Composite stentless valve with graft extension for combined replacement of the aortic valve, root and ascending aorta

被引:10
作者
Byrne, JG
Mihaljevic, T
Lipson, WE
Smith, B
Fox, JA
Aranki, SF
机构
[1] Brigham & Womens Hosp, Div Cardiac Surg, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Div Cardiac Anesthesia, Boston, MA 02115 USA
关键词
freestyle; aortic valve replacement; ascending aortic aneurysm;
D O I
10.1016/S1010-7940(01)00799-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The composite mechanical valve conduit has been most commonly used for patients who require combined aortic valve, root,and ascending aorta replacement, but is limited, especially in the elderly, because of the need for long-term anticoagulation. We report the first consecutive series of patients in whom a composite stentless valve with graft extension, which does not require long-term anticoagulation, was performed. Methods: Between April 1998 and July 2000, eight patients with severe aortic root and ascending aortic pathology underwent a combined aortic valve, root, and ascending aorta replacement with a Freestyle((R)) stentless porcine valve with a Hemashield((R)) graft extension. Mean age was 74 (range 56-82), three were males. Concomitant procedures included coronary artery bypass graft (CABG) alone (n = 2), mitral valve replacement with atrial septal defect repair (n = 1) and CABG with septal myomectomy (n = 1). Results: Operative mortality was zero. Median aortic cross-clamp and cardiopulmonary bypass times were 150 and 203 min, respectively. Two patients returned to the operating room for bleeding. Median blood transfusions and hospital length of stay were 4 units and 11 days, respectively. Conclusions: The composite stentless valve with graft extension is a reasonable alternative to a mechanical valve conduit for patients who require a combined aortic valve, root, and ascending aorta replacement, in whom anticoagulation is not desirable or contra-indicated. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 11 条
[1]  
Akpinar B, 1999, TEX HEART I J, V26, P195
[2]  
Byrne J G, 1999, Heart Surg Forum, V2, P326
[3]  
Byrne JG, 1999, ANN THORAC SURG, V68, P1444
[4]   A 23-year experience with composite valve graft replacement of the aortic root [J].
Dossche, KM ;
Schepens, MAAM ;
Morshuis, WJ ;
de la Riviere, AB ;
Knaepen, PJ ;
Vermeulen, FEE .
ANNALS OF THORACIC SURGERY, 1999, 67 (04) :1070-1077
[5]  
Doty D B, 1999, Semin Thorac Cardiovasc Surg, V11, P35
[6]   Medtronic freestyle aortic root bioprosthesis: Implant techniques [J].
Doty, DB ;
Cafferty, A ;
Kon, ND ;
Huysmans, HA ;
Krause, AH ;
Westaby, S .
JOURNAL OF CARDIAC SURGERY, 1998, 13 (05) :369-375
[7]   16-YEAR EXPERIENCE WITH AORTIC ROOT REPLACEMENT - RESULTS OF 172 OPERATIONS [J].
KOUCHOUKOS, NT ;
WAREING, TH ;
MURPHY, SF ;
PERRILLO, JB .
ANNALS OF SURGERY, 1991, 214 (03) :308-320
[8]   REOPERATIVE AORTIC-VALVE OPERATION AFTER HOMOGRAFT ROOT REPLACEMENT - SURGICAL OPTIONS AND RESULTS [J].
SUNDT, TM ;
RASMI, N ;
WONG, K ;
RADLEYSMITH, R ;
KHAGHANI, A ;
YACOUB, MH .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S95-S100
[9]   Replacement of the ascending aorta and aortic valve with a valved stentless composite graft [J].
Urbanski, PP .
ANNALS OF THORACIC SURGERY, 1999, 67 (05) :1501-1502
[10]   Replacement of the aortic valve and ascending aorta with a valved stentless composite graft: Technical considerations and early clinical results [J].
Urbanski, PP ;
Hacker, RW .
ANNALS OF THORACIC SURGERY, 2000, 70 (01) :17-20