Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement

被引:2
作者
Vallabhaneni, Srilakshmi [1 ]
Matka, Marsel [1 ]
Modi, Vivek [1 ]
Carey, Matthew [2 ]
Sarnoski, Christopher [3 ]
Durkin, Raymond [3 ]
Olenchock, Stephen [4 ]
Razzaghi, Mehdi [5 ]
Shirani, Jamshid [1 ]
机构
[1] St Lukes Univ Hlth Network, Cardiol, Bethlehem, PA 18015 USA
[2] St Lukes Univ Hlth Network, Internal Med, Bethlehem, PA USA
[3] St Lukes Univ Hlth Network, Intervent Cardiol, Bethlehem, PA USA
[4] St Lukes Univ Hlth Network, Cardiac Surg, Bethlehem, PA USA
[5] Bloomsburg Univ Penn, Stat, Bloomsburg, PA 17815 USA
关键词
aortic stenosis; transcatheter aortic valve replacement; patient prosthesis mismatch; outcomes; edwards sapien valve; HIGH-RISK PATIENTS; CLINICAL IMPACT; STENOSIS; IMPLANTATION; PREDICTORS; SURVIVAL; OUTCOMES; TRIAL;
D O I
10.7759/cureus.18044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 +/- 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Overestimation of Paravalvular Leak With Edwards SAPIEN 3 Transcatheter Aortic Valve Replacement
    Kobayashi, Taisei
    Giri, Jay
    Vallabhajosyula, Prashanth
    Herrmann, Howard C.
    Jagasia, Dinesh H.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (05) : E69 - E71
  • [32] Transcarotid Approach for Transcatheter Aortic Valve Replacement With the Sapien 3 Prosthesis A Multicenter French Registry
    Overtchouk, Pavel
    Folliguet, Thierry
    Pinaud, Frederic
    Fouquet, Oliver
    Pernot, Mathieu
    Bonnet, Guillaume
    Hubert, Maxime
    Lapeze, Joel
    Claudel, Jean Philippe
    Ghostine, Said
    Azmoun, Alexandre
    Caussin, Christophe
    Zannis, Konstantinos
    Harmouche, Majid
    Verhoye, Jean-Philippe
    Lafont, Antoine
    Chamandi, Chekrallah
    Ruggieri, Vito Giovanni
    Di Cesare, Alessandro
    Leclercq, Florence
    Gandet, Thomas
    Modine, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (05) : 413 - 419
  • [33] Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry
    Herrmann, Howard C.
    Daneshvar, Samuel A.
    Fonarow, Gregg C.
    Stebbins, Amanda
    Vemulapalli, Sreekanth
    Desai, Nimesh D.
    Malenka, David J.
    Thourani, Vinod H.
    Rymer, Jennifer
    Kosinski, Andrzej S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2701 - 2711
  • [34] Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves Comparison of SAPIEN 3 Ultra Versus SAPIEN 3
    Rheude, Tobias
    Pellegrini, Costanza
    Lutz, Jannik
    Alvarez-Covarrubias, Hector A.
    Lahmann, Anna Lena
    Mayr, N. Patrick
    Michel, Jonathan
    Kasel, Markus A.
    Joner, Michael
    Xhepa, Erion
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (22) : 2631 - 2638
  • [35] Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis
    Gonska, Birgid
    Seeger, Julia
    Junker, Alexander
    Rodewald, Christoph
    Trepte, Ulrike
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    Woehrle, Jochen
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (8-9) : 470 - 479
  • [36] Incidence and Severity of Paravalvular Aortic Regurgitation With Multidetector Computed Tomography Nominal Area Oversizing or Undersizing After Transcatheter Heart Valve Replacement With the Sapien 3 A Comparison With the Sapien XT
    Yang, Tae-Hyun
    Webb, John G.
    Blanke, Philipp
    Dvir, Danny
    Hansson, Nicolaj C.
    Norgaard, Bjarne L.
    Thompson, Christopher R.
    Thomas, Martyn
    Wendler, Olaf
    Vahanian, Alec
    Himbert, Dominique
    Kodali, Susheel K.
    Hahn, Rebecca T.
    Thourani, Vinod H.
    Schymik, Gerhard
    Precious, Bruce
    Berger, Adam
    Wood, David A.
    Pibarot, Philippe
    Rodes-Cabau, Josep
    Jaber, Wael A.
    Leon, Martin B.
    Walther, Thomas
    Leipsic, Jonathon
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (03) : 462 - 471
  • [37] Aortic regurgitation after transcatheter aortic valve implantation of the edwards SAPIEN™ valve
    Nielsen, Hans Henrik Moller
    Egeblad, Henrik
    Andersen, Henning Rud
    Thuesen, Leif
    Poulsen, Steen Hvitfeldt
    Klaaborg, Kaj-Erik
    Jakobsen, Carl-Johan
    Hjortdal, Vibeke Elisabeth
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2013, 47 (01) : 36 - 41
  • [38] Reducing Prosthesis-Patient Mismatch With Edwards Magna Prosthesis for Aortic Valve Replacement
    Kume, Yuta
    Fujita, Tomoyuki
    Fukushima, Satsuki
    Hata, Hiroki
    Shimahara, Yusuke
    Matsumoto, Yorihiko
    Yamashita, Kizuku
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2017, 81 (04) : 468 - 475
  • [39] Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry
    Romano, Mauro
    Frank, Derk
    Cocchieri, Riccardo
    Jagielak, Dariusz
    Bonaros, Nikolaos
    Aiello, Marco
    Lapeze, Joel
    Laine, Mika
    Chocron, Sidney
    Muir, Douglas
    Eichinger, Walter
    Thielmann, Matthias
    Labrousse, Louis
    Rein, Kjell Arne
    Verhoye, Jean-Philippe
    Gerosa, Gino
    Baumbach, Hardy
    Deutsch, Cornelia
    Bramlage, Peter
    Thoenes, Martin
    Bapat, Vinayak
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (05) : 757 - 764
  • [40] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185