Insufficient Acetabular Version Increases Blood Metal Ion Levels after Metal-on-metal Hip Resurfacing

被引:59
作者
Hart, Alister J. [1 ]
Skinner, John A. [2 ]
Henckel, Johann [1 ]
Sampson, Barry [3 ,4 ]
Gordon, Fabiana [5 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Orthopaed Surg, London SW7 2AZ, England
[2] UCL, Dept Orthopaed Surg, Royal Natl Orthopaed Hosp, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Clin Chem, London SW7 2AZ, England
[4] Imperial Coll Healthcare NHS Trust, London, England
[5] Univ London Imperial Coll Sci Technol & Med, Stat Advisory Serv, London SW7 2AZ, England
关键词
30-YEAR FOLLOW-UP; SURFACE REPLACEMENT; ACTIVE PATIENTS; ARTHROPLASTY; COMPONENT; COBALT; WEAR; ORIENTATION; CHROMIUM; CUP;
D O I
10.1007/s11999-011-1930-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Many factors affect the blood metal ion levels after metal-on-metal (MOM) hip arthroplasty. The main surgically adjustable variable is the amount of coverage of the head provided by the cup which is a function of the inclination and version angles. However, most studies have used plain radiographs which have questionable precision and accuracy, particularly for version and large diameter metal heads; further, these studies do not simultaneously assess version and inclination. Thus the relationship between version and blood metal ions levels has not been resolved. Questions/purposes We determined whether cup inclination and version influence blood metal ion levels while adjusting for age at assessment, gender, body mass index, horizontal femoral offset, head size, manufacturer hip type, and Oxford hip score. Patients and Methods We prospectively followed 100 individuals (51 females, 49 males) with unilateral MOM hip resurfacing who underwent clinical assessment, CT scanning, and blood metal ion measurement. Multiple regression analysis was used to determine which variables were predictors of blood metal ion levels and to model the effect of these variables. Results Only cup inclination, version angles, and gender influenced blood cobalt or chromium levels. Cobalt and chromium levels positively correlated with inclination angle and negatively correlated with version angle. The effect of changes in version angle was less than for inclination angle. Based on our observations, we developed a formula to predict the effect of these parameters on metal ion levels. Conclusions Our data suggest insufficient cup version can cause high blood metal ions after MOM hip arthroplasty. We were unable to show that excessive version caused high levels. Level of Evidence Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:2590 / 2597
页数:8
相关论文
共 42 条
  • [11] Revision of metal-on-metal resurfacing arthroplasty of the hip - The influence of malpositioning of the components
    De Haan, R.
    Campbell, P. A.
    Su, E. P.
    De Smet, K. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (09): : 1158 - 1163
  • [12] De Haan R, 2007, J BONE JOINT SURG BR, V89B, P538, DOI 10.1302/0301-620X.89B4
  • [13] DESY NM, 2010, CLIN ORTHOP REL 1023
  • [14] A hip joint simulator study of the performance of metal-on-metal joints - Part II: Design
    Dowson, D
    Hardaker, C
    Flett, M
    Isaac, GH
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08) : 124 - 130
  • [15] Metal ion levels after metal-on-metal proximal femoral replacements - A 30-year follow-up
    Dunstan, E
    Sanghrajka, AP
    Tilley, S
    Unwin, P
    Blunn, G
    Cannon, SR
    Briggs, TWR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05): : 628 - 631
  • [16] GROVER M, 2007, J BONE JOINT SURG BR, V89, P586
  • [17] Grübl A, 2006, J BONE JOINT SURG BR, V88B, P1003, DOI 10.1302/0301-620X.88B8
  • [18] Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia
    Hart, A. J.
    Skinner, J. A.
    Winship, P.
    Faria, N.
    Kulinskaya, E.
    Webster, D.
    Muirhead-Allwood, S.
    Aldam, C. H.
    Anwar, H.
    Powell, J. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 835 - 842
  • [19] The painful metal-on-metal hip resurfacing
    Hart, A. J.
    Sabah, S.
    Henckel, J.
    Lewis, A.
    Cobb, J.
    Sampson, B.
    Mitchell, A.
    Skinner, J. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 738 - 744
  • [20] Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing
    Hart, A. J.
    Buddhdev, P.
    Winship, P.
    Faria, N.
    Powell, J. J.
    Skinner, J. A.
    [J]. HIP INTERNATIONAL, 2008, 18 (03) : 212 - 219