Determination of loratadine in human plasma by liquid chromatography electrospray ionization ion-trap tandem mass spectrometry

被引:23
作者
Salem, II [1 ]
Idrees, J [1 ]
Al Tamimi, JI [1 ]
机构
[1] ACDIMA Ctr Bioequivalence & Pharmaceut Studies, Amman 11190, Jordan
关键词
loratadine; HPLC; MS/MS; human plasma; method validation;
D O I
10.1016/j.japna.2003.07.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and specific liquid chromatography electrospray ionization ion-trap mass spectrometry (LC-ESI-IT-MS/MS) method has been developed and validated for the identification and quantitation of loratadine in human plasma. After the addition of the internal standard (IS), plasma samples were extracted using isooctane:isoamyl alcohol mixture. The compounds were separated on a prepacked Zorbax phenyl column using a mixture of acetonitrile, 0.20% formic acid as mobile phase. A Finnigan LCQ(DUO) ion-trap mass spectrometer connected to a Waters Alliance high performance liquid chromatography (HPLC) was used to develop and validate the method. The results were within the accepted criteria as stated in the FDA bioanalytical method validation guidance. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.10-10.0 ng/ml with a coefficient of determination (r(2)) of 0.9998. Accuracy for loratadine ranged from 105.00 to 109.50% at low, mid and high levels. The intra-day precision was better than 10.86%. The lower limit of quantitation (LLOQ) was identifiable and reproducible at 0.10 ng/ml with a precision of 9.84%. The proposed method enables the unambiguous identification and quantitation of loratadine for pharmacokinetic, bioavailability or bioequivalence studies. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 151
页数:11
相关论文
共 11 条
[1]  
[Anonymous], 2001, Guidance for Industry-bioanalytical method validation
[2]  
[Anonymous], 2003, GUIDANCE IND BIOAVAI
[3]   PHARMACOKINETICS AND DOSE PROPORTIONALITY OF LORATADINE [J].
HILBERT, J ;
RADWANSKI, E ;
WEGLEIN, R ;
LUC, V ;
PERENTESIS, G ;
SYMCHOWICZ, S ;
ZAMPAGLIONE, N .
JOURNAL OF CLINICAL PHARMACOLOGY, 1987, 27 (09) :694-698
[4]   Determination of loratadine in human plasma by high-performance liquid chromatographic method with ultraviolet detection [J].
Kunicki, PK .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :331-335
[5]   DETERMINATION OF LORATADINE AND PHENIRAMINE FROM HUMAN SERUM BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MARTENS, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 673 (02) :183-188
[6]  
Parfitt K, 1999, COMPLETE DRUG REFERE, P413
[7]   Sensitive liquid chromatography-tandem mass spectrometry method for the determination of loratadine and its major active metabolite descarboethoxyloratadine in human plasma [J].
Sutherland, FCW ;
de Jager, AD ;
Badenhorst, D ;
Scanes, T ;
Hundt, HKL ;
Swart, KJ ;
Hundt, AF .
JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) :37-43
[8]   Simultaneous development of six LC-MS-MS methods for the determination of multiple analytes in human plasma [J].
Weng, ND ;
Bu, HZ ;
Chen, YL ;
Shou, WZ ;
Jiang, XY ;
Halls, TDJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (06) :1115-1126
[9]   Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays [J].
Yang, LY ;
Amad, M ;
Winnik, WM ;
Schoen, AE ;
Schweingruber, H ;
Mylchreest, I ;
Rudewicz, PJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (21) :2060-2066
[10]   Evaluation of a four-channel multiplexed electrospray triple quadrupole mass spectrometer for the simultaneous validation of LC/MS/MS methods in four different preclinical matrixes [J].
Yang, LY ;
Mann, TD ;
Little, D ;
Wu, N ;
Clement, RP ;
Rudewicz, PJ .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1740-1747