Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study

被引:182
作者
Reymus, Marcel [1 ]
Fabritius, Rosalie [2 ]
Kessler, Andreas [1 ]
Hickel, Reinhard [1 ]
Edelhoff, Daniel [2 ]
Stawarczyk, Bogna [2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Conservat Dent & Periodontol, Goethestr 70, D-80336 Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Goethestr 70, D-80336 Munich, Germany
关键词
3D printing; Fracture load; Build direction; Post-curing; Artificial aging; COMPUTER-AIDED-DESIGN; BEARING CAPACITY; MECHANICAL-PROPERTIES; DENTISTRY; ACCURACY;
D O I
10.1007/s00784-019-02952-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To investigate the impact of 3D print material, build direction, post-curing, and artificial aging on fracture load of fixed dental prostheses (FDPs). Materials and methods Three-unit FDPs were 3D-printed using experimental resin (EXP), NextDent C&B (CB), Freeprint temp (FT), and 3Delta temp (DT). In the first part, the impacts of build direction and artificial aging were tested. FDPs were manufactured with their long-axis positioned either occlusal, buccal, or distal to the printer's platform. Fracture load was measured after artificial aging (H2O: 21 days, 37 degrees C). In the second part, the impact of post-curing was tested. FDPs were post-cured using Labolight DUO, Otoflash G171, and LC-3DPrint Box. While the positive control group was milled from TelioCAD (TC), the negative control group was fabricated from a conventional interim material Luxatemp (LT). The measured initial fracture loads were compared with those after artificial aging. Each subgroup contained 15 specimens. Data were analyzed using Kolmogorov-Smirnov test, one-way ANOVA followed by Scheffe post hoc test, t test, Kruskal-Wallis test, and Mann-Whitney U test (p < 0.05). The univariate ANOVA with partial eta squared (eta(2)(P)) was used to analyze the impact of test parameters on fracture load. Results Specimens manufactured with their long-axis positioned distal to the printer's platform showed higher fracture load than occlusal ones (p = 0.049). The highest values were observed for CB, followed by DT (p < 0.001). EXP showed the lowest values, followed by FT (p < 0.001). After artificial aging, a decrease of fracture load for EXP (p < 0.001) and DT (p < 0.001) was observed. The highest impact on values was exerted by interactions between 3D print material and post-curing unit (eta(2)(P) = 0.233, p < 0.001), followed by the 3D print material (eta(2)(P) = 0.219, p < 0.001) and curing device (eta(2)(P) = 0.108, p < 0.001). Conclusions Build direction, post-curing, artificial aging, and material have an impact on the mechanical stability of printed FDPs.
引用
收藏
页码:701 / 710
页数:10
相关论文
共 24 条
[1]   Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations [J].
Alharbi, Nawal ;
Osman, Reham ;
Wismeijer, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) :760-767
[2]   The evolution of rapid prototyping in dentistry: a review [J].
Azari, Abbas ;
Nikzad, Sakineh .
RAPID PROTOTYPING JOURNAL, 2009, 15 (03) :216-225
[3]   Load-bearing capacity of handmade and computer-aided design-computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite [J].
Basaran, Emine Goncu ;
Ayna, Emrah ;
Vallittu, Pekka K. ;
Lassila, Lippo V. J. .
ACTA ODONTOLOGICA SCANDINAVICA, 2011, 69 (03) :144-150
[4]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[5]  
Duret F, 1991, Curr Opin Dent, V1, P150
[6]   Finite element and experimental analyses of polymer-based dental bridges reinforced by ceramic bars [J].
Fischer, H ;
Weber, M ;
Eck, M ;
Erdrich, A ;
Marx, R .
JOURNAL OF BIOMECHANICS, 2004, 37 (03) :289-294
[7]   Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques [J].
Hazeveld, Aletta ;
Slater, James J. R. Huddleston ;
Ren, Yijin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (01) :108-115
[8]   Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology [J].
Huang, Zhuoli ;
Zhang, Lu ;
Zhu, Jingwei ;
Zhang, Xiuyin .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06) :623-627
[9]   The influence of framework design on the load-bearing capacity of laboratory-made inlay-retained fibre-reinforced composite fixed dental prostheses [J].
Keulemans, Filip ;
Lassila, Lippo V. J. ;
Garoushi, Sufyan ;
Vallittu, Pekka K. ;
Kleverlaan, Cornelis J. ;
Feilzer, Albert J. .
JOURNAL OF BIOMECHANICS, 2009, 42 (07) :844-849
[10]   Guided Endodontics: a novel treatment approach for teeth with pulp canal calcification and apical pathology [J].
Krastl, Gabriel ;
Zehnder, Marc S. ;
Connert, Thomas ;
Weiger, Roland ;
Kuhl, Sebastian .
DENTAL TRAUMATOLOGY, 2016, 32 (03) :240-246