Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

被引:22
作者
Fang, Yuan [1 ,2 ]
Badal, Andreu [1 ]
Allec, Nicholas [2 ]
Karim, Karim S. [2 ]
Badano, Aldo [1 ]
机构
[1] US FDA, Div Imaging & Appl Math, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
[2] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Swank factor; semiconductor detector; Monte Carlo; amorphous selenium; AMORPHOUS SELENIUM; PHOTOGENERATION; RECOMBINATION; MAMMOGRAPHY; SIMULATION;
D O I
10.1118/1.3669486
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor. Swank factor. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3669486]
引用
收藏
页码:308 / 319
页数:12
相关论文
共 34 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
Babiker S., 1995, SOLID STATE ELECT, V39, P629
[3]   penMesh-Monte Carlo Radiation Transport Simulation in a Triangle Mesh Geometry [J].
Badal, Andreu ;
Kyprianou, Iacovos ;
Banh, Diem Phuc ;
Badano, Aldo ;
Sempau, Josep .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (12) :1894-1901
[4]   MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems [J].
Badano, A ;
Sempau, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) :1545-1561
[5]   Anisotropic imaging performance in indirect x-ray imaging detectors [J].
Badano, Aldo ;
Kyprianou, Iacovos S. ;
Sempau, Josep .
MEDICAL PHYSICS, 2006, 33 (08) :2698-2713
[6]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[7]  
BARRETT HH, 2004, FDN IMAGE SCI, P748
[8]  
BARTCZAK WM, 1991, RADIAT PHYS CHEM, V37, P401
[9]   Digital breast tomosynthesis using an amorphous selenium flat panel detector [J].
Bissonnette, M ;
Hansroul, M ;
Masson, E ;
Savard, S ;
Cadieux, S ;
Warmoes, P ;
Gravel, D ;
Agopyan, J ;
Polischuk, B ;
Haerer, W ;
Mertelmeier, T ;
Lo, JY ;
Chen, Y ;
Dobbins, JT ;
Jesneck, JL ;
Singh, S .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :529-540
[10]   Measurement of x-ray photogeneration in amorphous selenium [J].
Blevis, IM ;
Hunt, DC ;
Rowlands, JA .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (11) :7958-7963