Determination of the slow crack growth susceptibility coefficient of dental ceramics using different methods

被引:10
作者
Gonzaga, Carla Castiglia [1 ,2 ]
Cesar, Paulo Francisco [1 ]
Miranda, Walter Gomes, Jr. [1 ]
Yoshimura, Humberto Naoyuki [3 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biochem, Sao Paulo, Brazil
[2] Positivo Univ, Sch Dent, Curitiba, Parana, Brazil
[3] Fed Univ ABC, Ctr Engn Modeling & Appl Social Sci, Santo Andre, Brazil
基金
巴西圣保罗研究基金会;
关键词
slow crack growth; subcritical crack growth; stress corrosion; dental ceramics; constant stress-rate test; constant stress test; indentation fracture test; INDENTATION FRACTURE-TOUGHNESS; STATIC FATIGUE; ALUMINA-CERAMICS; DYNAMIC FATIGUE; LIFETIME PREDICTION; FLEXURAL STRENGTH; STRESS-CORROSION; SILICATE GLASS; PORCELAINS; RESTORATIONS;
D O I
10.1002/jbm.b.31892
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study compared three methods for the determination of the slow crack growth susceptibility coefficient (n) of two veneering ceramics (VM7 and d.Sign), two glass-ceramics (Empress and Empress 2) and a glass-infiltrated alumina composite (In-Ceram Alumina). Discs (n 10) were prepared according to manufacturers' recommendations and polished. The constant stress-rate test was performed at five constant stress rates to calculate n(d). For the indentation fracture test to determine n(IF), Vickers indentations were performed and the crack lengths were measured under an optical microscope. For the constant stress test (performed only for d.Sign for the determination of ns) four constant stresses were applied and held constant until the specimens' fracture and the time to failure was recorded. All tests were performed in artificial saliva at 37 degrees C. The n(d) values were 17.2 for Empress 2, followed by d.Sign (20.5), VM7 (26.5), Empress (30.2), and In-Ceram Alumina (31.1). In-Ceram Alumina and Empress 2 showed the highest n(IF) values, 66.0 and 40.2, respectively. The n(IF) values determined for Empress (25.2), d.Sign (25.6), and VM7 (20.1) were similar. The ns value determined for d.Sign was 31.4. It can be concluded that the n values determined for the dental ceramics evaluated were significantly influenced by the test method used. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 99B: 247-257, 2011.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 58 条
[1]  
Ali S M, 1993, Dent Mater J, V12, P45
[2]  
[Anonymous], 1920, The phenomena of Rupture and Flow in Solids
[3]   A CRITICAL-EVALUATION OF INDENTATION TECHNIQUES FOR MEASURING FRACTURE-TOUGHNESS .1. DIRECT CRACK MEASUREMENTS [J].
ANSTIS, GR ;
CHANTIKUL, P ;
LAWN, BR ;
MARSHALL, DB .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1981, 64 (09) :533-538
[4]   INFLUENCE OF TEMPERING AND CONTRACTION MISMATCH ON CRACK DEVELOPMENT IN CERAMIC SURFACES [J].
ANUSAVICE, KJ ;
DEHOFF, PH ;
HOJJATIE, B ;
GRAY, A .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (07) :1182-1187
[5]  
*ASTM, 2001, ASTMC1368
[6]  
*ASTM, 1996, ASTMF39478
[7]  
Barsoum M.W., 1997, Fundamentals of Ceramics, V2nd ed.
[8]   Flexural Strength of Glass-Infiltrated Zirconia/Alumina-Based Ceramics and Feldspathic Veneering Porcelains [J].
Bottino, Marco Antonio ;
Salazar-Marocho, Susana M. ;
Leite, Fabiola P. P. ;
Vasquez, Vanessa C. ;
Valandro, Luiz Felipe .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05) :417-420
[9]   Influence of leucite content on slow crack growth of dental porcelains [J].
Cesar, Paulo R. ;
Soki, Fabiana N. ;
Yoshimura, Humberto N. ;
Gonzaga, Carla C. ;
Styopkin, Victor .
DENTAL MATERIALS, 2008, 24 (08) :1114-1122
[10]   Exponential slow crack growth of glass and advanced ceramics - dynamic fatigue [J].
Choi, SR ;
Nemeth, NN ;
Gyekenyesi, JP .
FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2005, 28 (05) :489-497