Use of ion-molecule reactions and methanol addition to improve arsenic determination in high chlorine food samples by DRC-ICP-MS

被引:35
作者
Guo, Wei [1 ,2 ]
Hu, Shenghong [1 ]
Li, Xiaofang [2 ]
Zhao, Jian [2 ]
Jin, Shesheng [2 ]
Liu, Wenjuan [2 ]
Zhang, Hongfei [1 ]
机构
[1] China Univ Geosci, Fac Earth Sci, Minist Educ, Key Lab Biogeol & Environm Geol, Wuhan 430074, Hubei, Peoples R China
[2] Minist Commerce, Circulat Ind Promot Ctr, Beijing 100747, Peoples R China
关键词
Ion-molecule reactions; Methanol addition; Arsenic; High chlorine food samples; DRC-ICP-MS; PLASMA-MASS-SPECTROMETRY; DYNAMIC REACTION CELL; ATOMIC-ABSORPTION-SPECTROMETRY; HYDRIDE GENERATION; SPECTRAL INTERFERENCES; EMISSION-SPECTROMETRY; SPECIATION ANALYSIS; NATURAL-WATER; TRACE CADMIUM; EXTRACTION;
D O I
10.1016/j.talanta.2011.02.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct determination of trace arsenic in high chlorine food samples by ICP-MS is complicated by the presence of ArCl(+) interferences, and the high first ionization energy of As (9.81 eV) also results in low analytical sensitivity in ICP-MS. In this work, two strategies based on ion-molecule reactions were successfully used to eliminate ArCl spectral interference in a dynamic reaction cell (DRC). The interference ion ((40)Ar(35)Cl(+)) was directly removed by the reaction with methane gas, and the background signal was reduced by up to 100-fold at m/z 75. Alternatively, by using molecule oxygen as the reaction gas, (75)As(+) was effectively converted to (75)As(16)O(+) that could be detected at m/z 91 where the background is low. The poor signal intensity of As or AsO was improved 3-4 times by addition of 4% methanol in the analyzed solutions. The limit of quantitation (LOQ) for (75)As (CH(4)-DRC method) and (75)As(16)O (O(2)-DRC method) was 0.8 and 0.3 ng g(-1) and the analytical results of seaweed and yellow croaker standard reference materials were in good agreement with the certified values. As the routine arsenic monitoring method in our laboratory, it was applied to the accuracy determination of 119 high chlorine food samples from eight different markets of Beijing. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:887 / 894
页数:8
相关论文
共 42 条
[1]   Direct sample introduction of wines in graphite furnace atomic absorption spectrometry for the simultaneous determination of arsenic, cadmium, copper and lead content [J].
Ajtony, Zsolt ;
Szoboszlai, Norbert ;
Susko, Emoke Klaudia ;
Mezei, Pal ;
Gyoergy, Krisztina ;
Bencs, Laszlo .
TALANTA, 2008, 76 (03) :627-634
[2]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[3]   Detection of arsenic-containing hydrocarbons in canned cod liver tissue [J].
Arroyo-Abad, Uriel ;
Mattusch, Juergen ;
Mothes, Sibylle ;
Moeder, Monika ;
Wennrich, Rainer ;
Elizalde-Gonzalez, Maria P. ;
Matysik, Frank-Michael .
TALANTA, 2010, 82 (01) :38-43
[4]   Open digestion under reflux for the determination of total arsenic in seafood by inductively coupled plasma atomic emission spectrometry with hydride generation [J].
Boutakhrit, K ;
Claus, R ;
Bolle, F ;
Degroodt, JM ;
Goeyens, L .
TALANTA, 2005, 66 (04) :1042-1047
[5]   Sample matrix and critical interference effects on the recovery and accuracy of concentration measurements of arsenic in ambient particulate samples using ICP-MS [J].
Brown, RJC ;
Yardley, RE ;
Brown, AS ;
Milton, MJT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (05) :703-705
[6]   A comparative study of chemical modifiers in the determination of total arsenic in marine food by tungsten coil electrothermal atomic absorption spectrometry [J].
Bruhn, Carlos G. ;
Bustos, Catherine J. ;
Saez, Katia L. ;
Neira, Jose Y. ;
Alvarez, Solange E. .
TALANTA, 2007, 71 (01) :81-89
[7]   Measurements of contaminant elements of wines by inductively coupled plasma-mass spectrometry: A comparison of two calibration approaches [J].
Catarino, Sofia ;
Curvelo-Garcia, A. S. ;
de Sousa, R. Bruno .
TALANTA, 2006, 70 (05) :1073-1080
[8]   Arsenic speciation in freshwater fish: Focus on extraction and mass balance [J].
Ciardullo, Silvia ;
Aureli, Federica ;
Raggi, Andrea ;
Cubadda, Francesco .
TALANTA, 2010, 81 (1-2) :213-221
[9]   Evaluation of a desolvating microconcentric nebulizer in inductively coupled plasma mass spectrometry to improve the determination of arsenic in steels [J].
Coedo, AG ;
Dorado, T ;
Padilla, I .
APPLIED SPECTROSCOPY, 1999, 53 (08) :974-978
[10]   Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system [J].
D'Ilio, S. ;
Violante, N. ;
Di Gregorio, M. ;
Senofonte, O. ;
Petrucci, F. .
ANALYTICA CHIMICA ACTA, 2006, 579 (02) :202-208