Insufficient Acetabular Version Increases Blood Metal Ion Levels after Metal-on-metal Hip Resurfacing

被引:59
作者
Hart, Alister J. [1 ]
Skinner, John A. [2 ]
Henckel, Johann [1 ]
Sampson, Barry [3 ,4 ]
Gordon, Fabiana [5 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Orthopaed Surg, London SW7 2AZ, England
[2] UCL, Dept Orthopaed Surg, Royal Natl Orthopaed Hosp, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Clin Chem, London SW7 2AZ, England
[4] Imperial Coll Healthcare NHS Trust, London, England
[5] Univ London Imperial Coll Sci Technol & Med, Stat Advisory Serv, London SW7 2AZ, England
关键词
30-YEAR FOLLOW-UP; SURFACE REPLACEMENT; ACTIVE PATIENTS; ARTHROPLASTY; COMPONENT; COBALT; WEAR; ORIENTATION; CHROMIUM; CUP;
D O I
10.1007/s11999-011-1930-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Many factors affect the blood metal ion levels after metal-on-metal (MOM) hip arthroplasty. The main surgically adjustable variable is the amount of coverage of the head provided by the cup which is a function of the inclination and version angles. However, most studies have used plain radiographs which have questionable precision and accuracy, particularly for version and large diameter metal heads; further, these studies do not simultaneously assess version and inclination. Thus the relationship between version and blood metal ions levels has not been resolved. Questions/purposes We determined whether cup inclination and version influence blood metal ion levels while adjusting for age at assessment, gender, body mass index, horizontal femoral offset, head size, manufacturer hip type, and Oxford hip score. Patients and Methods We prospectively followed 100 individuals (51 females, 49 males) with unilateral MOM hip resurfacing who underwent clinical assessment, CT scanning, and blood metal ion measurement. Multiple regression analysis was used to determine which variables were predictors of blood metal ion levels and to model the effect of these variables. Results Only cup inclination, version angles, and gender influenced blood cobalt or chromium levels. Cobalt and chromium levels positively correlated with inclination angle and negatively correlated with version angle. The effect of changes in version angle was less than for inclination angle. Based on our observations, we developed a formula to predict the effect of these parameters on metal ion levels. Conclusions Our data suggest insufficient cup version can cause high blood metal ions after MOM hip arthroplasty. We were unable to show that excessive version caused high levels. Level of Evidence Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:2590 / 2597
页数:8
相关论文
共 42 条
  • [1] Influence of cup orientation on the wear performance of metal-on-metal hip replacements
    Angadji, A.
    Royle, M.
    Collins, S. N.
    Shelton, J. C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H4) : 449 - 457
  • [2] Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses
    Antoniou, John
    Zukor, David J.
    Mwale, Fackson
    Minarik, William
    Petit, Alain
    Huk, Olga L.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 142 - 148
  • [3] How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
    Back, DL
    Young, AA
    Shimmin, AJ
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 177 - 181
  • [4] Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity
    Bowsher, JG
    Hussain, A
    Williams, PA
    Shelton, JC
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 279 - 287
  • [5] The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United States
    Bozic, Kevin J.
    Kurtz, Steven
    Lau, Edmund
    Ong, Kevin
    Chiu, Vanessa
    Vail, Thomas P.
    Rubash, Harry E.
    Berry, Daniel J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) : 1614 - 1620
  • [6] Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty
    Clarke, MT
    Lee, PTH
    Arora, A
    Villar, RN
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06): : 913 - 917
  • [7] Three-dimensional CT analysis to determine acetabular retroversion and the implications for the management of femoro-acetabular impingement
    Dandachli, W.
    Islam, S. Ul
    Liu, M.
    Richards, R.
    Hall-Craggs, M.
    Witt, J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (08): : 1031 - 1036
  • [8] Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty - Four-year results of a prospective longitudinal study
    Daniel, J.
    Ziaee, H.
    Pradhan, C.
    Pynsent, P. B.
    McMinn, D. J. W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02): : 169 - 173
  • [9] Questionnaire on the perceptions of patients about total hip replacement
    Dawson, J
    Fitzpatrick, R
    Carr, A
    Murray, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02): : 185 - 190
  • [10] Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
    De Haan, R.
    Pattyn, C.
    Gill, H. S.
    Murray, D. W.
    Campbell, P. A.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10): : 1291 - 1297