VCSEL technology for medical diagnostics and therapeutics

被引:10
作者
Hibbs-Brenner, M. K. [1 ]
Johnson, K. L. [1 ]
Bendett, M. [2 ]
机构
[1] Vixar, 15350 25th Ave N,Suite 110, Plymouth, MN 55447 USA
[2] Lockheed Martin Aculight, Bothell, WA 98021 USA
来源
PHOTONS AND NEURONS | 2009年 / 7180卷
关键词
VCSEL; Vertical Cavity Surface Emitting Laser; neurostimulation; biomedical sensor; near infra-red; red; CARDIAC MARKERS; STIMULATION; LASERS; POINT;
D O I
10.1117/12.815307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the 1990's a new laser technology, Vertical Cavity Surface Emitting Lasers, or VCSELs, emerged and transformed the data communication industry. The combination of performance characteristics, reliability and performance/cost ratio allowed high data rate communication to occur over short distances at a commercially viable price. VCSELs have not been widely used outside of this application space, but with the development of new attributes, such as a wider range of available wavelengths, the demonstration of arrays of VCSELs on a single chip, and a variety of package form factors, VCSELs can have a significant impact on medical diagnostic and therapeutic applications. One area of potential application is neurostimulation. Researchers have previously demonstrated the feasibility of using 1850nm light for nerve stimulation. The ability to create an array of VCSELs emitting at this wavelength would allow significantly improved spatial resolution, and multiple parallel channels of stimulation. For instance, 2D arrays of 100 lasers or more can be integrated on a single chip less than 2mm on a side. A second area of interest is non-invasive sensing. Performance attributes such as the narrow spectral width, low power consumption, and packaging flexibility open up new possibilities in non-invasive and/or continuous sensing. This paper will suggest ways in which VCSELs can be implemented within these application areas, and the advantages provided by the unique performance characteristics of the VCSEL. The status of VCSEL technology as a function of available wavelength and array size and form factors will be summarized.
引用
收藏
页数:10
相关论文
共 35 条
  • [1] Innovations in the Management of Cerebral Injury
    Albano, Corazon
    Comandante, Laura
    Nolan, Scot
    [J]. CRITICAL CARE NURSING QUARTERLY, 2005, 28 (02) : 135 - 149
  • [2] [Anonymous], 2006, EE TIMES
  • [3] The measurement of dyshemoglobins and total hemoglobin by pulse oximetry
    Barker, Steven J.
    Badal, John J.
    [J]. CURRENT OPINION IN ANESTHESIOLOGY, 2008, 21 (06) : 805 - 810
  • [4] CRITERIA FOR SELECTING ELECTRODES FOR ELECTRICAL-STIMULATION - THEORETICAL AND PRACTICAL CONSIDERATIONS
    BRUMMER, SB
    ROBBLEE, LS
    HAMBRECHT, FT
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) : 159 - 171
  • [5] Cheng XF, 2004, CLIN HEMORHEOL MICRO, V31, P11
  • [6] Room temperature continuous wave InGaAsN quantum well vertical-cavity lasers emitting at 1.3 μm
    Choquette, KD
    Klem, JF
    Fischer, AJ
    Blum, O
    Allerman, AA
    Fritz, IJ
    Kurtz, SR
    Breiland, WG
    Sieg, R
    Geib, KM
    Scott, JW
    Naone, RL
    [J]. ELECTRONICS LETTERS, 2000, 36 (16) : 1388 - 1390
  • [7] COUNTER SA, 1993, SCAND AUDIOL, V22, P1
  • [8] CRAWFORD MH, 1998, OSA TRENDS OPTICS PH, V15, P104
  • [9] Fritsch G.a.H., 1870, ARCH F ANAT PHYSL, V37, P300
  • [10] Galvani L, 1791, Commentarii de Bononiensi Scientiarum et Artium Instituto Atque Academia, V7, P363, DOI DOI 10.1097/00000441-195402000-00023