Investigation of the falling water flow with evaporation for the passive containment cooling system and its scaling-down criteria

被引:6
作者
Li, Cheng [1 ,2 ]
Li, Junming [1 ]
Li, Le [3 ]
机构
[1] Tsinghua Univ, Dept Thermal Engn, Key Lab Thermal Sci & Power Engn, Minist Educ, Beijing 100084, Peoples R China
[2] Gas Turbine Res Ctr, Beijing 100086, Peoples R China
[3] Tsinghua Univ, INET, Beijing 100084, Peoples R China
关键词
Falling film flow; Falling rivulet flow; Film rupture; AP1000; containment; LIQUID-FILM; SURFACE;
D O I
10.1007/s00231-017-2141-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
Falling water evaporation cooling could efficiently suppress the containment operation pressure during the nuclear accident, by continually removing the core decay heat to the atmospheric environment. In order to identify the process of large-scale falling water evaporation cooling, the water flow characteristics of falling film, film rupture and falling rivulet were deduced, on the basis of previous correlation studies. The influences of the contact angle, water temperature and water flow rates on water converge along the flow direction were then numerically obtained and results were compared with the data for AP1000 and CAP1400 nuclear power plants. By comparisons, it is concluded that the water coverage fraction of falling water could be enhanced by either reducing the surface contact angle or increasing the water temperature. The falling water flow with evaporation for AP1000 containment was then calculated and the feature of its water coverage fraction was analyzed. Finally, based on the phenomena identification of falling water flow for AP1000 containment evaporation cooling, the scaling-down is performed and the dimensionless criteria were obtained.
引用
收藏
页码:473 / 482
页数:10
相关论文
共 17 条
  • [11] Lu YH, 2016, SCI TECHNOL, V50, P835
  • [12] Qin L, 2012, BACHELOR DEGREE DALI, V6, P49
  • [13] Westinghouse AP1000 advanced passive plant
    Schulz, T. L.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2006, 236 (14-6) : 1547 - 1557
  • [14] Sha WT, 1997, NUCL ENG DES, V232, P197
  • [15] Spencer Dan R., 1999, 7 INT C NUCL ENG TOK
  • [16] Westinghouse Electric Company, 2008, WESTINGHOUSE TECHNIC, V3, P55
  • [17] Woodcock J, 1999, 7 INT C NUCL ENG TOK