Development of a luminol-based chemiluminescence flow-injection method for the determination of dichlorvos pesticide

被引:54
|
作者
Wang, JN
Zhang, C
Wang, HX
Yang, FZ
Zhang, XR [1 ]
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] Cent Stn Prairie, Qing Hai 810001, Peoples R China
关键词
chemiluminescence; flow inject analysis; dichlorvos pesticide; cyltrimethylammonium bromide;
D O I
10.1016/S0039-9140(01)00388-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast chemiluminescence (CL) flow-injection method based on the reaction of luminol with H2O2 in the presence of a cationic surfactant (cyltrimethylammonium bromide, CTMAB) has been described for the direct determination of dichlorvos pesticide (DDVP). Under the optimal conditions, the CL intensity was linear to the DDVP concentration in the range of 0.02-3.1 mug ml(-1) (r = 0.9998, n = 10). The relative standard deviation was 3.4% at 0.35 mug ml(-1) (n = 10), with a detection limit (3 sigma) of 0.008 mug ml(-1) DDVP. The possible reaction mechanism was also discussed. This method has been successfully applied to the determination of trace DDVP residue in vegetable sample and results have been compared with that of the UV method. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1185 / 1193
页数:9
相关论文
共 50 条
  • [1] Determination of metlhyl-parathion using luminol-based chemiluminescence flow injection method
    Rao, ZM
    Wang, JN
    Li, LD
    Zhang, XR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (04) : 373 - 377
  • [2] Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 81 - 86
  • [3] Flow-injection electrogenerated chemiluminescence determination of isoniazid using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICAL SCIENCES, 2001, 17 (09) : 1095 - 1099
  • [4] Flow-Injection Electrogenerated Chemiluminescence Determination of Isoniazid Using Luminol
    Xingwang Zheng
    Zhihui Guo
    Zhujun Zhang
    Analytical Sciences, 2001, 17 : 1095 - 1099
  • [5] Development of a New Flow-injection Chemiluminescence Method for the Determination of Sulfide
    Yang Yingchun
    Feng Yuanyuan
    Ye Zhixiang
    Yin Honglin
    Yang Huaijin
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [6] DETERMINATION OF SULFITE IN WINE THROUGH FLOW-INJECTION ANALYSIS BASED ON THE SUPPRESSION OF LUMINOL CHEMILUMINESCENCE
    HUANG, YL
    KIM, JM
    SCHMID, RD
    ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 317 - 323
  • [7] Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
    Wang, ZP
    Zhang, ZJ
    Zhang, XO
    Fu, ZF
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 1 - 7
  • [8] Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2008, 24 (08) : 979 - 983
  • [9] Photodegradation and Flow-Injection Determination of Simetryn Herbicide by Luminol Chemiluminescence Detection
    Amir Waseem
    Mohammad Yaqoob
    Abdul Nabi
    Analytical Sciences, 2008, 24 : 979 - 983
  • [10] Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2008, 23 (03) : 144 - 149