The Effect of Ultrasonic Scaling and Air-Powder Polishing on the Roughness of the Enamel, Three Different Nanocomposites, and Composite/Enamel and Composite/Cementum Interfaces

被引:13
作者
Babina, Ksenia [1 ]
Polyakova, Maria [1 ]
Sokhova, Inna [1 ]
Doroshina, Vladlena [1 ]
Arakelyan, Marianna [1 ]
Zaytsev, Alexandr [2 ]
Novozhilova, Nina [1 ]
机构
[1] IM Sechenov First Moscow State Med Univ, Dept Therapeut Dent, Sechenov Univ, Moscow 119991, Russia
[2] IM Sechenov First Moscow State Med Univ, Inst Linguist & Intercultural Commun, Sechenov Univ, Moscow 119991, Russia
关键词
surface roughness; ultrasonic scaling; air-powder polishing; nanocomposite resins; composite/enamel interface; composite/cementum interface; COLORED RESTORATIVE MATERIALS; SURFACE-ROUGHNESS; MAINTENANCE PROCEDURES; PERIODONTAL-DISEASES; RESIN COMPOSITE; PARAMETERS; DEVICES;
D O I
10.3390/nano11113072
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We aimed to assess the effects of ultrasonic scaling and air-powder polishing on the roughness of enamel, three nanocomposites (Premise, Herculite Ultra, Harmonize), and composite/enamel and composite/cementum interfaces. Class V cavities were restored in 99 extracted third molars with one of the three nanocomposites and treated with ultrasonic scaler or air-powder polishing device (calcium carbonate or sodium bicarbonate powders). The roughness (Ra) of the investigated surfaces was measured with contact profilometer before and after treatment. The data were analyzed using repeated measures ANOVA. Specimens' Ra values before instrumentation were near the clinically acceptable 0.2 mu m threshold. All techniques increased the roughness of the tested surfaces; however, the enamel was slightly affected. The mean Ra values after prophylaxis for composite, composite/cementum and composite/enamel surfaces were 0.32-0.55, 1.33-1.73, and 1.25-1.36, respectively. The extent of composite surface damage was material dependent. Premise surface was not altered by ultrasonic scaling significantly. Air-powder polishing with both powders produced a greater increase in surface roughness of composite resin and restorations margins than ultrasonic scaling. The Ra values after both types of air polishing for Herculite Ultra and Harmonize were approximately 1.5 and 2 times higher, respectively, than those after ultrasonic scaling (p < 0.05).
引用
收藏
页数:12
相关论文
共 59 条
[31]  
Jepsen S, 2018, J CLIN PERIODONTOL, V45, pS219, DOI [10.1111/jcpe.12951, 10.1002/JPER.17-0733]
[32]  
Khalefa M, 2013, J OROFAC ORTHOP, V74, P370, DOI 10.1007/s00056-013-0168-6
[33]  
Kimyai Soodabeh, 2016, J Dent Res Dent Clin Dent Prospects, V10, P23, DOI 10.15171/joddd.2016.004
[34]  
Kimyai Soodabeh, 2012, J Dent Res Dent Clin Dent Prospects, V6, P65
[35]   Efficacy of Polishing Kits on the Surface Roughness and Color Stability of Different Composite Resins [J].
Kocaagaoglu, H. ;
Aslan, T. ;
Gurbulak, A. ;
Albayrak, H. ;
Tasdemir, Z. ;
Gumus, H. .
NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2017, 20 (05) :557-565
[36]  
Kumari C Meena, 2016, J Conserv Dent, V19, P56, DOI 10.4103/0972-0707.173200
[37]   Effects of sonic and ultrasonic scaling on the surface roughness of tooth-colored restorative materials for cervical lesions [J].
Lai, Y. L. ;
Lin, Y. C. ;
Chang, C. S. ;
Lee, S. Y. .
OPERATIVE DENTISTRY, 2007, 32 (03) :273-278
[38]   Comparison of Root Surface Wear and Roughness Resulted from Different Ultrasonic Scalers and Polishing Devices Applied on Human Teeth: An In-Vitro Study [J].
Mahiroglu, Muhammed Bedir ;
Kahramanoglu, Erkut ;
Ay, Mustafa ;
Kuru, Leyla ;
Agrali, Omer Birkan .
HEALTHCARE, 2020, 8 (01)
[39]   Root surface alterations following manual and mechanical scaling: A comparative study [J].
Maritato, M. ;
Orazi, L. ;
Laurito, D. ;
Formisano, G. ;
Serra, E. ;
Lollobrigida, M. ;
Molinari, A. ;
De Biase, A. .
INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2018, 16 (04) :553-558
[40]  
Mittal Antush, 2014, J Indian Soc Periodontol, V18, P710, DOI 10.4103/0972-124X.147405