Experimental investigation of the influence of freestream turbulence on an anti-vortex film cooling hole

被引:23
作者
Hayes, Stephen A. [1 ]
Nix, Andrew C. [1 ]
Nestor, Christopher M. [1 ]
Billups, David T. [1 ]
Haught, Shane M. [1 ]
机构
[1] West Virginia Univ, Dept Mech & Aerosp Engn, 271 ESB Annex, Morgantown, WV 26506 USA
关键词
Gas turbine; Film cooling; Heat transfer; Infrared thermography; Anti-vortex hole; FLOW;
D O I
10.1016/j.expthermflusci.2016.10.025
中图分类号
O414.1 [热力学];
学科分类号
摘要
Film cooling is used in gas turbines to thermally protect combustor and turbine hot section components by creating a layer of relatively cooler air to insulate the components from the hot freestream gases. This relatively cooler air is taken from upstream in the compressor section at a loss to the engine efficiency and therefore must be used as effectively as possible. A novel anti-vortex hole (AVH) geometry has been investigated experimentally through a transient infrared thermography technique to study the film cooling effectiveness and heat transfer coefficient by varying blowing ratio and freestream turbulence intensity. The AVH geometry is designed with two secondary holes stemming from a main cooling hole that attempts to diffuse the coolant jet and mitigate the vorticity produced by conventional straight holes. The AVH geometry data collected showed improved cooling performance at low freestream turbulence intensities compared to conventional straight holes. Three turbulence intensities of 1, 7.5, and 11.7% were investigated for the AVH geometry at blowing ratios of 0.5, 1.0, 1.5, and 2.0 for a total of twelve different conditions. Results showed that higher freestream turbulence conditions were beneficial to the performance of the AVH. Increasing the blowing ratio at all turbulence levels also improved film cooling effectiveness, both span-averaged and on the centerline. The highest performing case was at a turbulence intensity of 7.5% and a blowing ratio of 2.0. The 11.7% cases outperformed the 1% cases, but it appears that at the 11.7% cases the higher freestream turbulence reduces the performance of the secondary holes compared to the 7.5% case. Increasing the blowing ratio and turbulence intensity will result in a higher heat transfer coefficient, which must be taken into account for future designs and overall reduction of heat load. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:314 / 326
页数:13
相关论文
共 22 条
[1]   The effect of high free-stream turbulence on film cooling effectiveness [J].
Bons, JP ;
MacArthur, CD ;
Rivir, RB .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1996, 118 (04) :814-825
[2]  
Bradshaw P., 2014, WIND TUNNEL DESIGN
[3]   A review of shaped hole turbine film-cooling technology [J].
Bunker, RS .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2005, 127 (04) :441-453
[4]  
Dhungel A, 2007, THESIS
[5]  
Dhungel A., GT200727419 ASME
[6]   A transient infrared thermography method for simultaneous film cooling effectiveness and heat transfer coefficient measurements from a single test [J].
Ekkad, SV ;
Ou, SC ;
Rivir, RB .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2004, 126 (04) :597-603
[7]  
Haven B.A., 97GT451997 ASME
[8]  
Heidmann J.D., FT200727528 ASME
[9]  
Heidmann J.D., GT200850845 ASME
[10]  
Hunley B.K., GT201022077 ASME