Sulfadiazine-selective determination in aquaculture environment: Selective potentiometric transduction by neutral or charged ionophores

被引:28
作者
Almeida, S. A. A. [1 ,2 ,3 ]
Heitor, A. M. [2 ]
Montenegro, M. C. B. S. M. [3 ]
Sales, M. G. F. [1 ]
机构
[1] Inst Super Engn Porto, BioMark ISEP, Oporto, Portugal
[2] Inst Nacl Saude Dr Ricardo Jorge Porto, INSA Porto, Oporto, Portugal
[3] Univ Porto, Fac Farm, REQUIMTE Dept Ciencias Quim, P-4100 Oporto, Portugal
关键词
Sulphadiazine; Cyclodextrin-based ionophore; Porphyrin-based ionophore; Sensor; Potentiometry; SULFONAMIDE ANTIBIOTICS; PHARMACEUTICAL ANALYSIS; ELECTRODES; IMMUNOSENSOR; PORPHYRINS; CHEMISTRY; MEMBRANES;
D O I
10.1016/j.talanta.2011.06.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, alpha-cyclodextrin, beta-cyclodextrin, or gamma-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade(-1) and detection limits of 3.91 x 10(-5) mol L-1. The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7-62.0 mV decade(-1) and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2-7. The sensors displayed fast response, always <15 s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1508 / 1516
页数:9
相关论文
共 48 条
[1]   Waveguide interrogated optical immunosensor (WIOS) for detection of sulfonamide antibiotics in milk [J].
Adrian, Javier ;
Pasche, Stephanie ;
Diserens, Jean-Marc ;
Sanchez-Baeza, Francisco ;
Gao, Hui ;
Marco, M. -Pilar ;
Voirin, Guy .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3340-3346
[2]   Mapping of the cyclodextrin cavity using the cylindrical coordinate system [J].
Akimoto, T .
YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2005, 125 (12) :971-980
[3]  
AMEMIYA S, 2007, HDB ELECTOCHEMISTRY, pCH7
[4]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[5]  
[Anonymous], 2007, Core Concepts in Supramolecular Chemistry and Nanochemistry
[6]  
[Anonymous], 2006, Encyclopedia of sensors, potentiometric ion sensors
[7]  
Antonisse MMG, 1999, ELECTROANAL, V11, P1035, DOI 10.1002/(SICI)1521-4109(199910)11:14<1035::AID-ELAN1035>3.3.CO
[8]  
2-9
[9]   Chemically modified field effect transistors with nitrite or fluoride selectivity [J].
Antonisse, MMG ;
Snellink-Ruel, BHM ;
Engbersen, JFJ ;
Reinhoudt, DN .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1998, (04) :773-777
[10]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890