Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement

被引:2
|
作者
Vallabhaneni, Srilakshmi [1 ]
Matka, Marsel [1 ]
Modi, Vivek [1 ]
Carey, Matthew [2 ]
Sarnoski, Christopher [3 ]
Durkin, Raymond [3 ]
Olenchock, Stephen [4 ]
Razzaghi, Mehdi [5 ]
Shirani, Jamshid [1 ]
机构
[1] St Lukes Univ Hlth Network, Cardiol, Bethlehem, PA 18015 USA
[2] St Lukes Univ Hlth Network, Internal Med, Bethlehem, PA USA
[3] St Lukes Univ Hlth Network, Intervent Cardiol, Bethlehem, PA USA
[4] St Lukes Univ Hlth Network, Cardiac Surg, Bethlehem, PA USA
[5] Bloomsburg Univ Penn, Stat, Bloomsburg, PA 17815 USA
关键词
aortic stenosis; transcatheter aortic valve replacement; patient prosthesis mismatch; outcomes; edwards sapien valve; HIGH-RISK PATIENTS; CLINICAL IMPACT; STENOSIS; IMPLANTATION; PREDICTORS; SURVIVAL; OUTCOMES; TRIAL;
D O I
10.7759/cureus.18044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 +/- 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Transient and persistent conduction abnormalities following transcatheter aortic valve replacement with the Edwards-Sapien prosthesis: a comparison between antegrade vs. retrograde approaches
    Sager, Solomon J.
    Damluji, Abdulla A.
    Cohen, Joshua A.
    Shah, Sachil
    O'Neill, Brian P.
    Alfonso, Carlos E.
    Martinez, Claudia A.
    Myerburg, Robert J.
    Heldman, Alan W.
    Cohen, Mauricio G.
    Williams, Donald B.
    Carrillo, Roger G.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (02) : 143 - 151
  • [22] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122
  • [23] Transfemoral Aortic Valve Replacement With the Edwards SAPIEN and Edwards SAPIEN XT Prosthesis Using Exclusively Local Anesthesia and Fluoroscopic Guidance Feasibility and 30-Day Outcomes
    Durand, Eric
    Borz, Bogdan
    Godin, Matthieu
    Tron, Christophe
    Litzler, Pierre-Yves
    Bessou, Jean-Paul
    Bejar, Karim
    Fraccaro, Chiara
    Sanchez-Giron, Carlos
    Dacher, Jean-Nicolas
    Bauer, Fabrice
    Cribier, Alain
    Eltchaninoff, Helene
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 461 - 467
  • [24] Standardized Methodology for Transfemoral Transcatheter Aortic Valve Replacement With the Edwards Sapien XT Valve Under Fluoroscopy Guidance
    Kasel, Albert M.
    Shivaraju, Anupama
    Schneider, Stephan
    Krapf, Stephan
    Oertel, Frank
    Burgdorf, Christof
    Ott, Ilka
    Sumer, Christian
    Kastrati, Adnan
    von Scheidt, Wolfgang
    Thilo, Christian
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (09) : 451 - 461
  • [25] Incidence and Implications of Idiopathic Thrombocytopenia Following Transcatheter Aortic Valve Replacement With the Edwards Sapien© Valves: A Single Center Experience
    McCabe, James M.
    Huang, Pei-Hsiu
    Riedl, Lauren A.
    Devireddy, Srikanth R.
    Grondell, Jennifer
    Connors, Annie C.
    Davidson, Michael J.
    Eisenhauer, Andrew C.
    Welt, Frederick G. P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (04) : 633 - 641
  • [26] Surgical Aortic Valve Replacement Following Early Sapien-XT Valve Failure: A First
    Ahmad, Tanveer
    Ludhani, Prakash
    Gurvitch, Ronen
    Goldblatt, John
    Tatoulis, James
    HEART LUNG AND CIRCULATION, 2018, 27 (04) : 513 - 516
  • [27] Transcatheter aortic valve replacement with the SAPIEN 3 valve: preparing the field for the final expansion
    Paradis, Jean-Michel
    Rodes-Cabau, Josep
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2017, 7 (01) : 11 - 15
  • [28] Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses
    Eltchaninoff, Helene
    Durand, Eric
    Borz, Bogdan
    Godin, Matthieu
    Tron, Christophe
    Litzler, Pierre-Yves
    Bessou, Jean-Paul
    Bejar, Karim
    Fraccaro, Chiara
    Sanchez-Giron, Carlos
    Dacher, Jean-Nicolas
    Bauer, Fabrice
    Cribier, Alain
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (03) : 132 - 140
  • [29] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prostheses
    Okuno, Taishi
    Khan, Faisal
    Asami, Masahiko
    Praz, Fabien
    Heg, Dik
    Winkel, Mirjam Gauri
    Lanz, Jonas
    Huber, Adrian
    Grani, Christoph
    Raber, Lorenz
    Stortecky, Stefan
    Valgimigli, Marco
    Windecker, Stephan
    Pilgrim, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2173 - 2182
  • [30] Newer-generation of Edwards transcatheter aortic valve systems: SAPIEN 3, Centera, and SAPIEN 3 Ultra
    Solomonica, Amir
    Choudhury, Tawfiq
    Bagur, Rodrigo
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (02) : 81 - 87