Modeling of high pressure steam condensation in inclined horizontal tubes of PAFS in APR

被引:6
作者
Yun, Bong Yo [1 ,2 ]
No, Hee Cheon [1 ]
Shin, Chang Wook [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon, South Korea
[2] KHNP Cent Res Inst, 70,Yuseong Daero 1313beon Gil, Daejeon, South Korea
关键词
PAFS; inclined horizontal tube; high pressure steam condensation; AUXILIARY FEEDWATER SYSTEM; HEAT-TRANSFER; FILM CONDENSATION; CAPABILITY; EXCHANGER;
D O I
10.1080/00223131.2015.1110505
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A Single-tube COndensation exPeriment (SCOP) was performed at Korea Advanced Institute of Science and Technology (KAIST) to simulate the condensation phenomena of Passive Auxiliary Feedwater System (PAFS), which is introduced in Advanced Power Reactor Plus. SCOP tests were conducted for two pipes of different diameters [22.6 and 44.8 mm inside diameter] with 8.2 m length and 2.5-4 degrees of the inclined angles of the upper and lower section of each tube. The experiment were performed at 1.5-6.5 MPa of steam pressure and 0.12-0.45 kg/s of steam flow. Based on the Kim and No correlation (KAIST, 2000), we developed a new turbulent-condensation correlation for the turbulent region of the liquid film in the inclined tube. We introduced the factors to account for the different inclined angle effect, different diameter effect. The Nusselt correlation is adopted for condensation near the tube inlet where the laminar region of the liquid film is dominant due to the small amount of condensed water. The present correlation was compared with the Shah and RELAP5 condensation model using the SCOP data. The root mean square errors of the present correlation, Shah model, and RELAP5 model are 17.41%, 57.88%, and 43.07%, respectively: the present correlation can predict well the condensation characteristics in comparison with other correlations in PAFS.
引用
收藏
页码:1353 / 1365
页数:13
相关论文
共 25 条
[1]  
[Anonymous], ONE DIMENSIONAL 2 PH
[2]  
[Anonymous], HEAT TRANS C
[3]  
[Anonymous], 95 ACRC U ILL
[4]  
[Anonymous], TR141 ACRC U ILL
[5]  
[Anonymous], THESIS
[6]  
[Anonymous], TR57 U ILL AIR COND
[7]  
[Anonymous], CHEM ENG FUNDAMENTAL
[8]   Design of condensation heat exchanger for the PAFS (Passive Auxiliary Feedwater System) of APR plus (Advanced Power Reactor Plus) [J].
Bae, Byoung-Uhn ;
Yun, Byong-Jo ;
Kim, Seok ;
Kang, Kyoung Ho .
ANNALS OF NUCLEAR ENERGY, 2012, 46 :134-143
[9]   Condensation of halogenated refrigerants inside smooth tubes [J].
Cavallini, A ;
Censi, G ;
Del Col, D ;
Doretti, L ;
Longo, GA ;
Rossetto, L .
HVAC&R RESEARCH, 2002, 8 (04) :429-451
[10]   Condensation in horizontal smooth tubes: A new heat transfer model for heat exchanger design [J].
Cavallini, Alberto ;
Del Col, Davide ;
Doretti, Luca ;
Matkovic, Marko ;
Rossetto, Luisa ;
Zilio, Claudio ;
Censi, Giuseppe .
HEAT TRANSFER ENGINEERING, 2006, 27 (08) :31-38