Towards real-time magnetomotive ultrasound imaging

被引:0
|
作者
Evertsson, Maria [1 ]
Ramalli, Alessandro [2 ]
Pavan, Theo Z. [3 ]
Cabrelli, Luciana C. [3 ]
Andersson, Roger [4 ]
Cinthio, Magnus [5 ]
Tortoli, Piero [2 ]
Jansson, Tomas [1 ,4 ]
机构
[1] Lund Univ, Dept Clin Sci Lund, Biomed Engn, Lund, Sweden
[2] Univ Florence, Dept Informat Engn, Florence, Italy
[3] Univ Sao Paulo, Dept Phys, Ribeirao Preto, SP, Brazil
[4] Skane Univ Hosp, Med Serv, Lund, Sweden
[5] Lund Univ, Fac Engn LTH, Biomed Engn, Lund, Sweden
基金
瑞典研究理事会;
关键词
Magnetomotive ultrasound imaging; ULA-OP; Contrast agents; MOTIVE ULTRASOUND; NANOPARTICLES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Enabling detection of nanoparticles with ultrasound can open new application avenues for the ultrasound technique. Magnetomotive ultrasound (MMUS) is a technique under development which indirectly visualizes magnetic nanoparticles. In MMUS, an external time-varying magnetic field acts to displace the nanoparticles, and thus their closest surrounding. This induced displacement is subsequently detected and the nanoparticle location may then be revealed. The MMUS technique has shown to be promising in both phantom and animal studies but limited efforts have been made on optimizing the technique for clinical applications in the sense of providing real-time bedside imaging. In this work, the previously proposed MMUS algorithm is automated and implemented online on the ULA-OP scanner. To evaluate the online implementation, a phantom made of styrene-ethylene/butylene-styrene and mineral oil with a 2 % magnetic ferrite particle inclusion was used. MMUS displacement was calculated in the entire image area, 192x230 pixels, and in a sub-region of 130x90 pixels, covering the inclusion. It was found that the automated online implementation computes one full MMUS image in 2.8 seconds and the sub-region in 1.17 seconds, which should be compared to 1-2 minutes in post processing mode. An immediate on-screen change in the magnetomotive displacement could be observed as the applied magnetic field was altered.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Real-Time Magnetomotive Ultrasound Imaging Using a Recursive Estimator
    Kranemann, Tim C.
    Ersepke, Thomas
    Schmitz, Georg
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [2] Real-time ultrasound phase imaging
    Bilodeau, Maxime
    Amyot, Felix-Antoine
    Masson, Patrice
    Quaegebeur, Nicolas
    ULTRASONICS, 2023, 134
  • [3] REAL-TIME ULTRASOUND IMAGING OF THE BRAIN
    DOHRMANN, GJ
    RUBIN, JM
    ANNALS OF NEUROLOGY, 1982, 12 (01) : 90 - 90
  • [4] REAL-TIME ULTRASOUND IMAGING OF MUSCLES
    HECKMATT, JZ
    PIER, N
    DUBOWITZ, V
    MUSCLE & NERVE, 1988, 11 (01) : 56 - 65
  • [5] Real-time ultrasound imaging simulation
    Aiger, D
    Cohen-Or, D
    REAL-TIME IMAGING, 1998, 4 (04) : 263 - 274
  • [6] DYNAMIC IMAGING OF THE STOMACH BY REAL-TIME ULTRASOUND
    HOLT, S
    HEADING, RC
    MCDICKEN, WN
    ANDERSON, T
    SUMERLING, MD
    GUT, 1979, 20 (10) : A935 - A935
  • [7] REAL-TIME INTRAVASCULAR ULTRASOUND IMAGING IN HUMANS
    PANDIAN, NG
    KREIS, A
    WEINTRAUB, A
    MOTARJEME, A
    DESNOYERS, M
    ISNER, JM
    KONSTAM, M
    SALEM, DN
    MILLEN, V
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (20): : 1392 - 1396
  • [8] Real-time in vivo photoacoustic and ultrasound imaging
    Kolkman, Roy G. M.
    Brands, Peter J.
    Steenbergen, Wiendelt
    van Leeuwen, Ton G.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (05)
  • [9] Real-Time Intravascular Ultrasound and Photoacoustic Imaging
    VanderLaan, Donald
    Karpiouk, Andrei B.
    Yeager, Doug
    Emelianov, Stanislav
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (01) : 141 - 149
  • [10] Towards real-time hyperspectral imaging in neurosurgery
    Roddan, Alfie
    Yu, Ziyan
    Leiloglou, Maria
    Chalau, Vadzim
    Anichini, Giulio
    Giannarou, Stamatia
    Elson, Daniel
    CLINICAL BIOPHOTONICS III, 2024, 13009