Displacement vector measurement using instantaneous ultrasound signal phase - Multidimensional autocorrelation and Doppler methods

被引:55
作者
Sumi, Chikayoshi [1 ]
机构
[1] Sophia Univ, Fac Sci & Technol, Dept Elect & Elect Engn, Chiyoda Ku, Tokyo 1028554, Japan
关键词
D O I
10.1109/TUFFC.2008.614
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Two new methods of measuring a multidimensional displacement vector using an instantaneous ultrasound signal phase are described, i.e., the multidimensional autocorrelation method (MAM) and multidimensional Doppler method (MDM). A high measurement accuracy is achieved by combining either method with the lateral Gaussian envelope cosine modulation method (LGECMM) or multidirectional synthetic aperture method (MDSAM). Measurement accuracy is evaluated using simulated noisy echo data. Both methods yield accurate measurements comparable to that of our previously developed cross-spectrum phase gradient method (MCSPGM); however, they require less computational time (the order, MDM < MAM approximate to MCSPGM) and would provide real-time measurements. Moreover, comparisons of LGECMM and MDSAM performed by geometrical evaluations clarifies that LGECMM has potentials to yield more accurate measurements with less computational time. Both MAM and MDM can be applied to the measurement of tissue strain, blood flow, sonar data, and other target motions.
引用
收藏
页码:24 / 43
页数:20
相关论文
共 55 条
[1]   Multi-dimensional velocity estimation with ultrasound using spatial quadrature [J].
Anderson, ME .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :852-861
[2]  
BARKER DW, 1970, IEEE T SON ULTRASON, V17, P170
[3]  
Bracewell RN, 1986, FOURIER TRANSFORM IT, P31999
[4]   A NOTE ON THE APPLICATION OF THE HILBERT TRANSFORM TO TIME-DELAY ESTIMATION [J].
CABOT, RC .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1981, 29 (03) :607-609
[5]   3-D correlation-based speckle tracking [J].
Chen, X ;
Xie, H ;
Erkamp, R ;
Kim, K ;
Jia, C ;
Rubin, JM ;
O'Donnell, M .
ULTRASONIC IMAGING, 2005, 27 (01) :21-36
[6]   Lateral speckle tracking using synthetic lateral phase [J].
Chen, XC ;
Zohdy, MJ ;
Emelianov, SY ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (05) :540-550
[7]   PULSED DOPPLER ACCURACY ASSESSMENT DUE TO FREQUENCY-DEPENDENT ATTENUATION AND RAYLEIGH-SCATTERING ERROR SOURCES [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :322-326
[8]  
FFMI C, 2002, TECHNICAL REPORT JAP, P37
[9]   FLOW VELOCITY PROFILE VIA TIME-DOMAIN CORRELATION ERROR ANALYSIS AND COMPUTER-SIMULATION [J].
FOSTER, SG ;
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :164-175
[10]   MULTIPLE CROSSED-BEAM ULTRASOUND DOPPLER VELOCIMETRY [J].
FOX, MD .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (05) :281-286