermal Insulation-Experimental Campaign and Numerical Simulation
    Almeida, Ricardo M. S. F.
    Teles-Ribeiro, Maria
    Barreira, Eva
    ENERGIES, 2023, 16 (17)
  • [47] Thermodynamic analyses and assessments of various thermal energy storage systems for buildings
    Caliskan, Hakan
    Dincer, Ibrahim
    Hepbasli, Arif
    ENERGY CONVERSION AND MANAGEMENT, 2012, 62 : 109 - 122
  • [48] Experimental evaluation of the thermal performance of coir mat and green facade as wall insulation in a tropical climate
    Kumar, T. S. Sigi
    Shafi, K. A.
    Thomas, Rijo Jacob
    Mohammed, Jesna
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 40
  • [49] An advanced wall treatment for a 1D model of packed bed thermal energy storage systems
    Contestabile, F.
    Cornolti, L.
    Zavattoni, S.
    Barbato, M. C.
    JOURNAL OF ENERGY STORAGE, 2019, 26
  • [50] Assessment of the Thermal Energy Storage in Friedrichshafen District Energy Systems
    Rezaie, Behnaz
    Reddy, Bale V.
    Rosen, Marc A.
    15TH INTERNATIONAL SYMPOSIUM ON DISTRICT HEATING AND COOLING (DHC15-2016), 2017, 116 : 91 - 105