A High-Rate Energy-Resolving Photon-Counting ASIC for Spectral Computed Tomography

被引:34
作者
Gustavsson, Mikael [1 ]
Ul Amin, Farooq [2 ]
Bjorklid, Anders [1 ]
Ehliar, Andreas [2 ]
Xu, Cheng [3 ]
Svensson, Christer [2 ]
机构
[1] SP Devices AB, S-58330 Linkoping, Sweden
[2] Linkoping Univ, Dept Elect Engn, S-58183 Linkoping, Sweden
[3] Royal Inst Technol, Dept Phys, S-10044 Stockholm, Sweden
关键词
CMOS; photon counting; spectral computed tomography; x-ray detection; PIXEL READOUT CHIP; DETECTOR; PERFORMANCE;
D O I
10.1109/TNS.2011.2169811
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe a high-rate energy-resolving photon-counting ASIC aimed for spectral computed tomography. The chip has 160 channels and 8 energy bins per channel. It demonstrates a noise level of ENC= electrons at 5 pF input load at a power consumption of <5mW/channel. Maximum count rate is 17 Mcps at a peak time of 40 ns, made possible through a new filter reset scheme, and maximum read-out frame rate is 37 kframe/s.
引用
收藏
页码:30 / 39
页数:10
相关论文
共 27 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]  
Amin F. U., 2010, 2010 MIXDES - 17th International Conference "Mixed Design of Integrated Circuits & Systems", P289
[3]  
[Anonymous], MATLAB
[4]  
[Anonymous], P SPIE
[5]  
[Anonymous], IEEE T NUCL SCI
[6]  
[Anonymous], P SPIE
[7]   LVDS I/O interface for Gb/s-per-pin operation in 0.35-μm CMOS [J].
Boni, A ;
Pierazzi, A ;
Vecchi, D .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2001, 36 (04) :706-711
[8]   Design considerations to overcome cross talk in a photon counting silicon strip detector for computed tomography [J].
Bornefalk, Hans ;
Xu, Cheng ;
Svensson, Christer ;
Danielsson, Mats .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3) :371-378
[9]   Imaging performance of the hybrid pixel detectors XPAD3-S [J].
Brunner, F. Cassol ;
Clemens, J. C. ;
Hemmer, C. ;
Morel, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06) :1773-1789
[10]   Detective quantum efficiency dependence on x-ray energy weighting in mammography [J].
Cahn, RN ;
Cederström, B ;
Danielsson, M ;
Hall, A ;
Lundqvist, M ;
Nygren, D .
MEDICAL PHYSICS, 1999, 26 (12) :2680-2683