VCSEL technology for medical diagnostics and therapeutics

被引:10
作者
Hibbs-Brenner, M. K. [1 ]
Johnson, K. L. [1 ]
Bendett, M. [2 ]
机构
[1] Vixar, 15350 25th Ave N,Suite 110, Plymouth, MN 55447 USA
[2] Lockheed Martin Aculight, Bothell, WA 98021 USA
来源
PHOTONS AND NEURONS | 2009年 / 7180卷
关键词
VCSEL; Vertical Cavity Surface Emitting Laser; neurostimulation; biomedical sensor; near infra-red; red; CARDIAC MARKERS; STIMULATION; LASERS; POINT;
D O I
10.1117/12.815307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the 1990's a new laser technology, Vertical Cavity Surface Emitting Lasers, or VCSELs, emerged and transformed the data communication industry. The combination of performance characteristics, reliability and performance/cost ratio allowed high data rate communication to occur over short distances at a commercially viable price. VCSELs have not been widely used outside of this application space, but with the development of new attributes, such as a wider range of available wavelengths, the demonstration of arrays of VCSELs on a single chip, and a variety of package form factors, VCSELs can have a significant impact on medical diagnostic and therapeutic applications. One area of potential application is neurostimulation. Researchers have previously demonstrated the feasibility of using 1850nm light for nerve stimulation. The ability to create an array of VCSELs emitting at this wavelength would allow significantly improved spatial resolution, and multiple parallel channels of stimulation. For instance, 2D arrays of 100 lasers or more can be integrated on a single chip less than 2mm on a side. A second area of interest is non-invasive sensing. Performance attributes such as the narrow spectral width, low power consumption, and packaging flexibility open up new possibilities in non-invasive and/or continuous sensing. This paper will suggest ways in which VCSELs can be implemented within these application areas, and the advantages provided by the unique performance characteristics of the VCSEL. The status of VCSEL technology as a function of available wavelength and array size and form factors will be summarized.
引用
收藏
页数:10
相关论文
共 35 条
  • [21] Lee Brian W., 2008, V414, P109
  • [22] DEEP-RED CONTINUOUS WAVE TOP-SURFACE-EMITTING VERTICAL-CAVITY ALGAAS SUPERLATTICE LASERS
    LEE, YH
    TELL, B
    BROWNGOEBELER, KF
    LEIBENGUTH, RE
    MATTERA, VD
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 1991, 3 (02) : 108 - 109
  • [23] Matsushima JI, 1997, ADV OTO-RHINO-LARYNG, V52, P106
  • [24] Noninvasive method for measuring local hemoglobin oxygen saturation in tissue using wide gap second derivative near-infrared spectroscopy
    Myers, DE
    Anderson, LD
    Seifert, RP
    Ortner, JP
    Cooper, CE
    Beilman, GJ
    Mowlem, JD
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)
  • [25] Can ultrasound be used to stimulate nerve tissue?
    Norton, Stephen J.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2003, 2 (1)
  • [26] A MODEL OF SAFE LEVELS FOR ELECTRICAL-STIMULATION
    SHANNON, RV
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (04) : 424 - 426
  • [27] Vertical-cavity surface-emitting laser diodes at 1.55 μm with large output power and high operation temperature
    Shau, R
    Ortsiefer, M
    Rosskopf, J
    Böhm, G
    Köhler, F
    Amann, MC
    [J]. ELECTRONICS LETTERS, 2001, 37 (21) : 1295 - 1296
  • [28] 780nm oxidised vertical-cavity surface-emitting lasers with Al0.11Ga0.89As quantum wells
    Shin, HE
    Ju, YG
    Shin, JH
    Ser, JH
    Kim, T
    Lee, EK
    Kim, I
    Lee, YH
    [J]. ELECTRONICS LETTERS, 1996, 32 (14) : 1287 - 1288
  • [29] Pulse oximetry: Principles and limitations
    Sinex, JE
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1999, 17 (01) : 59 - 66
  • [30] GAINASP-INP SURFACE EMITTING INJECTION-LASERS
    SODA, H
    IGA, K
    KITAHARA, C
    SUEMATSU, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 1979, 18 (12) : 2329 - 2330