Short-Term Test-Retest Reliability of Electrically Evoked Cortical Auditory Potentials in Adult Cochlear Implant Recipients

被引:3
作者
Pike, Meghan [1 ]
Biagio-de Jager, Leigh [1 ]
le Roux, Talita [1 ]
Hofmeyr, Louis M. [1 ]
机构
[1] Univ Pretoria, Dept Speech Language Pathol & Audiol, Pretoria, South Africa
关键词
cochlear implant; test-retest reliability; cortical auditory evoked potentials; late latency auditory evoked potentials; electrical evoked responses; aided; INTRACLASS CORRELATION-COEFFICIENTS; SPEECH-PERCEPTION; REPLICABILITY; THRESHOLD; ATTENTION; RESPONSES; CHILDREN; AUDITION; P300; DEAF;
D O I
10.3389/fneur.2020.00305
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Late latency auditory evoked potentials (LLAEPs) provide objective evidence of an individual's central auditory processing abilities. Electrically evoked cortical auditory evoked potentials (eCAEPs) are a type of LLAEP that provides an objective measure of aided speech perception and auditory processing abilities in cochlear implant (CI) recipients. Aim: To determine the short-term test-retest reliability of eCAEPs in adult CI recipients. Design: An explorative, within-subject repeated measures research design was employed. Study Sample: The study sample included 12 post-lingually deafened, unilaterally implanted adult CI recipients with at least 9 months of CI experience. Method: eCAEPs representing basal, medial and apical cochlear regions were recorded in the implanted ears of each participant. Measurements were repeated 7 days after the initial assessment. Results: No significant differences between either median latencies or amplitudes at test and retest sessions (p > 0.05) were found when results for apical, medial and basal electrodes were averaged together. Mean intraclass correlation coefficient (ICC) scores averaged across basal, medial and apical cochlear stimulus regions indicated that both consistency and agreement were statistically significant and ranged from moderate to good (ICC = 0.58-0.86, p < 0.05). ICC confidence intervals did demonstrate considerable individual variability in both latency and amplitudes. Conclusion: eCAEP latencies and amplitudes demonstrated moderate to good short-term test-retest reliability. However, confidence intervals indicated individual variability in measurement consistency which is likely linked to attention and listening effort required from the CI recipients.
引用
收藏
页数:8
相关论文
共 46 条
[1]  
Angel R, 2016, THESIS
[2]  
[Anonymous], 2015, EHANDBOOK AUDITORY E
[3]  
[Anonymous], 2015, MULTIPLE REGRESSION
[4]  
Arfin WN, 2017, SAMPLE SIZE CALCULAT
[5]  
Billings Curtis J., 2013, Seminars in Hearing, V34, P257, DOI 10.1055/s-0033-1356638
[6]  
British Society of Audiology, 2016, BSA CORT ERA GUID CO
[7]   The electrically evoked auditory change complex: Preliminary results from Nucleus cochlear implant users [J].
Brown, Carolyn J. ;
Etler, Christine ;
He, Shuman ;
O'Brien, Sara ;
Erenberg, Sheryl ;
Kim, Jae-Ryong ;
Dhuldhoya, Aayesha N. ;
Abbas, Paul J. .
EAR AND HEARING, 2008, 29 (05) :704-717
[8]   A review of the evidence for P2 being an independent component process: age, sleep and modality [J].
Crowley, KE ;
Colrain, IM .
CLINICAL NEUROPHYSIOLOGY, 2004, 115 (04) :732-744
[9]  
Czarniak L.J., 2011, Independent Studies and Capstones
[10]   Classroom performance of children with cochlear implants in mainstream education [J].
Damen, Godelieve W. J. A. ;
van den Oever-Goltstein, Marilene H. L. ;
Langereis, Margreet C. ;
Chute, Patricia M. ;
Mylanus, Emmanuel A. M. .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2006, 115 (07) :542-552